Voltronic GALLEON-III
Discover the Galleon III UPS by Voltronic Power with 208-240 VAC output and precise voltage regulation for reliable power protection.
Technical Specifications
| Parameter | VOLTRONIC-GALLEON-III |
|---|---|
| Input | |
| Nominal Voltage | 208/220/230/240 VAC / 208/220/230/240 VAC |
| Voltage Range | 110~300VAC ± 3% at 60% load; 176~300VAC ± 3% at 100% load / 110~300VAC ± 3% at 60% load; 176~300VAC ± 3% at 100% load |
| Frequency Range | 46~54 Hz or 56~64 Hz / 46~54 Hz or 56~64 Hz |
| Power Factor | ≥ 0.99 @ full load / ≥ 0.99 @ full load |
| THDi | < 4% @100% R load / < 4% @100% R load |
| Output | |
| Output Voltage | 208/220/230/240 VAC / 208/220/230/240 VAC |
| AC Voltage Regulation (Batt. Mode) | ± 1% / ± 1% |
| Frequency Range (Synchronized Range) | 46~54 Hz or 56~64 Hz / 46~54 Hz or 56~64 Hz |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz / 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
| Current Crest Ratio | 3:1 (max.) / 3:1 (max.) |
| Harmonic Distortion | ≤ 1 % THD (Linear Load) ; ≤ 4 % THD (Non-linear Load) / ≤ 1 % THD (Linear Load) ; ≤ 4 % THD (Non-linear Load) |
| Transfer Time | 0 / 0 ms |
| Waveform (Batt. Mode) | Pure Sinewave / Pure Sinewave |
| Overload | 100-110% for 60 min, 110-125% for 10 min, 125%-150% 1min, >150% immediately switch to bypass / 100-110% for 60 min, 110-125% for 10 min, 125%-150% 1min, >150% immediately switch to bypass |
| Efficiency | |
| AC Mode | 95% / 95% |
| Battery Mode | 92% |
| Battery Data | |
| Battery Type | 12 V / 7 Ah / 12 V / 9 Ah |
| Electrical Data | |
| Numbers | 16 / 20 |
| Typical Recharge Time | 7 hours recover to 90% capacity / 9 hours recover to 90% capacity |
| Charging Voltage | 218.4 VDC ± 1% / 240 VDC ± 1% |
| Battery | |
| Charging Current (max.) | 1 A ± 10% (Default) / 1 A ± 10% (Default) |
| Communication | |
| Standard RS-232/USB | Supports Windows® Family, Linux and MAC / Supports Windows® Family, Linux and MAC |
| Optional SNMP | Power management from SNMP manager and web browser / Power management from SNMP manager and web browser |
| Mechanical Data | |
| Dimension, D×W×H (mm) | 369 × 190 × 688 / 442 × 190 × 688 |
| Net Weight (kgs) | 55 / 74 |
| Additional Specifications | |
| Weight | 55 / 74 |
| Operating Conditions | |
| Operating Humidity | <95 % RH @ 0- 40°C (Non-condensing) / <95 % RH @ 0- 40°C (Non-condensing) |
| Noise Level | Less than 55dB @1Meter / Less than 55dB @1Meter |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Sudan
| Market | Sudan |
| Grid authority / regulator | Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum |
| Quotation currency | SDG |
| Support hours timezone | Africa/Khartoum |
| Delivery & installation coverage | Khartoum, Omdurman, Port Sudan, Kassala, Nyala |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Sudan that is Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- Advanced DSP control technology: Advanced DSP control technology
- Ultra-wide voltage input range: Ultra-wide voltage input range
- High power density with optimized: High power density with optimized structural design
- Self-diagnostics and hidden fault detection: Self-diagnostics and hidden fault detection
- Green Power Bidirectional Protection: Green Power Bidirectional Protection
Frequently Asked Questions
What are the main performance specifications of the Galleon III UPS?
The Galleon III UPS offers a nominal voltage of 208/220/230/240 VAC with a power factor of ≥ 0.99 at full load. It ensures high efficiency with a THDi of less than 4% at 100% load and provides a pure sinewave output in battery mode.
Is the Galleon III compatible with different battery types and solar panels?
The Galleon III is designed to work seamlessly with various battery types and can be integrated into solar panel systems, making it versatile for different power setups.
What are the physical specifications of the Galleon III UPS?
The physical dimensions and weight of the Galleon III UPS are designed for easy installation and integration into existing systems. However, specific dimensions and weight details should be confirmed with the manufacturer.
What are the installation requirements for the Galleon III UPS?
Installation of the Galleon III UPS requires a stable environment with proper ventilation. It should be installed by a qualified technician to ensure optimal performance and safety.
What warranty is provided with the Galleon III UPS?
Voltronic Power offers a standard warranty for the Galleon III UPS, covering manufacturing defects and ensuring reliable performance. Specific warranty terms should be verified with the supplier.
What certifications does the Galleon III UPS have?
The Galleon III UPS is ROHS certified, ensuring compliance with environmental and safety standards.
What are the operating conditions for the Galleon III UPS?
The Galleon III UPS operates efficiently in a wide range of temperatures and humidity levels, ensuring reliable performance in various environmental conditions.
What are the key features and benefits of the Galleon III UPS?
Key features of the Galleon III UPS include zero transfer time, pure sinewave output, and high overload capacity, providing uninterrupted power and protection for sensitive equipment.