Voltronic Power INFINISOLARVII-1.5KW
The InfiniSolarVII 1.5KW is a solar inverter rated 1.5KW. Every figure on this page is read from the manufacturer's manual for the InfiniSolarVII series.
Technical Specifications
| Parameter | INFINISOLARVII-1.5KW |
|---|---|
| Additional Specifications | |
| Max. PV Power | 2000W |
| Max. PV Array Open Circuit Voltage | 400VDC |
| Power Factor Range | >0.99 |
| Efficiency (DC to AC) | 93% |
| Maximum Charging Current (from Grid) | 30A |
| Maximum Charging Current (from PV) | 40A |
| Maximum Charging Current | 40A |
| External Safety Box (Optional) | Yes |
| MPPT Range @ Operating Voltage | 120 VDC~380 VDC |
| Number of MPP Tracker | 1 |
| Parallel Function | No |
| Communication Port | USB or RS-232/Dry Contact |
| Electrical / AC Output Data | |
| AC Output Voltage | 220/230/240 VAC |
| Nominal Output Current | 6.5A |
| Max Conversion Efficiency (DC/AC) | 95% |
| Rating of AC Transfer Relay | 30A |
| Feed-in Grid Voltage Range | ~ 195.5~253 VAC @India regulation 184 264.5 VAC@Germany regulation 184~264.5VAC @South America regulation |
| Feed-in Grid Frequency Range | 49~51Hz @India regulation 47.5 51.5Hz @Germany regulation 57~62Hz @South America regulation |
| Input Voltage Range | 90 - 280 VAC or 170 - 280 VAC |
| AC Frequency Range | 50 Hz/60 Hz (Auto sensing) |
| Communication | |
| Communication Interface | Dry-Contact or USB |
| PV String Input Data | |
| Nominal DC Voltage | 48 VDC |
| Mechanical Data | |
| Dimensions (W×H×D) | 100 x 300 x 440 |
| Operating Conditions | |
| Relative Humidity | 0 ~ 90% RH (No condensing) |
| Operating Temperature | 0 to 50°C |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Yemen
| Market | Yemen |
| Grid authority / regulator | Public Electricity Corporation (PEC), Ministry of Electricity and Energy |
| Quotation currency | YER |
| Support hours timezone | Asia/Aden |
| Delivery & installation coverage | Sana'a, Aden, Taiz, Al Hudaydah, Mukalla |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Yemen that is Public Electricity Corporation (PEC), Ministry of Electricity and Energy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.