Voltronic GALLEON-II
Discover Voltronic Power's Galleon II Online UPS with versatile voltage options and precise regulation for optimal power protection.
Technical Specifications
| Parameter | VOLTRONIC-GALLEON-II |
|---|---|
| Input | |
| Nominal Voltage | 100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC |
| Voltage Range | 55 - 150 VAC ± 5% or 110 - 300 VAC ± 5% @ 50% load / 55 - 150 VAC ± 5% or 110 - 300 VAC ± 5% @ 50% load / 55 - 150 VAC ± 5% or 110 - 300 VAC ± 5% @ 50% load / 55 - 150 VAC ± 5% or 110 - 300 VAC ± 5% @ 50% load / 55 - 150 VAC ± 5% or 110 - 300 VAC ± 5% @ 50% load / 55 - 150 VAC ± 5% or 110 - 300 VAC ± 5% @ 50% load / 55 - 150 VAC ± 5% or 110 - 300 VAC ± 5% @ 50% load / 55 - 150 VAC ± 5% or 110 - 300 VAC ± 5% @ 50% load |
| Frequency Range | 40 Hz ~ 70 Hz / 40 Hz ~ 70 Hz / 40 Hz ~ 70 Hz / 40 Hz ~ 70 Hz / 40 Hz ~ 70 Hz / 40 Hz ~ 70 Hz / 40 Hz ~ 70 Hz / 40 Hz ~ 70 Hz |
| Power Factor | ≥ 0.99 @ Nominal Voltage (100% Load) / ≥ 0.99 @ Nominal Voltage (100% Load) / ≥ 0.99 @ Nominal Voltage (100% Load) / ≥ 0.99 @ Nominal Voltage (100% Load) / ≥ 0.99 @ Nominal Voltage (100% Load) / ≥ 0.99 @ Nominal Voltage (100% Load) / ≥ 0.99 @ Nominal Voltage (100% Load) / ≥ 0.99 @ Nominal Voltage (100% Load) |
| Output | |
| Output Voltage | 100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC |
| AC Voltage Regulation (Batt. Mode) | ± 1% / ± 1% / ± 1% / ± 1% / ± 1% / ± 1% / ± 1% / ± 1% |
| Harmonic Distortion | ≤ 2 % THD (Linear Load) ; ≤ 4 % THD (Non-linear Load) / ≤ 2 % THD (Linear Load) ; ≤ 4 % THD (Non-linear Load) / ≤ 2 % THD (Linear Load) ; ≤ 4 % THD (Non-linear Load) / ≤ 2 % THD (Linear Load) ; ≤ 4 % THD (Non-linear Load) / ≤ 2 % THD (Linear Load) ; ≤ 4 % THD (Non-linear Load) / ≤ 2 % THD (Linear Load) ; ≤ 4 % THD (Non-linear Load) / ≤ 2 % THD (Linear Load) ; ≤ 4 % THD (Non-linear Load) / ≤ 2 % THD (Linear Load) ; ≤ 4 % THD (Non-linear Load) |
| Transfer Time | 0 ms |
| Waveform (Batt. Mode) | Pure Sinewave |
| Electrical Data | |
| Frequency Range (Synchronized Range) | 47 ~ 53 Hz or 57 ~ 63 Hz / 47 ~ 53 Hz or 57 ~ 63 Hz / 47 ~ 53 Hz or 57 ~ 63 Hz / 47 ~ 53 Hz or 57 ~ 63 Hz / 57 ~ 63 Hz or 47 ~ 53 Hz / 57 ~ 63 Hz or 47 ~ 53 Hz / 57 ~ 63 Hz or 47 ~ 53 Hz / 57 ~ 63 Hz or 47 ~ 53 Hz |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz / 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz / 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz / 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz / 60Hz ± 0.1Hz or 50 Hz ± 0.1Hz / 60Hz ± 0.1Hz or 50 Hz ± 0.1Hz / 60Hz ± 0.1Hz or 50 Hz ± 0.1Hz / 60Hz ± 0.1Hz or 50 Hz ± 0.1Hz |
| Current Crest Ratio | 3:1 / 3:1 / 3:1 / 3:1 / 3:1 (max.) / 3:1 (max.) / 3:1 (max.) / 3:1 (max.) |
| AC Mode | 90% / 90% / 91% / 91% / 90% / 90% / 91% / 91% |
| Battery Type | 12 V / 7 Ah / 12 V / 9 Ah / 12 V / 7 Ah / 12 V / 7 Ah / 12 V / 7 Ah / 12 V / 9 Ah / 12 V / 7 Ah / 12 V / 7 Ah |
| Numbers | 3 / 3 / 6 / 8 / 2 / 3 / 6 / 6 |
| Charging Current (max.) | 1.5A / 1.5A / 1.2A / 1.2A / 1.5A* / 1.5A* / 1.5A* / 1.5A* |
| Charging Voltage | 41.0 VDC ± 1% / 41.0 VDC ± 1% / 82.1 VDC ± 1% / 109.6 VDC ± 1% / 27.4 VDC ± 1%, 41.1 VDC ± 1% / 41.1 VDC ± 1% / 54.8 VDC ± 1%, 82.1 VDC ± 1% / 82.1 VDC ± 1% |
| Efficiency | |
| ECO Mode | 97% |
| Battery | |
| Typical Recharge Time | 4 hours recover to 90% capacity |
| Communication | |
| Smart RS-232/USB | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC |
| Mechanical Data | |
| Dimension, D×W×H (mm) | 397 × 145 × 220 / 397 × 145 × 220 / 421 × 190 × 318 / 421 × 190 × 318 / 410 × 438 × 88 / 410 × 438 × 88 / 510 × 438 × 88 / 630 × 438 × 88 |
| Net Weight (kgs) | 12.8 / 13.8 / 26.6 / 32.2 / 11.6 / 14.2 / 26.9 / 27.4 |
| Additional Specifications | |
| Weight | 12.8 / 13.8 / 26.6 / 32.2 / 11.6 / 14.2 / 26.9 / 27.4 |
| Operating Conditions | |
| Humidity | 20-95 % RH @ 0- 40°C (Non-condensing) / 20-95 % RH @ 0- 40°C (Non-condensing) / 20-95 % RH @ 0- 40°C (Non-condensing) / 20-95 % RH @ 0- 40°C (Non-condensing) / 20-90 % RH @ 0- 40°C (Non-condensing) / 20-90 % RH @ 0- 40°C (Non-condensing) / 20-90 % RH @ 0- 40°C (Non-condensing) / 20-90 % RH @ 0- 40°C (Non-condensing) |
| Noise Level | Less than 50dB @1Meter |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Sudan
| Market | Sudan |
| Grid authority / regulator | Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum |
| Quotation currency | SDG |
| Support hours timezone | Africa/Khartoum |
| Delivery & installation coverage | Khartoum, Omdurman, Port Sudan, Kassala, Nyala |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Sudan that is Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- True double-conversion: True double-conversion
- Input power factor correction 0.99: Input power factor correction 0.99
- Output power factor 0.9: Output power factor 0.9
- 50Hz/60Hz frequency converter mode: 50Hz/60Hz frequency converter mode
- Programmable power management outlets: Programmable power management outlets
- Emergency power off function (EPO): Emergency power off function (EPO)
- ECO mode operation for energy: ECO mode operation for energy saving
- Very high surge immunity up: Very high surge immunity up to 7KV, 13KA, 1300J
- Generator compatible: Generator compatible
- High overload capability and enhanced: High overload capability and enhanced short circuit protection
- SNMP/USB/RS-232 multiple communications: SNMP/USB/RS-232 multiple communications
- 3-stage smart charging design: 3-stage smart charging design
Frequently Asked Questions
What are the main performance specifications of the Galleon II?
The Galleon II offers high efficiency with 90% in AC mode and 97% in ECO mode. It supports a nominal voltage range of 100/110/115/120/127 VAC or 200/208/220/230/240 VAC, and a power factor of ≥ 0.99 at nominal voltage with 100% load.
Is the Galleon II compatible with different battery types?
Yes, the Galleon II uses a 12 V / 7 Ah battery type, making it compatible with standard UPS battery configurations.
What are the physical specifications of the Galleon II?
The Galleon II's physical dimensions and weight are designed for easy installation, but specific details such as IP rating are not provided in the key specifications.
What are the installation requirements for the Galleon II?
Installation requires a stable environment with a voltage range of 55 - 150 VAC or 110 - 300 VAC at 50% load. Ensure proper ventilation and adherence to safety standards.
What warranty is provided with the Galleon II?
The Galleon II comes with a standard warranty, details of which can be obtained from the retailer or Voltronic Power's customer service.
What certifications and standards does the Galleon II meet?
The Galleon II complies with standard certifications, ensuring reliability and safety in various operational environments.
What are the operating conditions for the Galleon II?
The Galleon II operates efficiently within a frequency range of 40 Hz to 70 Hz and maintains performance in various temperature and humidity conditions.
What are the key features and benefits of the Galleon II?
Key features include zero transfer time, pure sinewave output in battery mode, and low harmonic distortion, making it ideal for sensitive electronic equipment.