Voltronic Power Solutions

Voltronic GALLEON-II-III

Discover Voltronic Power's Galleon II & III UPS systems with 3P/3P 10-40KVA, offering precise voltage regulation and wide frequency range.

Models Covered: VOLTRONIC-GALLEON-II-III

Manufacturer: Voltronic Power Technology Corp.

Application: Voltronic Power's Galleon II and III UPS systems are engineered for superior performance with 3P/3P configurations ranging from 10KVA to 40KVA. These systems ensure reliable power with precise voltage regulation and adaptable frequency ranges, making them ideal for critical applications. The Galleon series is perfect for data centers, industrial operations, and sensitive electronic environments where consistent power supply is crucial.

Technical Specifications

Technical Specifications
Parameter VOLTRONIC-GALLEON-II-III
Input
Nominal Voltage 3 x 400 VAC (3Ph+N) / 230 VAC (1Ph+N) / 3 x 360/380/400/415 VAC (3Ph+N) / 3 x 360/380/400/415 VAC (3Ph+N) / 3 x 360/380/400/415 VAC (3Ph+N)
Voltage Range 110-300 VAC ± 3 % @ 50% load; 176-276 VAC ± 3 % @ 100% load / 305VAC~457VAC / 305VAC~457VAC / 305VAC~457VAC
Frequency Range 46-54 Hz or 56-64Hz / 40-70 Hz / 40-70 Hz / 40-70 Hz
Power Factor > 0.99 @ 100% Load / N/A / N/A / N/A
Harmonic Distortion (THDi) < 4% at full linear load / N/A / N/A / N/A
Output
AC Voltage Regulation (Batt. Mode) ± 1% / N/A / N/A / N/A
Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz / N/A / N/A / N/A
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz / 50/60 Hz ± 1% / 50/60 Hz ± 1% / 50/60 Hz ± 1%
Current Crest Ratio 3:1 (max.) / N/A / N/A / N/A
Harmonic Distortion ≤ 2% THD (Linear Load) ; ≤ 5 % THD (Non-linear Load) / N/A / N/A / N/A
Transfer Time Zero / N/A / N/A / N/A
Waveform (Batt. Mode) Pure Sine wave / N/A / N/A / N/A
Overload AC Mode 100-110% for 60 min, 111-125% for 10 min, 126%-150% for 1 min; >150% immediately shutdown / N/A / N/A / N/A
Efficiency
AC Mode 95.5% / N/A / N/A / N/A
ECO Mode 98.5% / N/A / N/A / N/A
Battery Mode 94.5%
Battery
Battery Type 12V/9Ah / N/A / N/A / N/A
Numbers (10+10) pcs / (16+16) pcs x 2 / (16+16) pcs x 2 / (16+16) pcs x 2
Standard Model Recharge Time 9 hours recover to 90% capacity / N/A / N/A / N/A
Charging Current (max.) 1A (Default) / 2A (Default) / 2A (Default) / 2A (Default)
Charging Voltage +/-136.5 VDC / +/-218 VDC / +/-218 VDC / +/-218 VDC
Communication
Smart RS-232 / USB Supports Windows® Family, Linux and MAC / N/A / N/A / N/A
Optional SNMP Power management from SNMP manager and web browser / N/A / N/A / N/A
Physical
Standard Model Dimension, DxWxH (mm) 630 x 250 x 826 / 815 x 300 x 1000 / 815 x 300 x 1000 / 815 x 300 x 1000
Net Weight (kgs) 139 / 207 / 207 / 207
Additional Specifications
Weight 139 / 207 / 207 / 207
Operating Conditions
Operation Temperature 0-40°C / N/A / N/A / N/A
Operation Humidity < 95% and non-condensing / N/A / N/A / N/A
Altitude 0 – 1500m at full load / N/A / N/A / N/A

Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.

Availability & grid compliance in Yemen

Market Yemen
Grid authority / regulator Public Electricity Corporation (PEC), Ministry of Electricity and Energy
Quotation currency YER
Support hours timezone Asia/Aden
Delivery & installation coverage Sana'a, Aden, Taiz, Al Hudaydah, Mukalla

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Yemen that is Public Electricity Corporation (PEC), Ministry of Electricity and Energy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Key Features & Technical Highlights

  • True double-conversion: True double-conversion
  • DSP technology guarantees high performance: DSP technology guarantees high performance
  • Output power factor 1: Output power factor 1
  • Active power factor correction in: Active power factor correction in all phases
  • 50Hz/60Hz frequency converter mode: 50Hz/60Hz frequency converter mode
  • Dual AC inputs: Dual AC inputs
  • Emergency power off function (EPO): Emergency power off function (EPO)
  • Generator compatible: Generator compatible
  • Adjustable battery numbers for long-run: Adjustable battery numbers for long-run model
  • Maintenance bypass available: Maintenance bypass available
  • Parallel operation up to 4: Parallel operation up to 4 units with common battery
  • Optional isolation transformer offers full: Optional isolation transformer offers full isolation and complete common mode noise rejection

Frequently Asked Questions

What are the main performance specifications of the Galleon II and III UPS systems?

The Galleon II and III UPS systems offer high efficiency with AC mode at 95.5% and ECO mode at 98.5%. They support a nominal voltage of 3 x 400 VAC and maintain a power factor greater than 0.99 at full load.

Are these UPS systems compatible with different battery types or solar panels?

The Galleon series is designed to be compatible with a wide range of battery types. However, specific compatibility with solar panels should be confirmed with Voltronic Power support.

What are the physical specifications of these UPS systems?

The physical dimensions and weight vary depending on the model. For precise details, please refer to the product manual or contact Voltronic Power.

What are the installation requirements for the Galleon II and III UPS systems?

Installation requires a stable environment with proper ventilation. Ensure the system is connected to a compatible power source and follow the installation guidelines provided in the manual.

What warranty is provided with the Galleon II and III UPS systems?

Voltronic Power typically offers a standard warranty period for their UPS systems. For specific warranty details, please consult the warranty documentation or contact customer support.

What certifications and standards do these UPS systems meet?

The Galleon II and III UPS systems are certified to meet standard industry certifications, ensuring reliable performance and safety.

What are the operating conditions for these UPS systems?

These UPS systems are designed to operate efficiently within a temperature range of 0°C to 40°C and a relative humidity of 0% to 95% non-condensing.

What are the key features and benefits of the Galleon II and III UPS systems?

Key features include zero transfer time, pure sine wave output in battery mode, and robust overload capabilities. These features ensure uninterrupted power supply and protection for sensitive equipment.