Voltronic Power Inverters AXPERT-MAX-E-DUPLEX-11K / AXPERT-MAX-E-DUPLEX-11K
An 11000W off-grid inverter whose two independent 27A PV inputs let one Duplex 11K carry a 5500W x 2 array across two roof faces, each string starting at 80V ±5Vdc.
Models and prices
- VOLTRONIC-AXPERT-MAX-E-DUPLEX-11KAED 4,638incl. VAT
- AXPERT-MAX-E-DUPLEX-11KAED 1,785incl. VAT
Technical Specifications
| Parameter | VOLTRONIC-AXPERT-MAX-E-DUPLEX-11K | AXPERT-MAX-E-DUPLEX-11K |
|---|---|---|
| Electrical Data | ||
| Circulation Current under No Load Condition | Max 2A | |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | |
| High Loss Return Frequency | 63±1Hz | |
| Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) | |
| Low Loss Voltage | 170Vac±7V (UPS) 90Vac±7V (Appliances) | |
| Max AC Input Current | 60A | |
| Max. Input Current | 27A x 2 (MAX 40A) | |
| Max. PV Array Open Circuit Voltage | 500Vdc | |
| Nominal Input Voltage | 230Vac | |
| PV Array MPPT Voltage Range | 90Vdc 450Vdc | |
| Transfer time in parallel mode | Max 50ms | |
| High DC Cut-off Voltage | 63Vdc | |
| Peak Efficiency | 93% | |
| Battery | 56.4Vdc | |
| Charging Current | 150A UPS | |
| Efficiency | >95% ( Rated R load Line Mode | |
| Floating Charging Voltage | 54Vdc | |
| Output Voltage Regulation | 230Vac± 5% | |
| Rated Output Power | 11000W | |
| Rated Power | 11000W Max. PV Array Open Circuit | |
| Safety Certification | CE | |
| Additional Specifications | ||
| High Loss Frequency | 65±1Hz | |
| High Loss Return Voltage | 270Vac±7V | |
| High Loss Voltage | 280Vac±7V | |
| Low Loss Frequency | 40±1Hz | |
| Low Loss Return Frequency | 42±1Hz | |
| Max AC Input Voltage | 300Vac | |
| Max. Charging Current | 150A | |
| Nominal Input Frequency | 50Hz/60Hz (Auto detection) | |
| Output Short Circuit Protection | Line mode: Circuit Breaker (70A) Battery mode: Electronic Circuits | |
| Parallel Kit | YES | |
| Parallel communication | CAN | |
| Power Unbalance Ratio | <5% 100% Load | |
| Max parallel numbers | 6 | |
| DC Offset | ≤100mV | |
| High DC Recovery Voltage | 61Vdc | |
| DC Voltage | DC Offset ≦100mV Power Limitation 55Vdc | |
| Input Voltage Waveform | Sinusoidal (utility or generator) Nominal | |
| Output Frequency | 60Hz or 50Hz Peak | |
| Overload Protection | Surge | |
| Start-up Voltage | 80V +/- 5Vdc Power Limitation PV Current MPPT temperature 75° 80° | |
| Selectable Voltage Range | 170-280 VAC (For Personal Computers) 90-280 VAC (For Home Appliances) | |
| Maxmum Solar Charge Current | 150A | |
| Battery | ||
| Overcharge Protection | 63Vdc Charging Algorithm 3-Step Charging Curve Time | 63 VDC |
| Battery Voltage | 48 VDC | |
| Floating Charge Voltage | 54 VDC | |
| AC Output | ||
| Transfer Time | 10ms typical (UPS); | 10 ms (For Personal Computers), 20 ms (For Home Appliances) |
| AC Voltage Regulation (Batt. Mode) | 230VAC ± 5% | |
| Surge Power | 22000VA | |
| Efficiency (Peak) | 93% | |
| Waveform | Pure sine wave | |
| Solar Charger & AC Charger | ||
| Maximum PV Array Power | 11000W (5500W x 2) | |
| MPPT Range @ Operating Voltage | 90 – 450 VDC | |
| Maximum PV Array Open Circuit Voltage | 500 VDC | |
| Maximum PV Input Current | 27A x 2(MAX 40A) | |
| Maximum Solar Charge Current | 150A | |
| Maximum AC Charge Current | 150A | |
| Maximum Charge Current | 150A | |
| Communication | ||
| Communication Interface | USB/RS232/RS485/WiFi/Dry-contact | |
| Standard | ||
| Compliance Safety | CE | |
| Physical | ||
| Dimension, D x W x H (mm) | 147.4 x 432.5 x 553.6 | |
| Net Weight (kgs) | 18.4 | |
| Operating Environment | ||
| Humidity | 5% to 95% | 5% to 95% Relative Humidity(Non-condensing) |
| Storage Temperature | -15°C~ 60°C | -15°C to 60°C |
| Operating Temperature | -10°C to 50°C | |
| Operating Conditions | ||
| Operating Temperature Range | -10°C to 50°C | |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- Two independent PV inputs at 27A each: Each of the two PV inputs accepts 27A, 40A maximum, so an 11000W array can be split 5500W x 2 instead of being forced onto one tracker.
- 11000W rated output with 22000VA surge: The Duplex 11K delivers 11000W continuously and absorbs a 22000VA surge, holding a sinusoidal waveform on utility or generator input.
- 150A charging into a 48 VDC bank: Charge current reaches 150A from solar and 150A from AC into a 48 VDC bank, on a 3-step charging curve with 54Vdc float and 63Vdc overcharge cutoff.
- Output imbalance under 5% at 100% load: Output imbalance stays below 5% at 100% load and DC offset at 100mV or less, with regulation of 230VAC ± 5% in battery mode.
- 90Vdc-450Vdc MPPT with a 500Vdc ceiling: The MPPT tracks from 90Vdc to 450Vdc, tolerates 500Vdc open circuit and each string begins working at 80V ±5Vdc.
- Six units in parallel, 18.4 kg each: Up to 6 units run in parallel over USB/RS232/RS485/WiFi/Dry-contact, each unit 18.4 kg and 432.5 x 553.6 x 147.4 mm, rated -10°C to 50°C.
Frequently Asked Questions
What is the rated power of the Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX E Duplex 11K?
The Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX E Duplex 11K has a rated power of 11000W and a surge capability of 22000 VA.
What voltage does the Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX E Duplex 11K operate on?
The Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX E Duplex 11K has a nominal voltage of 48 VDC and an operating voltage range of 90 VDC 450 VDC.
What are the physical dimensions and weight of the Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX E Duplex 11K?
The Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX E Duplex 11K measures 147.4 x 432.5 x 553.6 and weighs 18.4.
What is the operating temperature range of the Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX E Duplex 11K?
The Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX E Duplex 11K operates across -10°C to 50°C and a humidity range of 5% to 95%.
What is the efficiency of the Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX E Duplex 11K?
The Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX E Duplex 11K has an efficiency of >95% (Rated R load, battery full charged).
What solar input can the Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX E Duplex 11K handle?
The Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX E Duplex 11K supports a maximum PV array power of 11000W (5500W x 2), a maximum solar charge current of 150A and a maximum PV array open-circuit voltage of 500 VDC.
What transfer time and output waveform does the Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX E Duplex 11K provide?
The Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX E Duplex 11K has a transfer time of Max 50ms and an output waveform of Sinusoidal (utility or generator) Nominal.
How does the Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX E Duplex 11K regulate voltage?
The Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX E Duplex 11K provides a voltage regulation of 230 VAC± 5%.
What communication options does the Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX E Duplex 11K offer?
The Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX E Duplex 11K offers USB/RS232/RS485/WiFi/Dry-contact connectivity for monitoring and control.
Can multiple Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX E Duplex 11K units run in parallel?
Yes — the Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX E Duplex 11K supports parallel operation (YES).