Voltronic Power Off-Grid Solar Inverters Axpert VM II 1200-12/2500-24/3000-24/5000-48/Plus 3000-24
Discover the Axpert VM II 1200-12 inverter by Voltronic Power with 230VAC regulation, 2400VA surge power, and 93% efficiency.
Technical Specifications
| Parameter | Axpert VM II 1200-12 | Axpert VM II 2500-24 | Axpert VM II 3000-24 | Axpert VM II 5000-48 | Axpert VM II Plus 3000-24 |
|---|---|---|---|---|---|
| AC Output | |||||
| AC Voltage Regulation (Batt. Mode) | 230VAC ± 5% | ||||
| Surge Power | 2400VA | 5000VA | 6000VA | 10000VA | 6000VA |
| Efficiency (Peak) | 93% | ||||
| Transfer Time | 10 ms (For Personal Computers); 20 ms (For Home Appliances) | ||||
| Waveform | Pure sine wave | ||||
| Battery Input | |||||
| Battery Voltage | 12 VDC | 24 VDC | 24 VDC | 48 VDC | 24 VDC |
| Floating Charge Voltage | 13.5 VDC | 27 VDC | 27 VDC | 54 VDC | 27 VDC |
| Overcharge Protection | 16 VDC | 32 VDC | 33 VDC | 63 VDC | 32 VDC |
| Solar Charger & AC Charger | |||||
| Maximum PV Array Open Circuit Voltage | 350 VDC | 450 VDC | 500 VDC | 500 VDC | 450 VDC |
| Maximum PV Array Power | 2000W | 3000W | 4000W | 5000W | 3000W |
| MPP Range @ Operating Voltage | 60-300 VDC | 60-400 VDC | 120-450 VDC | 120-450 VDC | 60-400 VDC |
| Maximum Solar Charge Current | 80 A | 80 A | 100 A | 100 A | 80 A |
| Maximum AC Charge Current | 80 A | 80 A | 100 A | 100 A | 80 A |
| Maximum Charge Current | 80 A | 80 A | 100 A | 100 A | 80 A |
| Additional Specifications | |||||
| No Load Power Consumption | <35W | ||||
| Rated Power | 1200VA/1200W | 2500VA/2500W | 3000VA/3000W | — | — |
| Maximum PV Input Current | 40A | ||||
| Low Loss Return Voltage | 180Vac± 7V (UPS); 100Vac± 7V (Appliances) | ||||
| High Loss Voltage | 280Vac± 7V | ||||
| High Loss Return Voltage | 270Vac± 7V | ||||
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) | ||||
| Low Loss Return Frequency | 42± 1Hz | ||||
| High Loss Frequency | 65± 1Hz | ||||
| High Loss Return Frequency | 63± 1Hz | ||||
| Output Short Circuit Protection | Circuit Breaker | ||||
| Surge Capacity | 2* rated power for 5 seconds | ||||
| Solar Charger type | MPPT | ||||
| Compliance Safety | IEC 62109, IEC 61683, EN/IEC 61000-6-2, 61000-6-4, 61000-3-11, 61000-3-12 | ||||
| High DC Cut-off Voltage | 16Vdc | ||||
| Floating Charging Voltage | 13.5Vdc | ||||
| Max AC Input Voltage | 300Vac | ||||
| Nominal DC Input Voltage | 12Vdc | ||||
| Mechanical Data | |||||
| Dimension, D x W x H (mm) | 90 x 288 x 357 | 100 x 288 x 390 | 100 x 300 x 440 | 100 x 300 x 440 | 100 x 300 x 440 |
| Net Weight (kgs) | 6.5 | 7.1 | 9 | 10 | 7.5 |
| Weight | 6.5 | 7.1 | 9 | 10 | 7.5 |
| Communication Interface | RS232 | RS232 | USB/RS232 (optional USB/Dry contact) | USB/RS232 (optional USB/Dry contact) | RS232 |
| Operating Conditions | |||||
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | ||||
| Operating Temperature | -10°C to 50°C | ||||
| Storage Temperature | -15°C to 60°C | ||||
| Electrical / AC Output Data | |||||
| Selectable Voltage Range | 170-280 | ||||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Delivery & installation coverage | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- Pure sine wave solar inverter
- Output power factor 1
- High PV input voltage range
- Battery independent design
- Battery equalization function to optimize: Battery equalization function to optimize battery performance and extend lifecycle
Frequently Asked Questions
The Voltronic 1.2 kW Off-Grid Solar Inverter Axpert VM II 1200-12 has a rated power of 1200 VA/1200W and a surge capability of 2400 VA.
The Voltronic 1.2 kW Off-Grid Solar Inverter Axpert VM II 1200-12 has a nominal voltage of 12 VDC.
The Voltronic 1.2 kW Off-Grid Solar Inverter Axpert VM II 1200-12 measures 90 x 288 x 357 and weighs 6.5.
The Voltronic 1.2 kW Off-Grid Solar Inverter Axpert VM II 1200-12 operates across -10°C to 50°C and a humidity range of 5% to 95% Relative Humidity (Non-condensing).
The Voltronic 1.2 kW Off-Grid Solar Inverter Axpert VM II 1200-12 has an efficiency of 93%.
The Voltronic 1.2 kW Off-Grid Solar Inverter Axpert VM II 1200-12 supports a maximum PV array power of 2000W, a maximum solar charge current of 80 A and a maximum PV array open-circuit voltage of 350 VDC.
The Voltronic 1.2 kW Off-Grid Solar Inverter Axpert VM II 1200-12 has a transfer time of 10 ms in UPS mode (For Personal Computers) and an output waveform of Pure sine wave.
The Voltronic 1.2 kW Off-Grid Solar Inverter Axpert VM II 1200-12 provides a voltage regulation of 230 VAC ± 5%.
The Voltronic 1.2 kW Off-Grid Solar Inverter Axpert VM II 1200-12 offers RS232 connectivity for monitoring and control.
The Voltronic 1.2 kW Off-Grid Solar Inverter Axpert VM II 1200-12 is backed by a 2-year manufacturer warranty from Voltronic Power.