Voltronic Power Solar Inverter Datasheet — INFINISOLAR-WP-LV-PREMIUM-PREMIUM12KW
The InfiniSolar WP LV Premium Premium12KW is a solar inverter rated Premium12KW.
SKU: INFINISOLAR-WP-LV-PREMIUM-PREMIUM12KW | Last Updated: 2026-08-18
⚡Electrical Specifications
| Nominal Output Current | 41.7A per phase |
| Efficiency (DC to AC) | 91% |
| Maximum DC Power | 12000 W |
| Nominal DC Voltage | 48 VDC |
| Maximum DC Voltage | 600 VDC |
| Working DC Voltage Range | 120 VDC ~ 550 VDC |
| Start-up Voltage / Initial Feeding Voltage | 125 VDC / 160 VDC |
| Maximum Input Current | 2 x 18 A (MAX 30 A) |
| Isc PV (absolute maximum) | 2 x 18 A (MAX 30 A) |
| Nominal Output Voltage | 120 VAC (P-N) / 208 VAC (P-P)/ 240 VAC(P-P) |
| Inrush Current/Duration | 50 A per phase / 20ms |
| Maximum Output Fault Current/Duration | 90 A per phase / 1ms |
| Maximum Output Overcurrent Protection | 90 A per phase |
| AC Start-up Voltage | 85 VAC per phase |
| Auto Restart Voltage | 90 VAC per phase |
| Nominal Frequency | 50 Hz / 60 Hz |
| Maximum AC Input Current | 60 A |
| Inrush Input Current | 60 A / 1ms |
| Maximum Battery Discharging Current | 200 A |
| Maximum Charging Current | 200 A |
| Output Voltage Range | 105.5 VAC - 132 VAC (per phase) |
| Power Factor | 0.9 lag to 0.9 lead |
| Maximum Conversion Efficiency (DC/AC) | 96% |
| Safety | UL1741SA, UL1741SB, CSA 22.2.107.1, CEC |
| Grid Connection Standard | IEEE 1547.1:2020, IEEE 1547:2018, California Rule 21, HECO Rule 14H |
| EMC | FCC Part 15 Class B |
| PV DC Switch - NEC 690.15 | Yes |
🔧Mechanical Specifications
📏Dimensions
Width
Height
Depth
Weight49 kg