Voltronic Power Solutions

Voltronic GIANT-II-3P-3P

Discover the Voltronic Power Giant II 3P/3P UPS with 6 pulse rectifier and 380VAC/400VAC/415VAC nominal voltage for reliable power solutions.

Models Covered: VOLTRONIC-GIANT-II-3P-3P

Manufacturer: Voltronic Power Technology Corp.

Application: The Voltronic Power Giant II 3P/3P UPS is engineered to deliver robust and reliable power management solutions. With a 6 pulse rectifier and a nominal voltage range of 380VAC to 415VAC, it ensures optimal performance for critical applications. Ideal for data centers, industrial facilities, and telecommunications, the Giant II 3P/3P UPS provides consistent power protection and efficiency.

Technical Specifications

Technical Specifications
Parameter VOLTRONIC-GIANT-II-3P-3P
Electrical Data
Rectifier Type 6 pulse / 6 pulse / 6 pulse / 6 pulse / 6 pulse / 6 pulse / 12 pulse / 12 pulse / 12 pulse / 12 pulse
Input
Nominal Voltage 380VAC/400VAC/415VAC
Acceptable Voltage Range 304VAC – 456VAC
Frequency 50Hz ± 10%
TVSS 40kA (optional)
Bypass
Input Voltage Range 285VAC – 475VAC
Battery
Battery Voltage 384 VDC (adjustable)
Cold Start Yes
Output
Power Factor 0.9, customized up to 1.0
Nominal Output Voltage 380VAC/400VAC/415VAC
Output Voltage Regulation ±1%
Overload Capability 110% continuous running; 125% for 10 min; >150% for 1 min
Communication
Dry Contacts 5 outputs and 4 inputs
Optional SNMP Power management from SNMP manager and web browser
Modbus RS-232/RS-485 Supports Windows® family, Linux and MAC
Certifications
Safety IEC62040-1:2017
Physical
IP Protection IP31 (default), IP42 (optional)
Dimensions (DxWxH) mm 656 x 405 x 817 / 656 x 405 x 941 / 818 x 432 x 1159 / 971 x 554 x 1290 / 971 x 635 x 1326 / 1051 x 705 x 1646 / 1051 x 705 x 1646 / 1051 x 705 x 1646 / 1051 x 705 x 1646 / 1051 x 705 x 1646
Mechanical Data
Net Weight (Kgs) 120 / 145 / 193 / 278 / 365 / 471 / 573 / 650 / 735 / 790
Additional Specifications
Weight 120 / 145 / 193 / 278 / 365 / 471 / 573 / 650 / 735 / 790
Operating Conditions
Operating Temperature 0 – 50°C
Storage Temperature -25°C – 55°C
Humidity 0–95% (non-condensing)
Altitude 1000m

Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.

Availability & grid compliance in Sudan

Market Sudan
Grid authority / regulator Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum
Quotation currency SDG
Support hours timezone Africa/Khartoum
Delivery & installation coverage Khartoum, Omdurman, Port Sudan, Kassala, Nyala

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Sudan that is Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Key Features & Technical Highlights

  • True online double conversion with: True online double conversion with DSP control
  • Output power factor 0.9, customized: Output power factor 0.9, customized up to 1.0
  • Galvanic isolation eliminates common mode: Galvanic isolation eliminates common mode noise
  • Conformal coating ensures operation stability: Conformal coating ensures operation stability
  • Standard IP31 protection, optional IP42: Standard IP31 protection, optional IP42
  • Sustains long-term operation for all: Sustains long-term operation for all types of loads
  • Redundant design for reliability: Redundant design for reliability
  • Temperature compensation to prolong battery: Temperature compensation to prolong battery life
  • Backfeed protection guarantees safety operation: Backfeed protection guarantees safety operation
  • 7” touch color LCD with: 7” touch color LCD with customized control setting
  • Accepts dual-mains inputs: Accepts dual-mains inputs
  • Parallel capability up to 4: Parallel capability up to 4 units

Frequently Asked Questions

What are the main performance specifications of the Giant II 3P/3P UPS?

The Giant II 3P/3P UPS features a power factor of 0.9, which can be customized up to 1.0. It operates with a nominal voltage of 380VAC/400VAC/415VAC and maintains output voltage regulation within ±1%.

Is the Giant II 3P/3P UPS compatible with different battery types or solar panels?

The UPS is designed to work with a battery voltage of 384 VDC, which is adjustable. It does not directly support solar panels but can be integrated into systems that include solar power with appropriate converters.

What are the physical specifications of the Giant II 3P/3P UPS?

The dimensions of the UPS are 656 x 405 x 817 mm. It has an IP31 protection rating by default, with an optional upgrade to IP42 for enhanced protection.

What are the installation requirements for the Giant II 3P/3P UPS?

Installation requires a stable environment with an input voltage range of 285VAC to 475VAC. Ensure adequate space for ventilation and maintenance access.

What warranty is offered with the Giant II 3P/3P UPS?

Voltronic Power typically offers a standard warranty period for their UPS products, but specific terms should be confirmed with the retailer or distributor.

What certifications and standards does the Giant II 3P/3P UPS comply with?

The UPS complies with the IEC62040-1:2017 standard, ensuring it meets international safety and performance requirements.

What are the operating conditions for the Giant II 3P/3P UPS?

The UPS is designed to operate efficiently within a frequency range of 50Hz ± 10%. It should be used in environments with controlled temperature and humidity to ensure optimal performance.

What are the key features and benefits of the Giant II 3P/3P UPS?

Key features include a cold start capability and overload capability of 110% continuous running, 125% for 10 minutes, and over 150% for 1 minute. These features ensure reliability and flexibility in power management.