Voltronic Power AXPERT-MAX-3.6/7.2KW
The Axpert MAX 3.6KW is a solar charge controller rated 3.6KW. Every figure on this page is read from the manufacturer's manual for the Axpert MAX series.
Technical Specifications
| Parameter | AXPERT-MAX-3.6KW | AXPERT-MAX-7.2KW |
|---|---|---|
| Electrical / AC Output Data | ||
| DC Offset | ≤100mV | |
| Rated Output Power | 3600W | 7200W |
| Max Efficiency | 91% | 93% |
| Battery Data | ||
| High DC Cut-off Voltage | 33Vdc | 66Vdc |
| Low DC Cut-off Voltage | 22Vdc | 44Vdc |
| Additional Specifications | ||
| Nominal DC Input Voltage | 24Vdc | |
| High DC Recovery Voltage | 32Vdc | |
| Max parallel numbers | 6 | |
| Surge Capacity | 2* rated power for 5 seconds | |
| Storage temperature | -15°C~ 60°C | |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Yemen
| Market | Yemen |
| Grid authority / regulator | Public Electricity Corporation (PEC), Ministry of Electricity and Energy |
| Quotation currency | YER |
| Support hours timezone | Asia/Aden |
| Delivery & installation coverage | Sana'a, Aden, Taiz, Al Hudaydah, Mukalla |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Yemen that is Public Electricity Corporation (PEC), Ministry of Electricity and Energy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.