Voltronic Power Three-Phase Online UPS ARENA-2U-3U
Discover the Voltronic Power Arena 2U/3U UPS with 3-phase voltage range 190-520 VAC and precise AC voltage regulation for reliable power.
Models and prices
- VOLTRONIC-ARENA-2U-3UAED 25,000incl. VAT
Technical Specifications
| Parameter | VOLTRONIC-ARENA-2U-3U |
|---|---|
| Input | |
| Nominal Voltage | 3 x 360VAC/380VAC/400VAC/415VAC (3Ph+N+PE) / 3 x 360VAC/380VAC/400VAC/415VAC (3Ph+N+PE) / 208VAC/220VAC/230VAC/240VAC (1Ph+N+PE) / 100/200, 110/220, 120/208, 120/240, 127/220 VAC (2Ph+N+PE) / 3 x 360VAC/380VAC/400VAC/415VAC (3Ph+N+PE) / 3 x 360VAC/380VAC/400VAC/415VAC (3Ph+N+PE) / 208VAC/220VAC/230VAC/240VAC (1Ph+N+PE) / 100/200, 110/220, 120/208, 120/240, 127/220 VAC (2Ph+N+PE) / 3 x 173VAC/190VAC/200VAC/208VAC/220VAC (3Ph+N+PE) |
| Frequency Range | 40 Hz ~ 70 Hz |
| Power Factor | >= 0.99 @ 100% load |
| THDi | < 4% @ full linear load |
| Electrical Data | |
| Voltage Range | 190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load / 190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load / 110-300 VAC @ 50% load, 176-276 VAC @ 100% load / 88-155 VAC (L-N), 152-269 VAC (L-L) / 190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load / 190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load / 110-300 VAC @ 50% load, 176-276 VAC @ 100% load / 88-155 VAC (L-N), 152-269 VAC (L-L) / 88-155 VAC (L-N), 152-269 VAC (L-L) |
| Output Voltage | 360VAC/380VAC/400VAC/415VAC (3Ph+N) / 208*220/230/240VAC(L+N) / 208*220/230/240VAC(L+N) / 100/200,110/220,120/208,120/240,127/220VAC(2Ph+N) / 360VAC/380VAC/400VAC/415VAC (3Ph+N) / 208*220/230/240VAC(L+N) / 208*220/230/240VAC(L+N) / 100/200,110/220,120/208,120/240,127/220VAC(2Ph+N) / 173VAC/190VAC/200VAC/208VAC/220VAC(3Ph+N) |
| AC Mode | 94% / 94% / 93.5% / 91% / 94% / 94% / 93.5% / 91% / 92% |
| Battery Mode At Full Load | 93% / 92.5% / 92% / 91% / 93% / 92.5% / 92% / 91% / 92% |
| Battery Mode Peak | 93.5% / 93% / 92.5% / 91.5% / 93.5% / 93% / 92.5% / 91.5% / 92% |
| Battery Numbers | 12 pcs x 2 / 12 pcs x 2 / 12 pcs x 2 / 6 pcs x 2 / 16~20 pcs (adjustable) x 2 / 16~20 pcs (adjustable) x 2 / 16~20 pcs (adjustable) x 2 / 8~10pcs (adjustable) x 2 / 8~10pcs (adjustable) x 2 |
| Charging Voltage | ± 164V / ± 164V / ± 164V / ± 82V / ± 218V / ± 218V / ± 218V / ± 109V / ± 109V |
| Output | |
| AC Voltage Regulation (Batt. Mode) | ± 1% |
| Frequency Range (Synchronized Range) | 46~54Hz or 56~64Hz |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
| Current Crest Ratio | 3:1 (max.) |
| Harmonic Distortion | ≤ 2% THD (Linear Load) ; ≤ 3% THD (Non-linear Load) |
| Transfer Time | 0 ms |
| Waveform (Batt. Mode) | Pure Sinewave |
| Efficiency | |
| ECO Mode | 97% / 97% / 97% / 97% / 97% / 97% / 97% / 97% / 97% |
| Battery Charger | |
| Battery Voltage | ± 12V / 9 Ah |
| Typical Recharging Time | 9 hours recover to 90% capacity |
| Charging Current | ± 4A |
| Indicators | |
| LCD/LED Display | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
| Management | |
| Smart RS-232/USB | Supports Windows® Family, Linux and MAC |
| Optional SNMP | Power management from SNMP manager and web browser |
| Mechanical Data | |
| Dimension, D x W x H(mm) | 678 x 418 x 88 [2U] / 678 x 418 x 88 [2U] / 678 x 418 x 88 [2U] / 678 x 418 x 88 [2U] / 678 x 418 x 129 [3U] / 678 x 418 x 129 [3U] / 678 x 418 x 129 [3U] / 678 x 418 x 129 [3U] / 678 x 418 x 129 [3U] |
| Net Weight (kgs) | 17 / 17 / 17 / 14 / 20.5 / 20.5 / 20.5 / 17.6 / 21 |
| Additional Specifications | |
| Weight | 17 / 17 / 17 / 14 / 20.5 / 20.5 / 20.5 / 17.6 / 21 |
| Operating Conditions | |
| Operating Humidity | 0-95 % RH @ 0- 40°C (non-condensing) |
| Noise Level | Less than 55dB @ 1 Meter / Less than 55dB @ 1 Meter / Less than 55dB @ 1 Meter / Less than 58dB @ 1 Meter / Less than 55dB @ 1 Meter / Less than 55dB @ 1 Meter / Less than 55dB @ 1 Meter / Less than 58dB @ 1 Meter / Less than 58dB @ 1 Meter |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- True double-conversion
- DSP technology guarantees high reliability
- Output power factor 1.0
- 50Hz/60Hz frequency converter mode
- ECO mode operation for energy: ECO mode operation for energy saving
- Emergency power off function (EPO)
- Generator compatible
- Customized system (only available for: Customized system (only available for Arena 3U)
- Parallel operation with common battery
- Adjustable battery design
Frequently Asked Questions
What voltage does the Voltronic UPS Arena 2U/3U operate on?
The Voltronic UPS Arena 2U/3U has a nominal voltage of 3 x 360 VAC/380 VAC/400 VAC/415 VAC (3Ph+N+PE) / 3 x 360 VAC/380 VAC/400 VAC/415 VAC (3Ph+N+PE) / 208 VAC/220 VAC/230 VAC/240 VAC (1Ph+N+PE) / 100/200, 110/220, 120/208, 120/240, 127/220 VAC (2Ph+N+PE) / 3 x 360 VAC/380 VAC/400 VAC/415 VAC (3Ph+N+PE) / 3 x 360 VAC/380 VAC/400 VAC/415 VAC (3Ph+N+PE) / 208 VAC/220 VAC/230 VAC/240 VAC (1Ph+N+PE) / 100/200, 110/220, 120/208, 120/240, 127/220 VAC (2Ph+N+PE) / 3 x 173 VAC/190 VAC/200 VAC/208 VAC/220 VAC (3Ph+N+PE) and an operating voltage range of 190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load / 190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load / 110-300 VAC @ 50% load, 176-276 VAC @ 100% load / 88-155 VAC (L-N), 152-269 VAC (L-L) / 190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load / 190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load / 110-300 VAC @ 50% load, 176-276 VAC @ 100% load / 88-155 VAC (L-N), 152-269 VAC (L-L) / 88-155 VAC (L-N), 152-269 VAC (L-L).
What are the physical dimensions and weight of the Voltronic UPS Arena 2U/3U?
The Voltronic UPS Arena 2U/3U measures 678 x 418 x 88 [2U] / 678 x 418 x 88 [2U] / 678 x 418 x 88 [2U] / 678 x 418 x 88 [2U] / 678 x 418 x 129 [3U] / 678 x 418 x 129 [3U] / 678 x 418 x 129 [3U] / 678 x 418 x 129 [3U] / 678 x 418 x 129 [3U] and weighs 17 / 17 / 17 / 14 / 20.5 / 20.5 / 20.5 / 17.6 / 21.
What is the maximum charge current of the Voltronic UPS Arena 2U/3U?
The Voltronic UPS Arena 2U/3U has a maximum charge current of ± 4A.
What output waveform does the Voltronic UPS Arena 2U/3U produce?
The Voltronic UPS Arena 2U/3U produces a Pure Sinewave output waveform.
How does the Voltronic UPS Arena 2U/3U regulate voltage?
The Voltronic UPS Arena 2U/3U provides a voltage regulation of ± 1%.
How loud is the Voltronic UPS Arena 2U/3U during operation?
The Voltronic UPS Arena 2U/3U has a noise level of Less than 55dB @ 1 Meter / Less than 55dB @ 1 Meter / Less than 55dB @ 1 Meter / Less than 58dB @ 1 Meter / Less than 55dB @ 1 Meter / Less than 55dB @ 1 Meter / Less than 55dB @ 1 Meter / Less than 58dB @ 1 Meter / Less than 58dB @ 1 Meter during operation.
What is the power quality of the Voltronic UPS Arena 2U/3U?
The Voltronic UPS Arena 2U/3U has a power factor of >= 0.99 @ 100% load and a harmonic distortion of < 4% @ full linear load.
What warranty coverage is available for the Voltronic UPS Arena 2U/3U?
The Voltronic UPS Arena 2U/3U is backed by a 2-year manufacturer warranty from Voltronic Power.