Voltronic Axpert VM 4 5600-48 Off-Grid Solar Inverter
- Rated Power:3600VA/3600W
- Selectable Voltage Range:170-280 VAC (For Personal Computers); 90-280 VAC (For Home…

The Axpert VM 4 3600-24 is an off-grid solar inverter rated Axpert VM 4 3600-24.
In stock
The Axpert VM 4 3600-24 is an off-grid solar inverter rated Axpert VM 4 3600-24. Every figure on this page is read from the manufacturer's manual for the Axpert VM series.
Specifications last updated 18 August 2026
| Rated Power | 3600VA/3600W |
|---|---|
| Selectable Voltage Range | 170-280 VAC (For Personal Computers); 90-280 VAC (For Home Appliances) |
| Efficiency (Peak) | 90% 93% |
| Maximum PV Array Power | 4000W |
| Communication Interface | USB/RS232/RS485/WiFi/Dry-contact |
| Surge Power | 7200VA |
| Floating Charge Voltage | 27 VDC |
| Solar Charger Type | MPPT |
| Maxmum Solar Charge Current | 120 A |
| Maximum AC Charge Current | 100 A |
| Waveform | Pure sine wave |
| AC Voltage Regulation (Batt. Mode) | 230 VAC ± 5% |
| Transfer Time | 15 ms (For Personal Computers) ; 20 ms (For Home Appliances) |
| Maximum PV Array Open Circuit Voltage | 500 VDC |
| Net Weight (kgs) | 10.0 |
|---|
| Humidity | 5% to 95% |
|---|---|
| Operating Temperature | -10°C to 50°C |
| Storage Temperature | -15°C to 60°C |








Choose the right solar inverter for your UAE home. Compare grid-tie, hybrid, and off-grid inverters. DEWA Shams Dubai compliance and net metering explained.
Read: Solar Inverters for UAE Homes: Grid-Tie, Hybrid, and Off-Grid Options →Compare Voltronic Axpert and Must Solar off-grid inverters. Build quality, specifications, parallel capability, support network, and long-term value.
Read: Voltronic Axpert vs Must Solar Inverters: Which Platform Wins? →Set up WiFi monitoring for Voltronic Axpert, InfiniSolar, and UPS systems. App configuration, cloud dashboard, alerts, and troubleshooting tips.
Read: How to Monitor Voltronic Inverters and UPS via WiFi →The Axpert VM 4 3600-24 is rated 3600VA/3600W continuous, with 7200VA available on surge for the second a motor or a compressor starts. Size the load you actually intend to run against the continuous figure, never against the surge one.
The Axpert VM 4 3600-24 takes up to 4000W of PV array. The string has to stay below 500 VDC open-circuit — that ceiling is reached on a cold bright morning, not at noon.
Peak efficiency is 90% 93%. Whatever is not converted leaves as heat, so the Axpert VM 4 3600-24 needs clear air around it and a mounting spot that is not the hottest wall in the building.