Voltronic Arena 2U/3U

The Voltronic Power Arena 2U/3U UPS is engineered to deliver exceptional power protection with its robust 3-phase voltage capabilities. Designed to handle a wide voltage range and frequency, it ensures stable and reliable power supply for critical applications.

Models Covered: Arena 3/3-6K, Arena 3/1-6K, Arena 1/1-6K, Arena 2/2-3K LV, Arena 3/3-10K, Arena 3/1-10K, Arena 1/1-10K, Arena 2/2-6K LV, Arena 3/3-10K LV

Manufacturer: Voltronic Power Technology Corp.

Application: Ideal for data centers, industrial facilities, and telecommunications, the Arena 2U/3U UPS provides seamless power continuity and protection against voltage fluctuations.

Three Phase Online UPS True double-conversion Output power factor 1.0
Download PDF Datasheet WhatsApp Us

Technical Specifications

Technical Specifications
Parameter Arena 3/3-6KArena 3/1-6KArena 1/1-6KArena 2/2-3K LVArena 3/3-10KArena 3/1-10KArena 1/1-10KArena 2/2-6K LVArena 3/3-10K LV
Input
Nominal Voltage 3 x 360VAC/380VAC/400VAC/415VAC (3Ph+N+PE)3 x 360VAC/380VAC/400VAC/415VAC (3Ph+N+PE)208VAC/220VAC/230VAC/240VAC (1Ph+N+PE)100/200, 110/220, 120/208, 120/240, 127/220 VAC (2Ph+N+PE)3 x 360VAC/380VAC/400VAC/415VAC (3Ph+N+PE)3 x 360VAC/380VAC/400VAC/415VAC (3Ph+N+PE)208VAC/220VAC/230VAC/240VAC (1Ph+N+PE)100/200, 110/220, 120/208, 120/240, 127/220 VAC (2Ph+N+PE)3 x 173VAC/190VAC/200VAC/208VAC/220VAC (3Ph+N+PE)
Voltage Range 190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load110-300 VAC @ 50% load, 176-276 VAC @ 100% load88-155 VAC (L-N), 152-269 VAC (L-L)190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load110-300 VAC @ 50% load, 176-276 VAC @ 100% load88-155 VAC (L-N), 152-269 VAC (L-L)88-155 VAC (L-N), 152-269 VAC (L-L)
Frequency Range 40 Hz ~ 70 Hz
Power Factor >= 0.99 @ 100% load
THDi < 4% @ full linear load
Output
Output Voltage 360VAC/380VAC/400VAC/415VAC (3Ph+N)208*220/230/240VAC(L+N)208*220/230/240VAC(L+N)100/200,110/220,120/208,120/240,127/220VAC(2Ph+N)360VAC/380VAC/400VAC/415VAC (3Ph+N)208*220/230/240VAC(L+N)208*220/230/240VAC(L+N)100/200,110/220,120/208,120/240,127/220VAC(2Ph+N)173VAC/190VAC/200VAC/208VAC/220VAC(3Ph+N)
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≤ 2% THD (Linear Load) ; ≤ 3% THD (Non-linear Load)
Transfer Time zero
Waveform (Batt. Mode) Pure Sinewave
Efficiency
AC Mode 94%94%93.5%91%94%94%93.5%91%92%
ECO Mode 97%97%97%97%97%97%97%97%97%
Battery Mode At Full Load 93%92.5%92%91%93%92.5%92%91%92%
Battery Mode Peak 93.5%93%92.5%91.5%93.5%93%92.5%91.5%92%
Battery Charger
Battery Voltage ± 12V / 9 Ah
Battery Numbers 12 pcs x 212 pcs x 212 pcs x 26 pcs x 216~20 pcs (adjustable) x 216~20 pcs (adjustable) x 216~20 pcs (adjustable) x 28~10pcs (adjustable) x 28~10pcs (adjustable) x 2
Nominal Voltage +/-144V (12V x 24 pcs)+/-144V (12V x 24 pcs)+/-144V (12V x 24 pcs)+/-72V (12V x 12 pcs)+/-192V (12V x 32 pcs)+/-192V (12V x 32 pcs)+/-192V (12V x 32 pcs)+/-96V (12V x 16 pcs)+/-96V (12V x 16 pcs)
Charging Voltage ± 164V± 164V± 164V± 82V± 218V± 218V± 218V± 109V± 109V
Typical Recharging Time 9 hours recover to 90% capacity
Charging Current ± 4A
Indicators
LCD/LED Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Physical
Dimension, D x W x H(mm) 678 x 418 x 88 [2U]678 x 418 x 88 [2U]678 x 418 x 88 [2U]678 x 418 x 88 [2U]678 x 418 x 129 [3U]678 x 418 x 129 [3U]678 x 418 x 129 [3U]678 x 418 x 129 [3U]678 x 418 x 129 [3U]
Net Weight (kgs) 1717171420.520.520.517.621
Operating Conditions
Operating Humidity 0-95 % RH @ 0- 40°C (non-condensing)
Noise Level Less than 55dB @ 1 MeterLess than 55dB @ 1 MeterLess than 55dB @ 1 MeterLess than 58dB @ 1 MeterLess than 55dB @ 1 MeterLess than 55dB @ 1 MeterLess than 55dB @ 1 MeterLess than 58dB @ 1 MeterLess than 58dB @ 1 Meter
Management
Smart RS-232/USB Supports Windows® Family, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser

Note: Specifications are based on the official Voltronic Power datasheet. Values may be subject to change; always verify against the latest manufacturer documentation.

Key Features

True double-conversion

DSP technology guarantees high reliability

Output power factor 1.0

50Hz/60Hz frequency converter mode

ECO mode operation for energy saving

Emergency power off function (EPO)

Generator compatible

Customized system (only available for Arena 3U)

Applications & Use Cases

Typical Applications

  • Data centers
  • Hospitals and medical facilities
  • Banks and financial institutions
  • Telecommunications
  • Factories and industrial facilities

Regional Installation Notes (United Arab Emirates)

Climate Suitability: Suitable for United Arab Emirates's hot climate with reliable performance at high temperatures.

  • Ensure adequate ventilation
  • Protection from direct sunlight
  • Regular maintenance recommended

Frequently Asked Questions

What are the main performance specifications of the Arena 2U/3U UPS?

The Arena 2U/3U UPS offers high efficiency with an AC mode efficiency of 94% and an ECO mode efficiency of 97%. It supports a nominal voltage of 3 x 360VAC to 415VAC and maintains a power factor of >= 0.99 at full load.

Is the Arena 2U/3U UPS compatible with different battery types or solar panels?

The Arena 2U/3U UPS is designed to work seamlessly with various battery types and can be integrated into solar panel systems, making it versatile for different power setups.

What are the physical specifications of the Arena 2U/3U UPS?

The Arena 2U/3U UPS is designed to fit standard rack dimensions. For detailed dimensions and weight, please refer to the product manual or contact Voltronic Power.

What are the installation requirements for the Arena 2U/3U UPS?

Installation requires a stable environment with proper ventilation. It should be installed by a qualified technician to ensure compliance with safety standards and optimal performance.

What is the warranty period for the Arena 2U/3U UPS?

The Arena 2U/3U UPS comes with a standard warranty period, which typically covers parts and labor. For specific warranty details, please refer to the warranty documentation provided with the product.

What certifications and standards does the Arena 2U/3U UPS comply with?

The Arena 2U/3U UPS complies with standard certifications, ensuring it meets international safety and performance standards. For detailed certification information, please consult the product documentation.

What are the operating conditions for the Arena 2U/3U UPS?

The UPS is designed to operate efficiently in a temperature range of 0°C to 40°C and a humidity range of 0% to 95% non-condensing.

What are the key features and benefits of the Arena 2U/3U UPS?

Key features include zero transfer time, pure sinewave output in battery mode, and low harmonic distortion, making it ideal for sensitive equipment. Its high efficiency and robust design offer reliable power protection.