Voltronic Power Off-Grid Solar Inverters VM-II-4000-TWIN-PV-5600 / VOLTRONIC-VM-II-6000-TWIN-PV-8000
Discover the VM II-4000 TWIN-PV 5600 inverter by Voltronic Power with 230 VAC, 8000VA surge power, and auto-sensing frequency for optimal performance.
Models and prices
- VOLTRONIC-VM-II-4000-TWIN-PV-5600AED 2,200incl. VAT
- VOLTRONIC-VM-II-6000-TWIN-PV-8000AED 2,200incl. VAT
Technical Specifications
| Parameter | VOLTRONIC-VM-II-4000-TWIN-PV-5600 | VOLTRONIC-VM-II-6000-TWIN-PV-8000 |
|---|---|---|
| Input | ||
| Voltage | 230 VAC | |
| Selectable Voltage Range | 170-280 VAC (For Personal Computers) | 90-280 VAC (For Home Appliances) |
| Frequency Range | 50 Hz/60 Hz (Auto sensing) | |
| Output | ||
| AC Voltage Regulation (Batt. Mode) | 230VAC ± 5% | |
| Efficiency (Peak) | 93% | |
| Transfer Time | 10 ms (For Personal Computers) | 20 ms (For Home Appliances) |
| Waveform | Pure sine wave | |
| Electrical Data | ||
| Surge Power | 8000VA | 12000VA |
| Battery Voltage | 24 VDC | 48 VDC |
| Floating Charge Voltage | 27 VDC | 54 VDC |
| Overcharge Protection | 33 VDC | 63 VDC |
| Maximum PV Array Power | 5600W | 8000W |
| Built-in Charger | ||
| Solar Charger type | MPPT | |
| Maximum PV Array Open Circuit Voltage | 500 VDC | |
| Maximum PV Input Current | 40A | |
| MPP Range @ Operating Voltage | 60-450 VDC | |
| Maximum Solar Charge Current | 120A | |
| Maximum AC Charge Current | 100A | |
| Maximum Charge Current | 120A | |
| Additional Specifications | ||
| Dual Outputs | Yes | |
| Mechanical Data | ||
| Dimension, D x W x H (mm) | 122 x 322.7 x 420.3 | |
| Net Weight (kgs) | 9.5 | 10.5 |
| Communication Interface | USB/RS232/RS485/Wi-Fi | |
| Operating Conditions | ||
| Humidity | 5% to 95% Relative Humidity(Non-condensing) | |
| Operating Temperature | -10°C to 50°C | |
| Storage Temperature | -15°C to 60°C | |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- Increased PV power to 5600W
- Maximum PV input current 40A
- Dual outputs, for smart load: Dual outputs, for smart load management
- Built-in WiFi for mobile monitoring: Built-in WiFi for mobile monitoring and OTA firmware upgrade
- Supports USB On-the-Go function
- Built-in BMS communication port
- Built-in meter calibration for optimized: Built-in meter calibration for optimized system operation
- Battery independent design
- Built-in anti-dust kit
- Increased PV power to 8000W
Frequently Asked Questions
What voltage does the Voltronic Off-Grid Solar Inverter VM II-4000 TWIN-PV 5600 operate on?
The Voltronic Off-Grid Solar Inverter VM II-4000 TWIN-PV 5600 has a nominal voltage of 24 VDC and an operating voltage range of 170-280 VAC in UPS mode (For Personal Computers).
What are the physical dimensions and weight of the Voltronic Off-Grid Solar Inverter VM II-4000 TWIN-PV 5600?
The Voltronic Off-Grid Solar Inverter VM II-4000 TWIN-PV 5600 measures 122 x 322.7 x 420.3 and weighs 9.5.
What is the operating temperature range of the Voltronic Off-Grid Solar Inverter VM II-4000 TWIN-PV 5600?
The Voltronic Off-Grid Solar Inverter VM II-4000 TWIN-PV 5600 operates across -10°C to 50°C and a humidity range of 5% to 95% Relative Humidity(Non-condensing).
What is the efficiency of the Voltronic Off-Grid Solar Inverter VM II-4000 TWIN-PV 5600?
The Voltronic Off-Grid Solar Inverter VM II-4000 TWIN-PV 5600 has an efficiency of 93%.
What solar input can the Voltronic Off-Grid Solar Inverter VM II-4000 TWIN-PV 5600 handle?
The Voltronic Off-Grid Solar Inverter VM II-4000 TWIN-PV 5600 supports a maximum PV array power of 5600W, a maximum solar charge current of 120A and a maximum PV array open-circuit voltage of 500 VDC.
What transfer time and output waveform does the Voltronic Off-Grid Solar Inverter VM II-4000 TWIN-PV 5600 provide?
The Voltronic Off-Grid Solar Inverter VM II-4000 TWIN-PV 5600 has a transfer time of 10 ms in UPS mode (For Personal Computers) and an output waveform of Pure sine wave.
How does the Voltronic Off-Grid Solar Inverter VM II-4000 TWIN-PV 5600 regulate voltage?
The Voltronic Off-Grid Solar Inverter VM II-4000 TWIN-PV 5600 provides a voltage regulation of 230 VAC ± 5%.
What communication options does the Voltronic Off-Grid Solar Inverter VM II-4000 TWIN-PV 5600 offer?
The Voltronic Off-Grid Solar Inverter VM II-4000 TWIN-PV 5600 offers USB/RS232/RS485/Wi-Fi connectivity for monitoring and control.
What warranty coverage is available for the Voltronic Off-Grid Solar Inverter VM II-4000 TWIN-PV 5600?
The Voltronic Off-Grid Solar Inverter VM II-4000 TWIN-PV 5600 is backed by a 2-year manufacturer warranty from Voltronic Power.
What voltage does the Voltronic Off-Grid Solar Inverter VM II-6000 TWIN-PV 8000 operate on?
The Voltronic Off-Grid Solar Inverter VM II-6000 TWIN-PV 8000 has a nominal voltage of 48 VDC and an operating voltage range of 90-280 VAC in UPS mode (For Home Appliances).