Voltronic Power Axpert King II TWIN

Voltronic Axpert King II TWIN

Discover the Axpert King II TWIN inverter by Voltronic Power with 6000VA/6000W power and parallel capability for up to 9 units.

  • RATED POWER: 6000-6200 W
  • PARALLEL CAPABILITY: Up to 9 units
  • AC Voltage Regulation (Line&Batt. Mode): 230VAC ± 5%
  • Frequency Range: 46-64 Hz
2,700 AEDincl. VAT
Full Specifications

Features

Dual outputs, for smart load

Dual outputs, for smart load management

Maximum PV input current increases

Maximum PV input current increases to 27A

Zero (0ms) transfer time to

Zero (0ms) transfer time to protect mission-critical loads such as servers and ATMs

High PV input voltage range

Detachable LCD control module with

Detachable LCD control module with multiple communications

Selectable high power charging current

Built-in Wi-Fi for mobile monitoring

Built-in Wi-Fi for mobile monitoring (App is available)

Configurable AC/Solar input priority via

Configurable AC/Solar input priority via LCD setting

Reserved communication port for BMS

Reserved communication port for BMS (RS485 or CAN-BUS)

USB On-the-Go function

Parallel operation up to 9

Parallel operation up to 9 units

Overview

The Axpert King II TWIN by Voltronic Power is a high-performance inverter designed to meet demanding power needs. With a rated power of 6000VA/6000W and the ability to connect up to 9 units in parallel, it ensures reliable and efficient energy management. Ideal for residential and commercial applications, the Axpert King II TWIN is perfect for backup power systems, renewable energy setups, and off-grid installations.

Full specifications

Electrical

RATED POWER6000VA/6000W / 6200VA/6200W
PARALLEL CAPABILITYUp to 9 units
AC Voltage Regulation (Line&Batt. Mode)230VAC ± 5%
Frequency Range (Synchronized Range)46–54 Hz or 56–64 Hz
Frequency Range (Batt. Mode)50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
Harmonic Distortion≤ 3 % THD (Linear Load); ≤ 5 % THD (Non-linear Load)
Transfer Time0 ms
Time Inverter to Bypass4 ms (Typical)
WaveformPure sine wave
Line Mode94%
ECO Mode98%
Battery Voltage40–66 VDC
Floating Charge Voltage54 VDC
Overcharge Protection66 VDC
Solar Charger typeMPPT
Maximum PV Array Power6000 W
MPPT Range @ Operating Voltage120 – 430 VDC
Maximum PV Array Open Circuit Voltage500 VDC
Maximum Solar Charge Current120A / 120A
Maximum AC Charge Current120A / 120A
Communication InterfaceRS232, USB, Dry contact, WI-FI, RS485
Voltage Range110-280 VAC
Input Voltage WaveformSinusoidal
Low Loss Voltage176Vac±7V
Low Loss Return Voltage186Vac+7V
High Loss Voltage280Vac±7V
High Loss Return Voltage270Vac±7V
Max AC Input Voltage300Vac
Low Loss Frequency46(56)±1Hz
Low Loss Return Frequency46.5(57)±1Hz
Power Factor>0.98
Efficiency (Line Mode)93% (
Output Short Circuit ProtectionLine mode: Circuit Breaker Battery mode: Electronic Circuits
Battery Mode92%
Surge Capacity2* rated power for 5 seconds
Nominal DC Input Voltage48Vdc
No Load Power Consumption<75W
Safety CertificationCE

Mechanical

Dimension, D x W x H (mm)140 x 295 x 468
Net Weight (kgs)12

Environmental

Humidity5% to 95% Relative Humidity(Non-condensing)
Operating Temperature-10°C to 50°C
Storage Temperature-15°C to 60°C

Related Products