Voltronic Power AXPERT-MAX-II-6.5KW
The Axpert MAX II 6.5KW is a solar inverter rated 6.5KW. Every figure on this page is read from the manufacturer's manual for the Axpert MAX II series.
Technical Specifications
| Parameter | AXPERT-MAX-II-6.5KW |
|---|---|
| Electrical / AC Output Data | |
| Max AC Input Current | 60A |
| Line Mode Efficiency | >95% (Rated R load, |
| Low Line Disconnect | 90Vac±7V (UPS) 80Vac±7V (Appliances) |
| Low Line Re-connect | 100Vac±7V (UPS); 90Vac±7V (Appliances) |
| High Line Disconnect | 140Vac±7V |
| High Line Re-connect | 135Vac±7V |
| AC Input Voltage | 150Vac |
| Grid / AC Frequency | 50Hz/60Hz ( |
| Transfer / Switchover Time | 10ms typical 20ms typical ( |
| Additional Specifications | |
| Nominal Input Voltage | 120Vac |
| Low Loss Frequency | 40± |
| Low Loss Return Frequency | 42± |
| High Loss Frequency | 65± |
| High Loss Return Frequency | 63± |
| Output Short Circuit Protection | Line mode: Circuit Battery mode: |
| Max. Input Current | 18A x |
| Max. PV Array Open Circuit Voltage | 250Vdc |
| PV Array MPPT Voltage Range | 90Vdc~230Vdc |
| Safety Compliance | UL |
| Max parallel numbers | 6 |
| Power Unbalance Ratio | <5% @ 100% Load |
| Floating Charging Voltage | 54Vdc |
| Peak Efficiency | 93% |
| Surge Capacity | 2* rated power for 5 seconds |
| Low DC Cut-off Voltage | 44Vdc |
| Nominal DC Input Voltage | 48Vdc |
| Parallel communication | CAN |
| Parallel Kit | YES |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Sudan
| Market | Sudan |
| Grid authority / regulator | Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum |
| Quotation currency | SDG |
| Support hours timezone | Africa/Khartoum |
| Delivery & installation coverage | Khartoum, Omdurman, Port Sudan, Kassala, Nyala |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Sudan that is Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.