Parameter 10K (L)20K (L)30K (L)40K (L)
Input
Nominal Voltage 3 x 400 VAC (3Ph+N) / 230 VAC (1Ph+N)3 x 360/380/400/415 VAC (3Ph+N)
Voltage Range 110-300 VAC ± 3 % @ 50% load; 176-276 VAC ± 3 % @ 100% load305VAC~457VAC
Frequency Range 46-54 Hz or 56-64Hz40-70 Hz
Power Factor > 0.99 @ 100% LoadN/A
Harmonic Distortion (THDi) < 4% at full linear loadN/A
Output
AC Voltage Regulation (Batt. Mode) ± 1%N/A
Frequency Range (Synchronized Range) 46~54Hz or 56~64HzN/A
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz50/60 Hz ± 1%
Current Crest Ratio 3:1 (max.)N/A
Harmonic Distortion ≤ 2% THD (Linear Load) ; ≤ 5 % THD (Non-linear Load)N/A
Transfer Time ZeroN/A
Waveform (Batt. Mode) Pure Sine waveN/A
Overload AC Mode 100-110% for 60 min, 111-125% for 10 min, 126%-150% for 1 min; >150% immediately shutdownN/A
Efficiency
AC Mode 95.5%N/A
ECO Mode 98.5%N/A
Battery Mode 94.5%N/A
Battery
Battery Type 12V/9AhN/A
Numbers (10+10) pcs(16+16) pcs x 2
Standard Model Recharge Time 9 hours recover to 90% capacityN/A
Charging Current (max.) 1A (Default)2A (Default)
Charging Voltage +/-136.5 VDC+/-218 VDC
Physical
Standard Model Dimension, DxWxH (mm) 630 x 250 x 826815 x 300 x 1000
Net Weight (kgs) 139207
Operating Conditions
Operation Temperature 0-40°CN/A
Operation Humidity < 95% and non-condensingN/A
Altitude 0 – 1500m at full loadN/A
Communication
Smart RS-232 / USB Supports Windows® Family, Linux and MACN/A
Optional SNMP Power management from SNMP manager and web browserN/A

Note: Specifications are based on the official Voltronic Power datasheet. Values may be subject to change; always verify against the latest manufacturer documentation.

Key Features

True double-conversion

DSP technology guarantees high performance

Output power factor 1

Active power factor correction in all phases

50Hz/60Hz frequency converter mode

Dual AC inputs

Emergency power off function (EPO)

Generator compatible

Applications & Use Cases

Typical Applications

  • Data centers
  • Hospitals and medical facilities
  • Banks and financial institutions
  • Telecommunications
  • Factories and industrial facilities

Regional Installation Notes (United Arab Emirates)

Climate Suitability: Suitable for United Arab Emirates's hot climate with reliable performance at high temperatures.

  • Ensure adequate ventilation
  • Protection from direct sunlight
  • Regular maintenance recommended

Frequently Asked Questions

What are the main performance specifications of the Galleon II and III UPS systems?

The Galleon II and III UPS systems offer high efficiency with AC mode at 95.5% and ECO mode at 98.5%. They support a nominal voltage of 3 x 400 VAC and maintain a power factor greater than 0.99 at full load.

Are these UPS systems compatible with different battery types or solar panels?

The Galleon series is designed to be compatible with a wide range of battery types. However, specific compatibility with solar panels should be confirmed with Voltronic Power support.

What are the physical specifications of these UPS systems?

The physical dimensions and weight vary depending on the model. For precise details, please refer to the product manual or contact Voltronic Power.

What are the installation requirements for the Galleon II and III UPS systems?

Installation requires a stable environment with proper ventilation. Ensure the system is connected to a compatible power source and follow the installation guidelines provided in the manual.

What warranty is provided with the Galleon II and III UPS systems?

Voltronic Power typically offers a standard warranty period for their UPS systems. For specific warranty details, please consult the warranty documentation or contact customer support.

What certifications and standards do these UPS systems meet?

The Galleon II and III UPS systems are certified to meet standard industry certifications, ensuring reliable performance and safety.

What are the operating conditions for these UPS systems?

These UPS systems are designed to operate efficiently within a temperature range of 0°C to 40°C and a relative humidity of 0% to 95% non-condensing.

What are the key features and benefits of the Galleon II and III UPS systems?

Key features include zero transfer time, pure sine wave output in battery mode, and robust overload capabilities. These features ensure uninterrupted power supply and protection for sensitive equipment.