| Parallel Capability | YES, 12 units |
|---|---|
| Selectable Voltage Range | 170-280 VAC (For Personal Computers) |
| AC Voltage Regulation (Batt. Mode) | 230VAC ± 5% |
| Efficiency (Peak) | 93% |
| Communication Interface | USB/RS232/RS485/WiFi/Dry-contact |
| Rated Power | 11000VA/11000W |
| Surge Power | 22000VA |
| Maximum PV Array Power | 13000W (6500W x 2) |
| Maxmum Solar Charge Current | 150A |
| Maximum AC Charge Current | 150A |
| Maximum Charge Current | 150A |
| Floating Charge Voltage | 54 VDC |
| Maximum PV Input Current | 27A x 2 (MAX 40A) |
| Waveform | Pure sine wave |
| Solar Charger Type | MPPT |
| Maximum PV Array Open Circuit Voltage | 500 VDC |
| Humidity | 5% to 95% |
|---|---|
| Operating Temperature | -10°C to 50°C |
| Storage Temperature | -15°C to 60°C |








Choose the right solar inverter for your UAE home. Compare grid-tie, hybrid, and off-grid inverters. DEWA Shams Dubai compliance and net metering explained.
Read: Solar Inverters for UAE Homes: Grid-Tie, Hybrid, and Off-Grid Options →Compare Voltronic Axpert and Must Solar off-grid inverters. Build quality, specifications, parallel capability, support network, and long-term value.
Read: Voltronic Axpert vs Must Solar Inverters: Which Platform Wins? →Set up WiFi monitoring for Voltronic Axpert, InfiniSolar, and UPS systems. App configuration, cloud dashboard, alerts, and troubleshooting tips.
Read: How to Monitor Voltronic Inverters and UPS via WiFi →The Axpert MAX II TWIN HMI 11K is rated 11000VA/11000W continuous, with 22000VA available on surge for the second a motor or a compressor starts. Size the load you actually intend to run against the continuous figure, never against the surge one.
The Axpert MAX II TWIN HMI 11K takes up to 13000W (6500W x 2) of PV array. The string has to stay below 500 VDC open-circuit — that ceiling is reached on a cold bright morning, not at noon.
Peak efficiency is 93%. Whatever is not converted leaves as heat, so the Axpert MAX II TWIN HMI 11K needs clear air around it and a mounting spot that is not the hottest wall in the building.