Voltronic Arena 2U/3U
تم تصميم UPS Arena 2U/3U من Voltronic Power لتوفير حماية طاقة استثنائية بفضل قدراته القوية في الجهد ثلاثي الأطوار. مصمم للتعامل مع مدى واسع من الجهد والتردد، يضمن إمداد طاقة ثابت وموثوق للتطبيقات الحيوية.
المواصفات الفنية
| المعامل | Arena 3/3-6K | Arena 3/1-6K | Arena 1/1-6K | Arena 2/2-3K LV | Arena 3/3-10K | Arena 3/1-10K | Arena 1/1-10K | Arena 2/2-6K LV | Arena 3/3-10K LV |
|---|---|---|---|---|---|---|---|---|---|
| الدخل | |||||||||
| Nominal Voltage | 3 x 360VAC/380VAC/400VAC/415VAC (3Ph+N+PE) | 3 x 360VAC/380VAC/400VAC/415VAC (3Ph+N+PE) | 208VAC/220VAC/230VAC/240VAC (1Ph+N+PE) | 100/200, 110/220, 120/208, 120/240, 127/220 VAC (2Ph+N+PE) | 3 x 360VAC/380VAC/400VAC/415VAC (3Ph+N+PE) | 3 x 360VAC/380VAC/400VAC/415VAC (3Ph+N+PE) | 208VAC/220VAC/230VAC/240VAC (1Ph+N+PE) | 100/200, 110/220, 120/208, 120/240, 127/220 VAC (2Ph+N+PE) | 3 x 173VAC/190VAC/200VAC/208VAC/220VAC (3Ph+N+PE) |
| Voltage Range | 190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load | 190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load | 110-300 VAC @ 50% load, 176-276 VAC @ 100% load | 88-155 VAC (L-N), 152-269 VAC (L-L) | 190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load | 190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load | 110-300 VAC @ 50% load, 176-276 VAC @ 100% load | 88-155 VAC (L-N), 152-269 VAC (L-L) | 88-155 VAC (L-N), 152-269 VAC (L-L) |
| Frequency Range | 40 Hz ~ 70 Hz | ||||||||
| Power Factor | >= 0.99 @ 100% load | ||||||||
| THDi | < 4% @ full linear load | ||||||||
| الخرج | |||||||||
| جهد الخرج | 360VAC/380VAC/400VAC/415VAC (3Ph+N) | 208*220/230/240VAC(L+N) | 208*220/230/240VAC(L+N) | 100/200,110/220,120/208,120/240,127/220VAC(2Ph+N) | 360VAC/380VAC/400VAC/415VAC (3Ph+N) | 208*220/230/240VAC(L+N) | 208*220/230/240VAC(L+N) | 100/200,110/220,120/208,120/240,127/220VAC(2Ph+N) | 173VAC/190VAC/200VAC/208VAC/220VAC(3Ph+N) |
| تنظيم جهد AC (وضع البطارية) | ± 1% | ||||||||
| Frequency Range (Synchronized Range) | 46~54Hz or 56~64Hz | ||||||||
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | ||||||||
| Current Crest Ratio | 3:1 (max.) | ||||||||
| Harmonic Distortion | ≤ 2% THD (Linear Load) ; ≤ 3% THD (Non-linear Load) | ||||||||
| زمن التحويل | zero | ||||||||
| Waveform (Batt. Mode) | Pure Sinewave | ||||||||
| الكفاءة | |||||||||
| AC Mode | 94% | 94% | 93.5% | 91% | 94% | 94% | 93.5% | 91% | 92% |
| ECO Mode | 97% | 97% | 97% | 97% | 97% | 97% | 97% | 97% | 97% |
| Battery Mode At Full Load | 93% | 92.5% | 92% | 91% | 93% | 92.5% | 92% | 91% | 92% |
| Battery Mode Peak | 93.5% | 93% | 92.5% | 91.5% | 93.5% | 93% | 92.5% | 91.5% | 92% |
| شاحن البطارية | |||||||||
| جهد البطارية | ± 12V / 9 Ah | ||||||||
| Battery Numbers | 12 pcs x 2 | 12 pcs x 2 | 12 pcs x 2 | 6 pcs x 2 | 16~20 pcs (adjustable) x 2 | 16~20 pcs (adjustable) x 2 | 16~20 pcs (adjustable) x 2 | 8~10pcs (adjustable) x 2 | 8~10pcs (adjustable) x 2 |
| Nominal Voltage | +/-144V (12V x 24 pcs) | +/-144V (12V x 24 pcs) | +/-144V (12V x 24 pcs) | +/-72V (12V x 12 pcs) | +/-192V (12V x 32 pcs) | +/-192V (12V x 32 pcs) | +/-192V (12V x 32 pcs) | +/-96V (12V x 16 pcs) | +/-96V (12V x 16 pcs) |
| Charging Voltage | ± 164V | ± 164V | ± 164V | ± 82V | ± 218V | ± 218V | ± 218V | ± 109V | ± 109V |
| Typical Recharging Time | 9 hours recover to 90% capacity | ||||||||
| Charging Current | ± 4A | ||||||||
| المؤشرات | |||||||||
| LCD/LED Display | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | ||||||||
| البيانات الميكانيكية | |||||||||
| Dimension, D x W x H(mm) | 678 x 418 x 88 [2U] | 678 x 418 x 88 [2U] | 678 x 418 x 88 [2U] | 678 x 418 x 88 [2U] | 678 x 418 x 129 [3U] | 678 x 418 x 129 [3U] | 678 x 418 x 129 [3U] | 678 x 418 x 129 [3U] | 678 x 418 x 129 [3U] |
| Net Weight (kgs) | 17 | 17 | 17 | 14 | 20.5 | 20.5 | 20.5 | 17.6 | 21 |
| ظروف التشغيل | |||||||||
| Operating Humidity | 0-95 % RH @ 0- 40°C (non-condensing) | ||||||||
| مستوى الضوضاء | Less than 55dB @ 1 Meter | Less than 55dB @ 1 Meter | Less than 55dB @ 1 Meter | Less than 58dB @ 1 Meter | Less than 55dB @ 1 Meter | Less than 55dB @ 1 Meter | Less than 55dB @ 1 Meter | Less than 58dB @ 1 Meter | Less than 58dB @ 1 Meter |
| الإدارة | |||||||||
| Smart RS-232/USB | Supports Windows® Family, Linux and MAC | ||||||||
| Optional SNMP | Power management from SNMP manager and web browser | ||||||||
ملاحظة: المواصفات مبنية على ورقة البيانات الرسمية من Voltronic Power. قد تخضع القيم للتغيير؛ تحقق دائمًا من أحدث وثائق الشركة المصنعة.
الميزات الرئيسية
True double-conversion
DSP technology guarantees high reliability
معامل قدرة الخرج 1.0
50Hz/60Hz frequency converter mode
ECO mode operation for energy saving
Emergency power off function (EPO)
متوافق مع المولد
Customized system (only available for Arena 3U)
التطبيقات وحالات الاستخدام
التطبيقات النموذجية
- مراكز البيانات
- المستشفيات والمرافق الطبية
- البنوك والمؤسسات المالية
- الاتصالات
- المصانع والمنشآت الصناعية
ملاحظات التركيب الإقليمية (الإمارات العربية المتحدة)
ملاءمة المناخ: مناسب لمناخ الإمارات العربية المتحدة الحار مع أداء موثوق في درجات الحرارة العالية.
- تأكد من التهوية المناسبة
- حماية من أشعة الشمس المباشرة
- صيانة دورية موصى بها
الأسئلة الشائعة
ما هي المواصفات الرئيسية لأداء UPS Arena 2U/3U؟
يوفر UPS Arena 2U/3U كفاءة عالية مع كفاءة وضع AC بنسبة 94% وكفاءة وضع ECO بنسبة 97%. يدعم جهدًا اسميًا من 3 x 360VAC إلى 415VAC ويحافظ على معامل قدرة >= 0.99 عند التحميل الكامل.
هل UPS Arena 2U/3U متوافق مع أنواع البطاريات المختلفة أو الألواح الشمسية؟
تم تصميم UPS Arena 2U/3U للعمل بسلاسة مع أنواع البطاريات المختلفة ويمكن دمجه في أنظمة الألواح الشمسية، مما يجعله متعدد الاستخدامات لمختلف إعدادات الطاقة.
ما هي المواصفات الفيزيائية لـ UPS Arena 2U/3U؟
تم تصميم UPS Arena 2U/3U ليتناسب مع أبعاد الرف القياسية. للحصول على الأبعاد والوزن بالتفصيل، يرجى الرجوع إلى دليل المنتج أو الاتصال بـ Voltronic Power.
ما هي متطلبات تركيب UPS Arena 2U/3U؟
يتطلب التركيب بيئة مستقرة مع تهوية مناسبة. يجب أن يتم التركيب بواسطة فني مؤهل لضمان الامتثال لمعايير السلامة والأداء الأمثل.
ما هي فترة الضمان لـ UPS Arena 2U/3U؟
يأتي UPS Arena 2U/3U بفترة ضمان قياسية تغطي عادةً الأجزاء والعمل. للحصول على تفاصيل الضمان المحددة، يرجى الرجوع إلى وثائق الضمان المرفقة مع المنتج.
ما هي الشهادات والمعايير التي يتوافق معها UPS Arena 2U/3U؟
يتوافق UPS Arena 2U/3U مع الشهادات القياسية، مما يضمن أنه يفي بمعايير السلامة والأداء الدولية. للحصول على معلومات الشهادات بالتفصيل، يرجى استشارة وثائق المنتج.
ما هي ظروف التشغيل لـ UPS Arena 2U/3U؟
تم تصميم UPS للعمل بكفاءة في نطاق درجة حرارة من 0°C إلى 40°C ونطاق رطوبة من 0% إلى 95% بدون تكثيف.
ما هي الميزات والفوائد الرئيسية لـ UPS Arena 2U/3U؟
تشمل الميزات الرئيسية وقت تحويل صفري، وموجة جيبية نقية في وضع البطارية، وتشويه منخفض في التوافقيات، مما يجعله مثاليًا للمعدات الحساسة. توفر كفاءته العالية وتصميمه القوي حماية موثوقة للطاقة.