Voltronic Axpert MAX AIR 10K Off-Grid Solar Inverter
- AC Voltage Regulation (Batt. Mode):230VAC ±10%
- Efficiency (Peak):93%

The Axpert MAX AIR 12K is an off-grid solar inverter rated Axpert MAX AIR 12K.
In stock
The Axpert MAX AIR 12K is an off-grid solar inverter rated Axpert MAX AIR 12K. Every figure on this page is read from the manufacturer's manual for the Axpert MAX AIR series.
Specifications last updated 18 August 2026
| AC Voltage Regulation (Batt. Mode) | 230VAC ±10% |
|---|---|
| Efficiency (Peak) | 93% |
| Communication Interface | USB/RS232/RS485/WiFi/Dry-contact |
| Rated Power | 12000VA/12000W |
| Surge Power | 24000VA |
| Maximum PV Array Power | B000W |
| Maximum Solar Charge Current | 200A |
| Maximum AC Charge Current | 200A |
| Maximum PV Input Current | 30A x 2 (Max. 45A) |
| Waveform | Pure sine wave |
| Transfer Time | 10 ms (For Personal Computers) 20 ms (For Home Appliances) |
| Floating Charge Voltage | 54 VDC |
| Solar Charger type | MPPT |
| MPP Range @ Operating Voltage | 60 ~ 450 VDC |
| Maximum PV Array Open Circuit Voltage | 500 VDC |
| Net Weight (kgs) | 15.5 |
|---|
| Humidity | 5% to 95% |
|---|---|
| Operating Temperature | -10°C to 50°C |
| Storage Temperature | -15°C to 60°C |
| Ingress Protection | IP52 |








Everything you need to know before buying an off-grid inverter. Power rating, MPPT specs, battery options, warranty, and common mistakes to avoid.
Read: Off-Grid Inverter Buying Guide: What to Look For in 2026 →Choose the right solar inverter for your UAE home. Compare grid-tie, hybrid, and off-grid inverters. DEWA Shams Dubai compliance and net metering explained.
Read: Solar Inverters for UAE Homes: Grid-Tie, Hybrid, and Off-Grid Options →Compare Voltronic Axpert and Must Solar off-grid inverters. Build quality, specifications, parallel capability, support network, and long-term value.
Read: Voltronic Axpert vs Must Solar Inverters: Which Platform Wins? →The Axpert MAX AIR 12K is rated 12000VA/12000W continuous, with 24000VA available on surge for the second a motor or a compressor starts. Size the load you actually intend to run against the continuous figure, never against the surge one.
Peak efficiency is 93%. Whatever is not converted leaves as heat, so the Axpert MAX AIR 12K needs clear air around it and a mounting spot that is not the hottest wall in the building.
Over USB/RS232/RS485/WiFi/Dry-contact. Those are the ports this unit publishes, and any monitoring or logging you plan has to go through one of them.