Voltronic Power Hybrid Solar Inverters INFINISOLAR-WP-TWIN-HMI-12/15KW
Discover the InfiniSolar WP TWIN HMI 12kw by Voltronic Power with 16000 W max DC power and 1000 VDC max voltage for efficient energy conversion.
Models and prices
- VOLTRONIC-INFINISOLAR-WP-TWIN-HMI-12KWAED 14,000incl. VAT
- VOLTRONIC-INFINISOLAR-WP-TWIN-HMI-15KWAED 14,000incl. VAT
Technical Specifications
| Parameter | VOLTRONIC-INFINISOLAR-WP-TWIN-HMI-12KW | VOLTRONIC-INFINISOLAR-WP-TWIN-HMI-15KW |
|---|---|---|
| Additional Specifications | ||
| Maximum Discharge Cuurent Imax (8/20s) kA | 40 | |
| Nominal Discharge Current In (8/20s) KA | 20 | |
| Response Time (ns) | <25 | |
| Voltage protection Level Up (VDC) KV | ≤2.0 | |
| Protection | 0~1000 m** | |
| Efficiency | >96% | |
| Efficiency (DC to AC) | 91% | |
| European Efficiency@ Vnominal | >95% | |
| Net Weight (kgs) | 75 | 78 |
| PV Input | ||
| Maximum DC Power | 16000 W | 22500 W |
| Maximum DC Voltage | 1000 VDC | |
| MPP Voltage Range | 350 VDC ~ 950 VDC | |
| Number of MPP Trackers / Maximum Input Current | 2 / A: 26A, B: 26A | |
| AC Output | ||
| Nominal Output Voltage | 230 VAC (P-N) | 400 VAC (P-P) |
| Output Voltage Range | 184 - 265 VAC per phase | |
| Nominal Output Current | 17.4 A per phase | 21.7 A per phase |
| Power Factor range | 0.9 lag – 0.9 lead | |
| Efficiency | ||
| Maximum Conversion Efficiency (DC/AC) | >96% | |
| European Efficiency@ Nominal | >95% | |
| Battery Input | ||
| Battery Voltage Range | 40 ~60 VDC | |
| Maximum Charging Current | 250 A | 300 A |
| Communication | ||
| Communication Port | RS-232, RS-485, USB, CAN and Wi-Fi | |
| Intelligent Slot | Optional for SNMP and Modbus cards | |
| Certifications | ||
| Safety | IEC 62109, IEC 62116, IEC 61727, IEC 61683 | |
| Grid Connection Standard | NRS097-2-1:2017, VDE-AR-N4105, G99 | |
| Mechanical Data | ||
| Dimension, D x W x H (mm) | 255 x 660 x 750 | |
| Operating Conditions | ||
| Humidity | 0 ~ 100% RH (Non-condensing) | |
| Operating Temperature | -25 to 60°C; > 45°C power derating | |
| Altitude | 0 ~ 1000 m | |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- IP66 certified enclosure
- User-friendly HMI LCD design for: User-friendly HMI LCD design for easy configuration
- Built-in WiFi for mobile monitoring
- 150% unbalanced load support
- 26A maximum PV input current
- Dual outputs for smart load: Dual outputs for smart load management
- User-adjustable charging current
- Reserved communication port for BMS: Reserved communication port for BMS (RS485)
- Parallel operation up to 6: Parallel operation up to 6 units
Frequently Asked Questions
What voltage does the Voltronic Hybrid Solar Inverter InfiniSolar WP TWIN HMI 12kw operate on?
The Voltronic Hybrid Solar Inverter InfiniSolar WP TWIN HMI 12kw has a nominal voltage of 40 ~60 VDC and an operating voltage range of 350 VDC ~ 950 VDC.
What are the physical dimensions and weight of the Voltronic Hybrid Solar Inverter InfiniSolar WP TWIN HMI 12kw?
The Voltronic Hybrid Solar Inverter InfiniSolar WP TWIN HMI 12kw measures 255 x 660 x 750 and weighs 75.
What is the operating temperature range of the Voltronic Hybrid Solar Inverter InfiniSolar WP TWIN HMI 12kw?
The Voltronic Hybrid Solar Inverter InfiniSolar WP TWIN HMI 12kw operates across -25 to 60°C and a humidity range of 0 ~ 100% RH (Non-condensing).
What is the efficiency of the Voltronic Hybrid Solar Inverter InfiniSolar WP TWIN HMI 12kw?
The Voltronic Hybrid Solar Inverter InfiniSolar WP TWIN HMI 12kw has an efficiency of >96%.
What is the maximum charge current of the Voltronic Hybrid Solar Inverter InfiniSolar WP TWIN HMI 12kw?
The Voltronic Hybrid Solar Inverter InfiniSolar WP TWIN HMI 12kw has a maximum charge current of 250 A.
What communication options does the Voltronic Hybrid Solar Inverter InfiniSolar WP TWIN HMI 12kw offer?
The Voltronic Hybrid Solar Inverter InfiniSolar WP TWIN HMI 12kw offers RS-232, RS-485, USB, CAN and Wi-Fi connectivity for monitoring and control.
What is the power quality of the Voltronic Hybrid Solar Inverter InfiniSolar WP TWIN HMI 12kw?
The Voltronic Hybrid Solar Inverter InfiniSolar WP TWIN HMI 12kw has a power factor of 0.9 lag – 0.9 lead.
What certifications does the Voltronic Hybrid Solar Inverter InfiniSolar WP TWIN HMI 12kw have?
The Voltronic Hybrid Solar Inverter InfiniSolar WP TWIN HMI 12kw is certified to IEC 62109, IEC 62116, IEC 61727, IEC 61683, NRS097-2-1:2017, VDE-AR-N4105 and G99, meeting recognised international standards for safety and performance.
What warranty coverage is available for the Voltronic Hybrid Solar Inverter InfiniSolar WP TWIN HMI 12kw?
The Voltronic Hybrid Solar Inverter InfiniSolar WP TWIN HMI 12kw is backed by a 2-year manufacturer warranty from Voltronic Power.
What voltage does the Voltronic Hybrid Solar Inverter InfiniSolar WP TWIN HMI 15kw operate on?
The Voltronic Hybrid Solar Inverter InfiniSolar WP TWIN HMI 15kw has a nominal voltage of 40 ~60 VDC and an operating voltage range of 350 VDC ~ 950 VDC.