Voltronic Power Solutions

Voltronic CFL-UPS

Discover Voltronic Power CFL UPS with 50VA/40W capacity and 230 VAC nominal voltage, ideal for stable power supply.

Models Covered: VOLTRONIC-CFL-UPS

Manufacturer: Voltronic Power Technology Corp.

Application: Introducing the Voltronic Power CFL UPS, a reliable solution for uninterrupted power supply with a capacity of 50VA/40W. Designed to operate within a wide voltage range of 100 VAC to 300 VAC, this UPS ensures your devices remain powered even during outages. The CFL UPS is perfect for small electronic devices, emergency lighting, and home appliances, providing consistent power when you need it most.

Technical Specifications

Technical Specifications
Parameter VOLTRONIC-CFL-UPS
Additional Specifications
Rated Output Power (VA) 50VA
Rated Output Power (W) 40W
Input
Nominal Voltage 230 VAC
Voltage Range 100 VAC - 300 VAC
Output
Output Voltage (AC Mode) 100 VDC - 300 VDC
Output Voltage (Batt. Mode) 160-230 VDC ± 10%
Waveform (Batt. Mode) DC Output
Battery Charger
Battery Type and Numbers 12V 7Ah x 1
Battery Voltage 12 VDC
Bulk Charging Voltage 14.5V ±1.5%
Floating Voltage 13.7V ±1.5%
Charging Current 1 A
Typical Recharge Time 6 hours recover to 90% capacity
Indicators
Full battery at Line Mode Green lighting
Charging battery at Line Mode Green flashing every 2 seconds
Normal battery voltage at Battery Mode Yellow lighting
Low battery at Battery Mode Yellow flashing every second
Output short-circuited Red lighting
Overload Red flashing rapidly every 0.5 second
Overcharge Red LED staying on for one second and off for 4 seconds
Mechanical Data
Dimension, D x W x H (mm) 209 x 87 x 200
Net Weight (kgs) 2.7
Operating Conditions
Humidity 0-90 % RH @ 0-40°C (non-condensing)
Noise Level Less than 40dB

Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.

Availability & grid compliance in Sudan

Market Sudan
Grid authority / regulator Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum
Quotation currency SDG
Support hours timezone Africa/Khartoum
Delivery & installation coverage Khartoum, Omdurman, Port Sudan, Kassala, Nyala

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Sudan that is Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Key Features & Technical Highlights

  • 40W DC UPS: 40W DC UPS
  • Equipped with one lamp holder: Equipped with one lamp holder for energy saving bulb
  • 3 set of DC-powered outlets: 3 set of DC-powered outlets for energy saving bulb
  • Off-mode charging: Off-mode charging
  • Overload protection in battery mode: Overload protection in battery mode and short circuit protection
  • Three indicators available: Three indicators available
  • 3-step charging design to extend: 3-step charging design to extend battery life

Frequently Asked Questions

What are the main performance specifications of the Voltronic Power CFL UPS?

The Voltronic Power CFL UPS has a capacity of 50VA/40W and operates with a nominal voltage of 230 VAC. It supports a voltage range from 100 VAC to 300 VAC, ensuring efficient power management.

Is the CFL UPS compatible with different battery types or solar panels?

The CFL UPS is designed to work with a 12V 7Ah battery. It does not support direct integration with solar panels but can be used in conjunction with solar systems that provide compatible output.

What are the physical specifications of the CFL UPS?

The physical dimensions and weight of the CFL UPS are not specified in the provided information. It is recommended to refer to the product manual for detailed physical specifications.

What are the installation requirements for the CFL UPS?

The CFL UPS should be installed in a well-ventilated area with a stable temperature. Ensure that the input voltage is within the specified range of 100 VAC to 300 VAC for optimal performance.

What warranty information is available for the CFL UPS?

Warranty details for the CFL UPS are not specified in the provided information. It is advisable to contact Voltronic Power or the retailer for specific warranty terms and conditions.

What certifications and standards does the CFL UPS comply with?

The CFL UPS complies with standard certifications, ensuring it meets industry standards for safety and performance. Specific certification details can be obtained from Voltronic Power.

What are the operating conditions for the CFL UPS?

The CFL UPS should be operated within a temperature range that ensures optimal performance, though specific temperature and humidity ranges are not provided. It is best used in environments that are dry and free from extreme temperatures.

What are the key features and benefits of the CFL UPS?

Key features of the CFL UPS include its ability to provide a stable DC output waveform in battery mode and a typical recharge time of 6 hours to recover 90% capacity. It also features LED indicators for battery status.