Voltronic Galleon II

Introducing the Galleon II, Voltronic Power's advanced Online UPS designed to deliver exceptional power protection. With a wide range of nominal voltages and precise AC voltage regulation, it ensures reliable performance across various applications.

Models Covered: Galleon II 1K, Galleon II 1.5K, Galleon II 2K, Galleon II 3K, Galleon II RM 1K, Galleon II RM 1.5K, Galleon II RM 2K, Galleon II RM 3K

Manufacturer: Voltronic Power Technology Corp.

Application: The Galleon II is ideal for safeguarding sensitive electronics, data centers, and critical IT infrastructure, providing uninterrupted power and stability.

Single Phase Online UPS True double-conversion Output power factor 0.9
Download PDF Datasheet WhatsApp Us

Technical Specifications

Technical Specifications
Parameter Galleon II 1KGalleon II 1.5KGalleon II 2KGalleon II 3KGalleon II RM 1KGalleon II RM 1.5KGalleon II RM 2KGalleon II RM 3K
Input
Nominal Voltage 100/110/115/120/127 VAC or 200/208/220/230/240 VAC100/110/115/120/127 VAC or 200/208/220/230/240 VAC100/110/115/120/127 VAC or 200/208/220/230/240 VAC100/110/115/120/127 VAC or 200/208/220/230/240 VAC100/110/115/120/127 VAC or 200/208/220/230/240 VAC100/110/115/120/127 VAC or 200/208/220/230/240 VAC100/110/115/120/127 VAC or 200/208/220/230/240 VAC100/110/115/120/127 VAC or 200/208/220/230/240 VAC
Voltage Range 55 - 150 VAC ± 5% or 110 - 300 VAC ± 5% @ 50% load55 - 150 VAC ± 5% or 110 - 300 VAC ± 5% @ 50% load55 - 150 VAC ± 5% or 110 - 300 VAC ± 5% @ 50% load55 - 150 VAC ± 5% or 110 - 300 VAC ± 5% @ 50% load55 - 150 VAC ± 5% or 110 - 300 VAC ± 5% @ 50% load55 - 150 VAC ± 5% or 110 - 300 VAC ± 5% @ 50% load55 - 150 VAC ± 5% or 110 - 300 VAC ± 5% @ 50% load55 - 150 VAC ± 5% or 110 - 300 VAC ± 5% @ 50% load
Frequency Range 40 Hz ~ 70 Hz40 Hz ~ 70 Hz40 Hz ~ 70 Hz40 Hz ~ 70 Hz40 Hz ~ 70 Hz40 Hz ~ 70 Hz40 Hz ~ 70 Hz40 Hz ~ 70 Hz
Power Factor ≥ 0.99 @ Nominal Voltage (100% Load)≥ 0.99 @ Nominal Voltage (100% Load)≥ 0.99 @ Nominal Voltage (100% Load)≥ 0.99 @ Nominal Voltage (100% Load)≥ 0.99 @ Nominal Voltage (100% Load)≥ 0.99 @ Nominal Voltage (100% Load)≥ 0.99 @ Nominal Voltage (100% Load)≥ 0.99 @ Nominal Voltage (100% Load)
Output
Output Voltage 100/110/115/120/127 VAC or 200/208/220/230/240 VAC100/110/115/120/127 VAC or 200/208/220/230/240 VAC100/110/115/120/127 VAC or 200/208/220/230/240 VAC100/110/115/120/127 VAC or 200/208/220/230/240 VAC100/110/115/120/127 VAC or 200/208/220/230/240 VAC100/110/115/120/127 VAC or 200/208/220/230/240 VAC100/110/115/120/127 VAC or 200/208/220/230/240 VAC100/110/115/120/127 VAC or 200/208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode) ± 1%± 1%± 1%± 1%± 1%± 1%± 1%± 1%
Frequency Range (Synchronized Range) 47 ~ 53 Hz or 57 ~ 63 Hz47 ~ 53 Hz or 57 ~ 63 Hz47 ~ 53 Hz or 57 ~ 63 Hz47 ~ 53 Hz or 57 ~ 63 Hz57 ~ 63 Hz or 47 ~ 53 Hz57 ~ 63 Hz or 47 ~ 53 Hz57 ~ 63 Hz or 47 ~ 53 Hz57 ~ 63 Hz or 47 ~ 53 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz60Hz ± 0.1Hz or 50 Hz ± 0.1Hz60Hz ± 0.1Hz or 50 Hz ± 0.1Hz60Hz ± 0.1Hz or 50 Hz ± 0.1Hz60Hz ± 0.1Hz or 50 Hz ± 0.1Hz
Current Crest Ratio 3:13:13:13:13:1 (max.)3:1 (max.)3:1 (max.)3:1 (max.)
Harmonic Distortion ≤ 2 % THD (Linear Load) ; ≤ 4 % THD (Non-linear Load)≤ 2 % THD (Linear Load) ; ≤ 4 % THD (Non-linear Load)≤ 2 % THD (Linear Load) ; ≤ 4 % THD (Non-linear Load)≤ 2 % THD (Linear Load) ; ≤ 4 % THD (Non-linear Load)≤ 2 % THD (Linear Load) ; ≤ 4 % THD (Non-linear Load)≤ 2 % THD (Linear Load) ; ≤ 4 % THD (Non-linear Load)≤ 2 % THD (Linear Load) ; ≤ 4 % THD (Non-linear Load)≤ 2 % THD (Linear Load) ; ≤ 4 % THD (Non-linear Load)
Transfer Time Zero
Waveform (Batt. Mode) Pure Sinewave
Efficiency
AC Mode 90%90%91%91%90%90%91%91%
ECO Mode 97%
Battery
Battery Type 12 V / 7 Ah12 V / 9 Ah12 V / 7 Ah12 V / 7 Ah12 V / 7 Ah12 V / 9 Ah12 V / 7 Ah12 V / 7 Ah
Numbers 33682366
Typical Recharge Time 4 hours recover to 90% capacity
Charging Current (max.) 1.5A1.5A1.2A1.2A1.5A*1.5A*1.5A*1.5A*
Charging Voltage 41.0 VDC ± 1%41.0 VDC ± 1%82.1 VDC ± 1%109.6 VDC ± 1%27.4 VDC ± 1%, 41.1 VDC ± 1%41.1 VDC ± 1%54.8 VDC ± 1%, 82.1 VDC ± 1%82.1 VDC ± 1%
Mechanical Data
Dimension, D×W×H (mm) 397 × 145 × 220397 × 145 × 220421 × 190 × 318421 × 190 × 318410 × 438 × 88410 × 438 × 88510 × 438 × 88630 × 438 × 88
Net Weight (kgs) 12.813.826.632.211.614.226.927.4
Operating Conditions
Humidity 20-95 % RH @ 0- 40°C (Non-condensing)20-95 % RH @ 0- 40°C (Non-condensing)20-95 % RH @ 0- 40°C (Non-condensing)20-95 % RH @ 0- 40°C (Non-condensing)20-90 % RH @ 0- 40°C (Non-condensing)20-90 % RH @ 0- 40°C (Non-condensing)20-90 % RH @ 0- 40°C (Non-condensing)20-90 % RH @ 0- 40°C (Non-condensing)
Noise Level Less than 50dB @1Meter
Communication
Smart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC

Note: Specifications are based on the official Voltronic Power datasheet. Values may be subject to change; always verify against the latest manufacturer documentation.

Key Features

True double-conversion

Input power factor correction 0.99

Output power factor 0.9

50Hz/60Hz frequency converter mode

Programmable power management outlets

Emergency power off function (EPO)

ECO mode operation for energy saving

Very high surge immunity up to 7KV, 13KA, 1300J

Applications & Use Cases

Typical Applications

  • Data centers
  • Hospitals and medical facilities
  • Banks and financial institutions
  • Telecommunications
  • Factories and industrial facilities

Regional Installation Notes (United Arab Emirates)

Climate Suitability: Suitable for United Arab Emirates's hot climate with reliable performance at high temperatures.

  • Ensure adequate ventilation
  • Protection from direct sunlight
  • Regular maintenance recommended

Frequently Asked Questions

What are the main performance specifications of the Galleon II?

The Galleon II offers high efficiency with 90% in AC mode and 97% in ECO mode. It supports a nominal voltage range of 100/110/115/120/127 VAC or 200/208/220/230/240 VAC, and a power factor of ≥ 0.99 at nominal voltage with 100% load.

Is the Galleon II compatible with different battery types?

Yes, the Galleon II uses a 12 V / 7 Ah battery type, making it compatible with standard UPS battery configurations.

What are the physical specifications of the Galleon II?

The Galleon II's physical dimensions and weight are designed for easy installation, but specific details such as IP rating are not provided in the key specifications.

What are the installation requirements for the Galleon II?

Installation requires a stable environment with a voltage range of 55 - 150 VAC or 110 - 300 VAC at 50% load. Ensure proper ventilation and adherence to safety standards.

What warranty is provided with the Galleon II?

The Galleon II comes with a standard warranty, details of which can be obtained from the retailer or Voltronic Power's customer service.

What certifications and standards does the Galleon II meet?

The Galleon II complies with standard certifications, ensuring reliability and safety in various operational environments.

What are the operating conditions for the Galleon II?

The Galleon II operates efficiently within a frequency range of 40 Hz to 70 Hz and maintains performance in various temperature and humidity conditions.

What are the key features and benefits of the Galleon II?

Key features include zero transfer time, pure sinewave output in battery mode, and low harmonic distortion, making it ideal for sensitive electronic equipment.