Technical Specifications
| Parameter | AXPERT-KING-II-TWIN-6KW | VOLTRONIC-AXPERT-KING-II-TWIN | AXPERT-KING-II-TWIN-6.2K | AXPERT-KING-II-TWIN-6K |
|---|---|---|---|---|
| Additional Specifications | ||||
| Input Voltage Waveform | Sinusoidal | |||
| Nominal Input Voltage | 230Vac | |||
| Low Loss Voltage | 176Vac±7V | |||
| Low Loss Return Voltage | 186Vac+7V | |||
| High Loss Voltage | 280Vac±7V | |||
| High Loss Return Voltage | 270Vac±7V | |||
| Max AC Input Voltage | 300Vac | |||
| Nominal Input Frequency | 50Hz/60Hz (Auto detection) | |||
| Low Loss Frequency | 46(56)±1Hz | |||
| Low Loss Return Frequency | 46.5(57)±1Hz | |||
| High Loss Frequency | 54(64)±1Hz | |||
| High Loss Return Frequency | 6KW | |||
| Power Factor | >0.98 | |||
| Efficiency (Line Mode) | 93% ( | |||
| Floating Charging Voltage | 54Vdc | |||
| Communication | RS232 and Wi-Fi | |||
| Bypass Mode | 6KW | |||
| Voltage Range | 110-280 VAC | |||
| Output Short Circuit Protection | Line mode: Circuit Breaker Battery mode: Electronic Circuits | |||
| Surge Capacity | 2* rated power for 5 seconds | |||
| Nominal DC Input Voltage | 48Vdc | |||
| No Load Power Consumption | <75W | |||
| Max. PV Array Open Circuit Voltage | 500Vdc | |||
| Safety Certification | CE | |||
| Floating Charge Voltage | 54 VDC | |||
| Maximum PV Array Open Circuit Voltage | 500 VDC | |||
| Maxmum Solar Charge Current | 120A | |||
| AC Output | ||||
| Transfer Time | Inverter-to-bypass 4ms | 0 ms | Inverter-to-bypass 4ms | Inverter-to-bypass 4ms |
| Waveform | Pure sine wave | |||
| PARALLEL CAPABILITY | Up to 9 units | |||
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz | |||
| Time Inverter to Bypass | 4 ms (Typical) | |||
| Battery Input | ||||
| Overcharge Protection | 66Vdc | 66 VDC | 66Vdc | 66Vdc |
| Battery Voltage | 40–66 VDC | |||
| Efficiency | ||||
| Line Mode | 94% | |||
| Battery Mode | 92% | |||
| ECO Mode | 98% | |||
| PV Input | ||||
| Maximum AC Charge Current | 120A | 120A / 120A | 120A | 120A |
| Solar Charger type | MPPT | |||
| Maximum PV Array Power | 6000 W | |||
| MPPT Range @ Operating Voltage | 120 – 430 VDC | |||
| Maximum Solar Charge Current | 120A / 120A | |||
| Operating Conditions | ||||
| Storage Temperature | -15°C~ 60°C | -15°C to 60°C | — | -15°C to 60°C |
| Humidity | 5% to 95% | 5% to 95% Relative Humidity(Non-condensing) | 5% to 95% | 5% to 95% |
| Operating Temperature | -10°C to 50°C | |||
| Electrical Data | ||||
| RATED POWER | — | 6000VA/6000W / 6200VA/6200W | 6200VA/6200W | 6000VA/6000W |
| AC Voltage Regulation (Line&Batt. Mode) | — | 230VAC ± 5% | 230VAC ±5% | 230VAC ±5% |
| Frequency Range (Synchronized Range) | — | 46–54 Hz or 56–64 Hz | 46-54 Hz or 56-64 Hz | 46-54 Hz or 56-64 Hz |
| Harmonic Distortion | — | ≤ 3 % THD (Linear Load); ≤ 5 % THD (Non-linear Load) | ≤3% THD (Linear Load); ≤ 5% THD (Non-linear Load) | ≤3% THD (Linear Load); ≤ 5% THD (Non-linear Load) |
| Communication | ||||
| Communication Interface | — | RS232, USB, Dry contact, WI-FI, RS485 | RS232, USB | RS232, USB |
| Mechanical Data | ||||
| Dimension, D x W x H (mm) | 140 x 295 x 468 | |||
| Net Weight (kgs) | 12 | |||
| Electrical / AC Output Data | ||||
| THDi | ≤ 10% | |||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- Dual outputs, for smart load: Dual outputs, for smart load management
- Maximum PV input current increases: Maximum PV input current increases to 27A
- Zero (0ms) transfer time to: Zero (0ms) transfer time to protect mission-critical loads such as servers and ATMs
- High PV input voltage range
- Detachable LCD control module with: Detachable LCD control module with multiple communications
- Selectable high power charging current
- Built-in Wi-Fi for mobile monitoring: Built-in Wi-Fi for mobile monitoring (App is available)
- Configurable AC/Solar input priority via: Configurable AC/Solar input priority via LCD setting
- Reserved communication port for BMS: Reserved communication port for BMS (RS485 or CAN-BUS)
- USB On-the-Go function
- Parallel operation up to 9: Parallel operation up to 9 units
Frequently Asked Questions
What voltage range does the Voltronic Solar Charge Controller Axpert KING II TWIN 6KW accept?
The Voltronic Solar Charge Controller Axpert KING II TWIN 6KW accepts an input voltage range of 110-280 VAC.
What is the operating temperature range of the Voltronic Solar Charge Controller Axpert KING II TWIN 6KW?
The Voltronic Solar Charge Controller Axpert KING II TWIN 6KW operates across -10°C to 50°C and a humidity range of 5% to 95%.
What is the efficiency of the Voltronic Solar Charge Controller Axpert KING II TWIN 6KW?
The Voltronic Solar Charge Controller Axpert KING II TWIN 6KW has an efficiency of 93% (.
What solar input can the Voltronic Solar Charge Controller Axpert KING II TWIN 6KW handle?
The Voltronic Solar Charge Controller Axpert KING II TWIN 6KW supports a maximum PV array power of 6000 W and a maximum PV array open-circuit voltage of 500 VDC.
What is the maximum charge current of the Voltronic Solar Charge Controller Axpert KING II TWIN 6KW?
The Voltronic Solar Charge Controller Axpert KING II TWIN 6KW has a maximum charge current of 120A.
What transfer time and output waveform does the Voltronic Solar Charge Controller Axpert KING II TWIN 6KW provide?
The Voltronic Solar Charge Controller Axpert KING II TWIN 6KW has a transfer time of inverter-to-bypass 4ms and an output waveform of Sinusoidal.
What is the power quality of the Voltronic Solar Charge Controller Axpert KING II TWIN 6KW?
The Voltronic Solar Charge Controller Axpert KING II TWIN 6KW has a power factor of >0.98.
What certifications does the Voltronic Solar Charge Controller Axpert KING II TWIN 6KW have?
The Voltronic Solar Charge Controller Axpert KING II TWIN 6KW is certified to CE, meeting recognised international standards for safety and performance.
What warranty coverage is available for the Voltronic Solar Charge Controller Axpert KING II TWIN 6KW?
The Voltronic Solar Charge Controller Axpert KING II TWIN 6KW is backed by a 2-year manufacturer warranty from Voltronic Power.
What is the rated power of the Voltronic 6.2 kW Off-Grid Solar Inverter Axpert King II TWIN?
The Voltronic 6.2 kW Off-Grid Solar Inverter Axpert King II TWIN has a rated power of 6000 VA/6000W / 6200 VA/6200W.