Voltronic Power LIO-II-4810-LITHIUM-BATTERY-PACK-LIOII-4810
The LIO II 4810 Lithium Battery Pack LIOII-4810 is a lithium battery rated LIOII-4810. Every figure on this page is read from the manufacturer's manual for the
Download PDF Datasheet WhatsApp UsTechnical Specifications
| Parameter | LIO-II-4810-LITHIUM-BATTERY-PACK-LIOII-4810 |
|---|---|
| Electrical / AC Output Data | |
| Nominal Voltage | 51.2 VDC |
| Full Charge Voltage | 56 V ± 0.1 V |
| Full Discharge Voltage | 42 V |
| Internal Resistance | <20ΜΩ mΩ |
| Max Charging Voltage | 56 V ± 0.1 V |
| Battery Data | |
| Nominal Capacity | 100 Ah |
| Usable Energy | 5120 Wh kWh |
| Max Charge Current | 100 A (Default 30A) |
| Max Discharge Current | 150 A |
| Peak Discharge Current | 192 A at 1min |
| Standard Charge/Discharge Current | 0.2C CC (Constant Current) charge to FC, CV (Constant Voltage) charge till charge current decline to <0.05C |
| Protection Features | |
| Certification / Compliance Safety | UN38.3, IEC 62619, EN 61000-6-3 EN 61000-6-1, UKCA |
| Protection Features | BMS |
| Mechanical Data | |
| Dimensions (W×H×D) | 185 x 540 x 420 mm |
| Net Weight | 48 kg |
| Operating Conditions | |
| Operating Temperature | Charge: 0°C~50°C Discharge: 0°C~50°C |
| Storage Temperature Range | -20ºC ~ 60 °C 20°C±5°C is the recommended storage temperature |
| Communication | |
| Communication Interface | RS485 (RJ45), extension port (RJ11) |
Note: Specifications are based on the official Voltronic Power LIO-II-4810-LITHIUM-BATTERY-PACK-LIOII-4810 datasheet. Values may be subject to change; always verify against the latest manufacturer documentation before system design and procurement.
Availability & grid compliance in UAE
| Market | UAE |
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Delivery & installation coverage | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in UAE that is DEWA, ADDC, SEWA. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Availability & grid compliance in Kuwait
| Market | Kuwait |
| Grid authority / regulator | MEW Kuwait |
| Quotation currency | KWD |
| Support hours timezone | Asia/Kuwait |
| Delivery & installation coverage | Kuwait City, Hawalli, Salmiya |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Kuwait that is MEW Kuwait. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.