Voltronic iMaster Solar Pump Inverter
The iMaster Solar Pump Inverter by Voltronic Power is a cutting-edge solution for solar-powered water pumping systems. Designed to handle AC input voltages from 220V to 240V and a DC input voltage of 450VDC, this inverter ensures optimal performance and reliability.
Technical Specifications
| Parameter | PC10-0.75G-S2 | PC10-1.5G-S2 | PC10-2.2G-S2 | PC10-4.0G-S2 | PC10-5.5G-S2 | PC10-0.75G-T4 | PC10-1.5G-T4 | PC10-2.2G-T4 | PC10-3.7G-T4 | PC10-5.5G-T4 | PC10-7.5G-T4 | PC10-11G-T4 | PC10-15G-T4 | PC10-18.5G-T4 | PC10-22G-T4 | PC10-30G-T4 | PC10-37G-T4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Input | |||||||||||||||||
| Input Voltage | AC,1PH,220V(-15%) ~ 240V(+10%) | AC,3PH,380V(-15%) ~ 440V(+10%) | |||||||||||||||
| Rated Frequency | 50/60 Hz | ||||||||||||||||
| Frequency Range | ±5% (47.5 ~ 63Hz) | ||||||||||||||||
| DC Input | |||||||||||||||||
| Input DC Voltage | 450VDC | 900VDC | |||||||||||||||
| Recommended VOC Voltage Range | 360 ~ 430VDC | 550 ~ 750VDC | |||||||||||||||
| Recommended MPPT | 250 ~ 350VDC | 450 ~ 600VDC | |||||||||||||||
| Voltage Range | 160 ~ 450VDC (parameter adjustable) | 300 ~ 900VDC (parameter adjustable) | |||||||||||||||
| Output | |||||||||||||||||
| Output Voltage | 0- Input Voltage | ||||||||||||||||
| Maximum Output Frequency | 0.1 ~ 500Hz | ||||||||||||||||
| Control | |||||||||||||||||
| Control Mode | Open-loop vector control (SVC) ; V/F control | ||||||||||||||||
| Starting Torque | 0.5Hz/150% (SVC) | ||||||||||||||||
| Speed Control Accuracy | ±0.5% (SVC) | ||||||||||||||||
| Protection Features | |||||||||||||||||
| Protective Function | Power-on motor short circuit detection, output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection, overheat protection, overload protection, underload protection, weak light protection, etc. | ||||||||||||||||
| Operating Conditions | |||||||||||||||||
| Storage Temperature | -20°C ~ 60°C | ||||||||||||||||
| Operation Temperature | -10°C ~ 50°C (If temperature is higher than 40°C, the output capacity will be derated 1% per 1°C increase) | ||||||||||||||||
| Operation Humidity | < 95% RH | ||||||||||||||||
| Noise Level | 50dBA max (0.75G-7.5G) / 65dBA max (11G-37G) | ||||||||||||||||
| Communication | |||||||||||||||||
| Communication Port | RS-485 | ||||||||||||||||
| Mechanical Data | |||||||||||||||||
| Dimensions (mm) | PC10-0.75G-S2: 67.3 x 157.5 x 171 | PC10-1.5G-S2: 85 x 184 x 197.5 | PC10-2.2G-S2: 106 x 233 x 245 | PC10-4.0G-S2: 106 x 233 x 245 | PC10-5.5G-S2: 106 x 233 x 245 | PC10-0.75G-T4: 67.3 x 157.5 x 171 | PC10-1.5G-T4: 85 x 184 x 197.5 | PC10-2.2G-T4: 106 x 233 x 245 | PC10-3.7G-T4: 106 x 233 x 245 | PC10-5.5G-T4: 106 x 233 x 245 | PC10-7.5G-T4: 106 x 233 x 245 | PC10-11G-T4: 147 x 298 x 310 | PC10-15G-T4: 147 x 298 x 310 | PC10-18.5G-T4: 147 x 298 x 310 | PC10-22G-T4: 147 x 298 x 310 | PC10-30G-T4: 260 x 433.5 x 450 | PC10-37G-T4: 260 x 433.5 x 450 |
| Weight (kg) | PC10-0.75G-S2: 1 | PC10-1.5G-S2: 1.5 | PC10-2.2G-S2: 3.5 | PC10-4.0G-S2: 3.5 | PC10-5.5G-S2: 3.5 | PC10-0.75G-T4: 1 | PC10-1.5G-T4: 1.5 | PC10-2.2G-T4: 3.5 | PC10-3.7G-T4: 3.5 | PC10-5.5G-T4: 3.5 | PC10-7.5G-T4: 3.5 | PC10-11G-T4: 5.5 | PC10-15G-T4: 5.5 | PC10-18.5G-T4: 5.5 | PC10-22G-T4: 5.5 | PC10-30G-T4: 15.5 | PC10-37G-T4: 15.5 |
Note: Specifications are based on the official Voltronic Power datasheet. Values may be subject to change; always verify against the latest manufacturer documentation.
Key Features
Built-in maximum power point tracking (MPPT) algorithm
Strong anti-interference capabilities
V/F Control, Sensor-less Vector Control (SVC) and Feedback Vector Control (FVC) selectable
Automatic torque boost and slip compensation
Built-in RS-485 MODBUS communication
Supports an external keypad
Applications & Use Cases
Typical Applications
- Residential applications
- Commercial projects
- Industrial applications
- Backup power systems
Regional Installation Notes (United Arab Emirates)
Climate Suitability: Suitable for United Arab Emirates's hot climate with reliable performance at high temperatures.
- Ensure adequate ventilation
- Protection from direct sunlight
- Regular maintenance recommended
Frequently Asked Questions
What are the main performance specifications of the iMaster Solar Pump Inverter?
The iMaster Solar Pump Inverter operates with an input voltage of AC, 1PH, 220V(-15%) ~ 240V(+10%) and a rated frequency of 50/60 Hz. It supports a frequency range of ±5% (47.5 ~ 63Hz) and offers a maximum output frequency of 0.1 ~ 500Hz.
Is the iMaster Solar Pump Inverter compatible with different battery types and solar panels?
The inverter is designed to work with solar panels within a recommended VOC voltage range of 360 ~ 430VDC and MPPT range of 250 ~ 350VDC. It does not directly support battery connections as it is primarily intended for solar pump applications.
What are the physical specifications of the iMaster Solar Pump Inverter?
The specific dimensions and weight of the iMaster Solar Pump Inverter are not provided in the key specifications. However, it is designed to be robust and suitable for various installation environments.
What are the installation requirements for the iMaster Solar Pump Inverter?
Installation should ensure the inverter is mounted in a location that maintains an operation temperature between -10°C and 50°C. If the temperature exceeds 40°C, the output capacity will be derated by 1% per 1°C increase.
What warranty is offered with the iMaster Solar Pump Inverter?
Voltronic Power typically offers a standard warranty for their products, but specific warranty terms for the iMaster Solar Pump Inverter should be confirmed with the retailer or distributor.
What certifications and standards does the iMaster Solar Pump Inverter comply with?
The inverter complies with IEC 61800-5-1 and IEC 61800-3(C3) standards and is RoHS compliant, ensuring it meets international safety and environmental standards.
What are the operating conditions for the iMaster Solar Pump Inverter?
The inverter operates optimally within a temperature range of -10°C to 50°C and can be stored at temperatures between -20°C and 60°C. It includes protective functions to handle various environmental conditions.
What are the key features and benefits of the iMaster Solar Pump Inverter?
Key features include open-loop vector control (SVC) and V/F control, with a starting torque of 0.5Hz/150% (SVC). It offers comprehensive protective functions, ensuring reliable performance in diverse conditions.