Voltronic Power UPS SOLAR-UPS-5KW

Discover Voltronic Power's Solar UPS 5KW with 230 VAC voltage, auto-sensing frequency, and precise voltage regulation for reliable power.

Models Covered: VOLTRONIC-SOLAR-UPS-5KW

Manufacturer: Voltronic Power Technology Corp.

Application: The Voltronic UPS Solar 5KW is a Single Phase Online UPS with a maximum PV array power of 4000 W, making it a dependable choice for protecting critical loads from power interruptions. It accepts an operating voltage range of 110-280 VAC. Its output waveform is Pure Sinewave. The unit measures 465 x 190 x 336 and weighs 16. It is rated to operate across -10°C to 50°C, with a humidity tolerance of 5% to 95% Relative Humidity(Non-condensing). Monitoring and control are available over RS232 & USB. The Voltronic UPS Solar 5KW is backed by a 2-year manufacturer warranty from Voltronic Power. Its published specifications also list Voltage of 230 VAC, Frequency Range (Synchronized Range) of 46-54 Hz or 56-64 Hz and Frequency Range (Batt. Mode) of 50 Hz.

Models and prices

Technical Specifications

Technical Specifications
ParameterVOLTRONIC-SOLAR-UPS-5KW
Input
Voltage230 VAC
Voltage Range110-280 VAC
Frequency Range50 Hz/60 Hz (Auto sensing) ± 4Hz
Power Factor> 0.98 @ Nominal Voltage (100% Load)
THDi< 10%
Output
AC Voltage Regulation (Batt. Mode)230VAC ± 5%
Frequency Range (Synchronized Range)46-54 Hz or 56-64 Hz
Frequency Range (Batt. Mode)50 Hz
Harmonic Distortion≤ 3% THD (Linear Load) ; ≤ 5 % THD (Non-linear Load)
Transfer Time0 ms
WaveformPure Sinewave
Efficiency
Line Mode93.0%
ECO Mode99.0%
Battery Mode90.0%
Battery
Battery Voltage48 VDC
Floating Charge Voltage54 VDC
Overcharge Protection66 VDC
Solar Charger & AC Charger
Solar Charger TypeMPPT
Maximum PV Array Power4000 W
MPPT Range @ Operating Voltage60 ~ 115 VDC
Maximum PV Array Open Circuit Voltage145 VDC
Maximum Solar Charge Current80 A
Maximum AC Charge Current60 A
Communication
Communication InterfaceRS232 & USB
Mechanical Data
Dimension, D x W x H(mm)465 x 190 x 336
Net Weight (kgs)16
Operating Environment
Humidity5% to 95% Relative Humidity(Non-condensing)
Operating Temperature-10°C to 50°C
Storage Temperature-15°C to 60°C

Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.

Availability & grid compliance in the UAE

MarketUAE
Grid authority / regulatorDEWA, ADDC, SEWA
Quotation currencyAED
Support hours timezoneAsia/Dubai
Main citiesDubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

For prices, see Voltronic Inverters: Prices in UAE. Store pickup — collect your order from our store in Dubai or Riyadh.

Key Features & Technical Highlights

  • True double-conversion online UPS
  • Output power factor 1.0
  • Built-in 80A MPPT solar charger: Built-in 80A MPPT solar charger and 60A AC charger
  • Configurable AC/Solar input priority via: Configurable AC/Solar input priority via LCD setting
  • Parallel operation up to 9: Parallel operation up to 9 units
  • Common 48Vdc battery pack for: Common 48Vdc battery pack for the parallel system
  • Configurable charging current via LCD: Configurable charging current via LCD setting
  • Compatible with Generator
  • Cold Start capability
  • Overload and short circuit protection

Frequently Asked Questions

What voltage does the Voltronic UPS Solar 5KW operate on?

The Voltronic UPS Solar 5KW has a nominal voltage of 48 VDC and an operating voltage range of 110-280 VAC.

What are the physical dimensions and weight of the Voltronic UPS Solar 5KW?

The Voltronic UPS Solar 5KW measures 465 x 190 x 336 and weighs 16.

What is the operating temperature range of the Voltronic UPS Solar 5KW?

The Voltronic UPS Solar 5KW operates across -10°C to 50°C and a humidity range of 5% to 95% Relative Humidity(Non-condensing).

What solar input can the Voltronic UPS Solar 5KW handle?

The Voltronic UPS Solar 5KW supports a maximum PV array power of 4000 W, a maximum solar charge current of 80 A and a maximum PV array open-circuit voltage of 145 VDC.

What output waveform does the Voltronic UPS Solar 5KW produce?

The Voltronic UPS Solar 5KW produces a Pure Sinewave output waveform.

How does the Voltronic UPS Solar 5KW regulate voltage?

The Voltronic UPS Solar 5KW provides a voltage regulation of 230 VAC ± 5%.

What communication options does the Voltronic UPS Solar 5KW offer?

The Voltronic UPS Solar 5KW offers RS232 & USB connectivity for monitoring and control.

What is the power quality of the Voltronic UPS Solar 5KW?

The Voltronic UPS Solar 5KW has a power factor of > 0.98 @ Nominal Voltage (100% Load) and a harmonic distortion of < 10%.

What warranty coverage is available for the Voltronic UPS Solar 5KW?

The Voltronic UPS Solar 5KW is backed by a 2-year manufacturer warranty from Voltronic Power.