Models and prices
- VOLTRONIC-EVOLUTION-400AED 1,100incl. VAT
- VOLTRONIC-EVOLUTION-600AED 1,100incl. VAT
- VOLTRONIC-EVOLUTION-800AED 1,100incl. VAT
Technical Specifications
| Parameter | VOLTRONIC-EVOLUTION-400 | VOLTRONIC-EVOLUTION-600 | VOLTRONIC-EVOLUTION-800 |
|---|---|---|---|
| Electrical / AC Output Data | |||
| Rated Output Power (VA) | 400VA | 600VA | 800VA |
| Rated Output Power (W) | 240W | 360W | 480W |
| Input | |||
| Voltage | 110/120 VAC or 220/230/240 VAC | ||
| Voltage Range | 81-134VAC/89-145VAC or 162-268VAC/170-280VAC/177-290VAC | ||
| Frequency Range | 60/50 Hz (Auto sensing) | ||
| Output | |||
| AC Voltage Regulation (Batt. Mode) | ±10% | ||
| Frequency Range (Batt. Mode) | 60 Hz or 50 Hz ±1 Hz | ||
| Transfer Time | Typical 2-6 ms, 10 ms max. | ||
| Waveform (Batt. Mode) | Simulated Sinewave | ||
| Battery | |||
| Battery Type & Number | 12 V 4.5 Ah x 1 | 12 V/5 Ah x 1 | 12 V/5 Ah x 1 |
| Typical Recharge Time | 4-6 hours recover to 90% capacity | ||
| Physical | |||
| Dimension, D x W x H (mm) | 245 x 163 x 90 | ||
| Net Weight (kgs) | 3.5 | 4.0 | 4.5 |
| Protection Features | |||
| Full Protection | Overload, discharge, and overcharge protection | ||
| Operating Conditions | |||
| Humidity | 0 to 90% Relative Humidity (Non-condensing) | ||
| Noise Level | Less than 40dB | ||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- Compact size
- Boost and buck AVR for: Boost and buck AVR for voltage stabilization
- Auto restart while AC is: Auto restart while AC is recovering
- Simulated sine wave output
- Off-mode charging
- Cold start function
- Generator compatible (option)
- Optional 5V USB charging port
- Compact size for stand and: Compact size for stand and mounting flexibility
Frequently Asked Questions
What is the rated power of the Voltronic 0.4 kVA UPS Evolution 400?
The Voltronic 0.4 kVA UPS Evolution 400 has a rated power of 240W.
What voltage does the Voltronic 0.4 kVA UPS Evolution 400 operate on?
The Voltronic 0.4 kVA UPS Evolution 400 has a nominal voltage of 110/120 VAC or 220/230/240 VAC and an operating voltage range of 81-134 VAC/89-145 VAC or 162-268 VAC/170-280 VAC/177-290 VAC.
What are the physical dimensions and weight of the Voltronic 0.4 kVA UPS Evolution 400?
The Voltronic 0.4 kVA UPS Evolution 400 measures 245 x 163 x 90 and weighs 3.5.
What transfer time and output waveform does the Voltronic 0.4 kVA UPS Evolution 400 provide?
The Voltronic 0.4 kVA UPS Evolution 400 has a transfer time of Typical 2-6 ms, 10 ms max. and an output waveform of Simulated Sinewave.
How does the Voltronic 0.4 kVA UPS Evolution 400 regulate voltage?
The Voltronic 0.4 kVA UPS Evolution 400 provides a voltage regulation of ±10%.
How loud is the Voltronic 0.4 kVA UPS Evolution 400 during operation?
The Voltronic 0.4 kVA UPS Evolution 400 has a noise level of Less than 40dB during operation.
What warranty coverage is available for the Voltronic 0.4 kVA UPS Evolution 400?
The Voltronic 0.4 kVA UPS Evolution 400 is backed by a 2-year manufacturer warranty from Voltronic Power.
What is the rated power of the Voltronic 0.6 kVA UPS Evolution 600?
The Voltronic 0.6 kVA UPS Evolution 600 has a rated power of 360W.
What voltage does the Voltronic 0.6 kVA UPS Evolution 600 operate on?
The Voltronic 0.6 kVA UPS Evolution 600 has a nominal voltage of 110/120 VAC or 220/230/240 VAC and an operating voltage range of 81-134 VAC/89-145 VAC or 162-268 VAC/170-280 VAC/177-290 VAC.
What are the physical dimensions and weight of the Voltronic 0.6 kVA UPS Evolution 600?
The Voltronic 0.6 kVA UPS Evolution 600 measures 245 x 163 x 90 and weighs 4.0.