Voltronic Axpert V PF1 1KVA Solar Inverter
- Input Voltage Waveform:Sinusoidal (utility or generator)
- Low Loss Voltage:90Vac±7V (Appliances)

The Axpert V PF1 2KVA is a solar inverter rated 2KVA. Every figure on this page is read from the manufacturer's manual for the Axpert V PF1 series.
In stock
The Axpert V PF1 2KVA is a solar inverter rated 2KVA. Every figure on this page is read from the manufacturer's manual for the Axpert V PF1 series.
Specifications last updated 17 August 2026
| Input Voltage Waveform | Sinusoidal (utility or generator) |
|---|---|
| Low Loss Voltage | 90Vac±7V (Appliances) |
| High Loss Voltage | 280Vac±7V |
| High Loss Return Voltage | 270Vac±7V |
| Max AC Input Voltage | 300Vac |
| Nominal Input Frequency | 50Hz/60Hz (Auto detection) |
| Low Loss Frequency | 40±1Hz |
| Low Loss Return Frequency | 42±1Hz |
| High Loss Frequency | 65±1Hz |
| High Loss Return Frequency | 63±1Hz |
| Output Short Circuit Protection | Circuit Breaker |
| Efficiency (Line Mode) | >95% (Rated R load |
| Transfer Time | 10ms typical (UPS); |
| LCD Display | Current mode / |
| Output | 500M |
| Floating Charging Voltage | 27Vdc |
| Nominal DC Input Voltage | 12Vdc |
| High DC Cut-off Voltage | 16Vdc |
| No Load Power Consumption | <25W |
| Nominal Input Voltage | 230Vac |
| Low Loss Return Voltage | 180Vac± 7V (UPS); 100Vac± 7V (Appliances) |
| Peak Efficiency | 93% |
| Surge Capacity | 2* rated power for 5 seconds |
| Maximum charging current | 80A |
| Overcharge | 30Vdc |
| Max. PV Array Open Circuit Voltage | 145Vdc |
| Max Charging Current | 140A |
| Line Mode Efficiency | 94.0 |
| Bulk Charging Voltage | 58.4 |
| Max. PV Array Power | 5000W |
| Operating Temperature Range | -10°C to 50°C |
|---|---|
| Storage temperature | -15°C~ 60°C |








Choose the right solar inverter for your UAE home. Compare grid-tie, hybrid, and off-grid inverters. DEWA Shams Dubai compliance and net metering explained.
Read: Solar Inverters for UAE Homes: Grid-Tie, Hybrid, and Off-Grid Options →Compare Voltronic Axpert and Must Solar off-grid inverters. Build quality, specifications, parallel capability, support network, and long-term value.
Read: Voltronic Axpert vs Must Solar Inverters: Which Platform Wins? →Set up WiFi monitoring for Voltronic Axpert, InfiniSolar, and UPS systems. App configuration, cloud dashboard, alerts, and troubleshooting tips.
Read: How to Monitor Voltronic Inverters and UPS via WiFi →The Axpert V PF1 2KVA takes up to 5000W of PV array. The string has to stay below 145Vdc open-circuit — that ceiling is reached on a cold bright morning, not at noon.
-10°C to 50°C. In a Gulf summer that is the figure that decides whether the unit goes in a ventilated room or on an unshaded wall.