Voltronic IMASTER-SP
Discover the iMaster Solar Pump Inverter by Voltronic Power with AC input voltage 220V-240V and DC voltage 450VDC for efficient solar pumping.
Technical Specifications
| Parameter | VOLTRONIC-IMASTER-SP |
|---|---|
| Input | |
| Input Voltage | AC,1PH,220V(-15%) ~ 240V(+10%) / AC,3PH,380V(-15%) ~ 440V(+10%) / AC,3PH,380V(-15%) ~ 440V(+10%) / AC,3PH,380V(-15%) ~ 440V(+10%) / AC,3PH,380V(-15%) ~ 440V(+10%) / AC,3PH,380V(-15%) ~ 440V(+10%) / AC,3PH,380V(-15%) ~ 440V(+10%) / AC,3PH,380V(-15%) ~ 440V(+10%) / AC,3PH,380V(-15%) ~ 440V(+10%) / AC,3PH,380V(-15%) ~ 440V(+10%) / AC,3PH,380V(-15%) ~ 440V(+10%) / AC,3PH,380V(-15%) ~ 440V(+10%) / AC,3PH,380V(-15%) ~ 440V(+10%) / AC,3PH,380V(-15%) ~ 440V(+10%) / AC,3PH,380V(-15%) ~ 440V(+10%) / AC,3PH,380V(-15%) ~ 440V(+10%) / AC,3PH,380V(-15%) ~ 440V(+10%) |
| Rated Frequency | 50/60 Hz |
| Frequency Range | ±5% (47.5 ~ 63Hz) |
| DC Input | |
| Input DC Voltage | 450VDC / 900VDC / 900VDC / 900VDC / 900VDC / 900VDC / 900VDC / 900VDC / 900VDC / 900VDC / 900VDC / 900VDC / 900VDC / 900VDC / 900VDC / 900VDC / 900VDC |
| Recommended VOC Voltage Range | 360 ~ 430VDC / 550 ~ 750VDC / 550 ~ 750VDC / 550 ~ 750VDC / 550 ~ 750VDC / 550 ~ 750VDC / 550 ~ 750VDC / 550 ~ 750VDC / 550 ~ 750VDC / 550 ~ 750VDC / 550 ~ 750VDC / 550 ~ 750VDC / 550 ~ 750VDC / 550 ~ 750VDC / 550 ~ 750VDC / 550 ~ 750VDC / 550 ~ 750VDC |
| Recommended MPPT | 250 ~ 350VDC / 450 ~ 600VDC / 450 ~ 600VDC / 450 ~ 600VDC / 450 ~ 600VDC / 450 ~ 600VDC / 450 ~ 600VDC / 450 ~ 600VDC / 450 ~ 600VDC / 450 ~ 600VDC / 450 ~ 600VDC / 450 ~ 600VDC / 450 ~ 600VDC / 450 ~ 600VDC / 450 ~ 600VDC / 450 ~ 600VDC / 450 ~ 600VDC |
| Voltage Range | 160 ~ 450VDC (parameter adjustable) / 300 ~ 900VDC (parameter adjustable) / 300 ~ 900VDC (parameter adjustable) / 300 ~ 900VDC (parameter adjustable) / 300 ~ 900VDC (parameter adjustable) / 300 ~ 900VDC (parameter adjustable) / 300 ~ 900VDC (parameter adjustable) / 300 ~ 900VDC (parameter adjustable) / 300 ~ 900VDC (parameter adjustable) / 300 ~ 900VDC (parameter adjustable) / 300 ~ 900VDC (parameter adjustable) / 300 ~ 900VDC (parameter adjustable) / 300 ~ 900VDC (parameter adjustable) / 300 ~ 900VDC (parameter adjustable) / 300 ~ 900VDC (parameter adjustable) / 300 ~ 900VDC (parameter adjustable) / 300 ~ 900VDC (parameter adjustable) |
| Output | |
| Output Voltage | 0- Input Voltage |
| Maximum Output Frequency | 0.1 ~ 500Hz |
| Control | |
| Control Mode | Open-loop vector control (SVC) ; V/F control |
| Starting Torque | 0.5Hz/150% (SVC) |
| Speed Control Accuracy | ±0.5% (SVC) |
| Communication | |
| Communication Port | RS-485 |
| Mechanical Data | |
| Dimensions (mm) | PC10-0.75G-S2: 67.3 x 157.5 x 171 / PC10-1.5G-S2: 85 x 184 x 197.5 / PC10-2.2G-S2: 106 x 233 x 245 / PC10-4.0G-S2: 106 x 233 x 245 / PC10-5.5G-S2: 106 x 233 x 245 / PC10-0.75G-T4: 67.3 x 157.5 x 171 / PC10-1.5G-T4: 85 x 184 x 197.5 / PC10-2.2G-T4: 106 x 233 x 245 / PC10-3.7G-T4: 106 x 233 x 245 / PC10-5.5G-T4: 106 x 233 x 245 / PC10-7.5G-T4: 106 x 233 x 245 / PC10-11G-T4: 147 x 298 x 310 / PC10-15G-T4: 147 x 298 x 310 / PC10-18.5G-T4: 147 x 298 x 310 / PC10-22G-T4: 147 x 298 x 310 / PC10-30G-T4: 260 x 433.5 x 450 / PC10-37G-T4: 260 x 433.5 x 450 |
| Weight (kg) | PC10-0.75G-S2: 1 / PC10-1.5G-S2: 1.5 / PC10-2.2G-S2: 3.5 / PC10-4.0G-S2: 3.5 / PC10-5.5G-S2: 3.5 / PC10-0.75G-T4: 1 / PC10-1.5G-T4: 1.5 / PC10-2.2G-T4: 3.5 / PC10-3.7G-T4: 3.5 / PC10-5.5G-T4: 3.5 / PC10-7.5G-T4: 3.5 / PC10-11G-T4: 5.5 / PC10-15G-T4: 5.5 / PC10-18.5G-T4: 5.5 / PC10-22G-T4: 5.5 / PC10-30G-T4: 15.5 / PC10-37G-T4: 15.5 |
| Protection Features | |
| Protective Function | Power-on motor short circuit detection, output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection, overheat protection, overload protection, underload protection, weak light protection, etc. |
| Operating Conditions | |
| Storage Temperature | -20°C ~ 60°C |
| Operation Temperature | -10°C ~ 50°C (If temperature is higher than 40°C, the output capacity will be derated 1% per 1°C increase) |
| Operation Humidity | < 95% RH |
| Noise Level | 50dBA max (0.75G-7.5G) / 65dBA max (11G-37G) |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Sudan
| Market | Sudan |
| Grid authority / regulator | Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum |
| Quotation currency | SDG |
| Support hours timezone | Africa/Khartoum |
| Delivery & installation coverage | Khartoum, Omdurman, Port Sudan, Kassala, Nyala |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Sudan that is Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- Built-in maximum power point tracking: Built-in maximum power point tracking (MPPT) algorithm
- Strong anti-interference capabilities: Strong anti-interference capabilities
- V/F Control, Sensor-less Vector Control: V/F Control, Sensor-less Vector Control (SVC) and Feedback Vector Control (FVC) selectable
- Automatic torque boost and slip: Automatic torque boost and slip compensation
- Built-in RS-485 MODBUS communication: Built-in RS-485 MODBUS communication
- Supports an external keypad: Supports an external keypad
Frequently Asked Questions
What are the main performance specifications of the iMaster Solar Pump Inverter?
The iMaster Solar Pump Inverter operates with an input voltage of AC, 1PH, 220V(-15%) ~ 240V(+10%) and a rated frequency of 50/60 Hz. It supports a frequency range of ±5% (47.5 ~ 63Hz) and offers a maximum output frequency of 0.1 ~ 500Hz.
Is the iMaster Solar Pump Inverter compatible with different battery types and solar panels?
The inverter is designed to work with solar panels within a recommended VOC voltage range of 360 ~ 430VDC and MPPT range of 250 ~ 350VDC. It does not directly support battery connections as it is primarily intended for solar pump applications.
What are the physical specifications of the iMaster Solar Pump Inverter?
The specific dimensions and weight of the iMaster Solar Pump Inverter are not provided in the key specifications. However, it is designed to be robust and suitable for various installation environments.
What are the installation requirements for the iMaster Solar Pump Inverter?
Installation should ensure the inverter is mounted in a location that maintains an operation temperature between -10°C and 50°C. If the temperature exceeds 40°C, the output capacity will be derated by 1% per 1°C increase.
What warranty is offered with the iMaster Solar Pump Inverter?
Voltronic Power typically offers a standard warranty for their products, but specific warranty terms for the iMaster Solar Pump Inverter should be confirmed with the retailer or distributor.
What certifications and standards does the iMaster Solar Pump Inverter comply with?
The inverter complies with IEC 61800-5-1 and IEC 61800-3(C3) standards and is RoHS compliant, ensuring it meets international safety and environmental standards.
What are the operating conditions for the iMaster Solar Pump Inverter?
The inverter operates optimally within a temperature range of -10°C to 50°C and can be stored at temperatures between -20°C and 60°C. It includes protective functions to handle various environmental conditions.
What are the key features and benefits of the iMaster Solar Pump Inverter?
Key features include open-loop vector control (SVC) and V/F control, with a starting torque of 0.5Hz/150% (SVC). It offers comprehensive protective functions, ensuring reliable performance in diverse conditions.