Voltronic Power AXPERT-MAX-II-6.5KW
The Axpert MAX II 6.5KW is a solar inverter rated 6.5KW. Every figure on this page is read from the manufacturer's manual for the Axpert MAX II series.
Technical Specifications
| Parameter | AXPERT-MAX-II-6.5KW |
|---|---|
| Electrical / AC Output Data | |
| Max AC Input Current | 60A |
| Line Mode Efficiency | >95% (Rated R load, |
| Low Line Disconnect | 90Vac±7V (UPS) 80Vac±7V (Appliances) |
| Low Line Re-connect | 100Vac±7V (UPS); 90Vac±7V (Appliances) |
| High Line Disconnect | 140Vac±7V |
| High Line Re-connect | 135Vac±7V |
| AC Input Voltage | 150Vac |
| Grid / AC Frequency | 50Hz/60Hz ( |
| Transfer / Switchover Time | 10ms typical 20ms typical ( |
| Additional Specifications | |
| Nominal Input Voltage | 120Vac |
| Low Loss Frequency | 40± |
| Low Loss Return Frequency | 42± |
| High Loss Frequency | 65± |
| High Loss Return Frequency | 63± |
| Output Short Circuit Protection | Line mode: Circuit Battery mode: |
| Max. Input Current | 18A x |
| Max. PV Array Open Circuit Voltage | 250Vdc |
| PV Array MPPT Voltage Range | 90Vdc~230Vdc |
| Safety Compliance | UL |
| Max parallel numbers | 6 |
| Power Unbalance Ratio | <5% @ 100% Load |
| Floating Charging Voltage | 54Vdc |
| Peak Efficiency | 93% |
| Surge Capacity | 2* rated power for 5 seconds |
| Low DC Cut-off Voltage | 44Vdc |
| Nominal DC Input Voltage | 48Vdc |
| Parallel communication | CAN |
| Parallel Kit | YES |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Yemen
| Market | Yemen |
| Grid authority / regulator | Public Electricity Corporation (PEC), Ministry of Electricity and Energy |
| Quotation currency | YER |
| Support hours timezone | Asia/Aden |
| Delivery & installation coverage | Sana'a, Aden, Taiz, Al Hudaydah, Mukalla |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Yemen that is Public Electricity Corporation (PEC), Ministry of Electricity and Energy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.