Voltronic Axpert MAX TRI 12K Off-Grid Solar Inverter
- Parallel Capability:YES, 6 units
- Selectable Voltage Range:170-280 VAC (For Personal Computers)

The Axpert MAX TRI 11K is an off-grid solar inverter rated Axpert MAX TRI 11K.
In stock
The Axpert MAX TRI 11K is an off-grid solar inverter rated Axpert MAX TRI 11K. Every figure on this page is read from the manufacturer's manual for the Axpert MAX TRI series.
Specifications last updated 18 August 2026
| Parallel Capability | YES, 6 units |
|---|---|
| Selectable Voltage Range | 170-280 VAC (For Personal Computers) |
| Efficiency (Peak) | 93% |
| Maximum PV Array Power | 12000W (6000W x 2) |
| Maximum PV Input Current | 27A x 2 (MAX 40A) |
| Maxmum Solar Charge Current | 40A/27A (MAX 60A) |
| Communication Interface | USB/RS232/RS485/WiFi/Dry-contact |
| Capacity | 11000VA/11000W |
| Surge Power | 22000VA |
| Compliance Safety | IEC 62109, IEC 61683, EN/IEC 61000-6-2, 61000-6-4, 61000-3-11, 61000-3-12 |
| Floating Charge Voltage | 54 VDC |
| Maximum AC Charge Current | 150 A |
| Waveform | Pure sine wave |
| AC Voltage Regulation (Batt. Mode) | 230 VAC ± 5% |
| Transfer Time | 10 ms (For Personal Computers) 20 ms (For Home Appliances) |
| Solar Charger Type | MPPT |
| Maximum PV Array Open Circuit Voltage | 500 VDC |
| Frequency Range | 50 Hz/60 Hz (Auto sensing) |
| Battery Voltage | 48 VDC |
| Overcharge Protection | 63 VDC |
| MPPT Range @ Operating Voltage | 90 – 450 VDC |
| Net Weight (kgs) | 18.5 |
|---|
| Humidity | 5% to 95% |
|---|---|
| Operating Temperature | -10°C to 50°C |
| Storage Temperature | -15°C to 60°C |








Choose the right solar inverter for your UAE home. Compare grid-tie, hybrid, and off-grid inverters. DEWA Shams Dubai compliance and net metering explained.
Read: Solar Inverters for UAE Homes: Grid-Tie, Hybrid, and Off-Grid Options →Compare Voltronic Axpert and Must Solar off-grid inverters. Build quality, specifications, parallel capability, support network, and long-term value.
Read: Voltronic Axpert vs Must Solar Inverters: Which Platform Wins? →Set up WiFi monitoring for Voltronic Axpert, InfiniSolar, and UPS systems. App configuration, cloud dashboard, alerts, and troubleshooting tips.
Read: How to Monitor Voltronic Inverters and UPS via WiFi →The Axpert MAX TRI 11K takes up to 12000W (6000W x 2) of PV array. The string has to stay below 500 VDC open-circuit — that ceiling is reached on a cold bright morning, not at noon. The tracker works over 90 – 450 VDC, so wire the modules to land inside that window.
The Axpert MAX TRI 11K works with a 48 VDC bank. It charges at up to 40A/27A (MAX 60A), and that current — not the bank's capacity — is what the cabling and the fuse between bank and unit have to be sized for.
Peak efficiency is 93%. Whatever is not converted leaves as heat, so the Axpert MAX TRI 11K needs clear air around it and a mounting spot that is not the hottest wall in the building.