Introducing the Voltronic Power CFL UPS, a reliable solution for uninterrupted power supply with a capacity of 50VA/40W. Designed to operate within a wide voltage range of 100 VAC to 300 VAC, this UPS ensures your devices remain powered even during outages.
Technical Specifications
| Parameter | Value |
|---|---|
| General Specifications | |
| Capacity | 50VA/40W |
| Input | |
| Nominal Voltage | 230 VAC |
| Voltage Range | 100 VAC - 300 VAC |
| Output | |
| Output Voltage (AC Mode) | 100 VDC - 300 VDC |
| Output Voltage (Batt. Mode) | 160-230 VDC ± 10% |
| Waveform (Batt. Mode) | DC Output |
| Battery & Charger | |
| Battery Type and Numbers | 12V 7Ah x 1 |
| Battery Voltage | 12 VDC |
| Bulk Charging Voltage | 14.5V ±1.5% |
| Floating Voltage | 13.7V ±1.5% |
| Charging Current | 1 A |
| Typical Recharge Time | 6 hours recover to 90% capacity |
| Indicators | |
| Full battery at Line Mode | Green lighting |
| Charging battery at Line Mode | Green flashing every 2 seconds |
| Normal battery voltage at Battery Mode | Yellow lighting |
| Low battery at Battery Mode | Yellow flashing every second |
| Output short-circuited | Red lighting |
| Overload | Red flashing rapidly every 0.5 second |
| Overcharge | Red LED staying on for one second and off for 4 seconds |
| Mechanical Data | |
| Dimension, D x W x H (mm) | 209 x 87 x 200 |
| Net Weight (kgs) | 2.7 |
| Operating Conditions | |
| Humidity | 0-90 % RH @ 0-40°C (non-condensing) |
| Noise Level | Less than 40dB |
Note: Specifications are based on the official Voltronic Power datasheet. Values may be subject to change; always verify against the latest manufacturer documentation.
Key Features
40W DC UPS
Equipped with one lamp holder for energy saving bulb
3 set of DC-powered outlets for energy saving bulb
Off-mode charging
Overload protection in battery mode and short circuit protection
Three indicators available
3-step charging design to extend battery life
Applications & Use Cases
Typical Applications
- Data centers
- Hospitals and medical facilities
- Banks and financial institutions
- Telecommunications
- Factories and industrial facilities
Regional Installation Notes (United Arab Emirates)
Climate Suitability: Suitable for United Arab Emirates's hot climate with reliable performance at high temperatures.
- Ensure adequate ventilation
- Protection from direct sunlight
- Regular maintenance recommended
Frequently Asked Questions
What are the main performance specifications of the Voltronic Power CFL UPS?
The Voltronic Power CFL UPS has a capacity of 50VA/40W and operates with a nominal voltage of 230 VAC. It supports a voltage range from 100 VAC to 300 VAC, ensuring efficient power management.
Is the CFL UPS compatible with different battery types or solar panels?
The CFL UPS is designed to work with a 12V 7Ah battery. It does not support direct integration with solar panels but can be used in conjunction with solar systems that provide compatible output.
What are the physical specifications of the CFL UPS?
The physical dimensions and weight of the CFL UPS are not specified in the provided information. It is recommended to refer to the product manual for detailed physical specifications.
What are the installation requirements for the CFL UPS?
The CFL UPS should be installed in a well-ventilated area with a stable temperature. Ensure that the input voltage is within the specified range of 100 VAC to 300 VAC for optimal performance.
What warranty information is available for the CFL UPS?
Warranty details for the CFL UPS are not specified in the provided information. It is advisable to contact Voltronic Power or the retailer for specific warranty terms and conditions.
What certifications and standards does the CFL UPS comply with?
The CFL UPS complies with standard certifications, ensuring it meets industry standards for safety and performance. Specific certification details can be obtained from Voltronic Power.
What are the operating conditions for the CFL UPS?
The CFL UPS should be operated within a temperature range that ensures optimal performance, though specific temperature and humidity ranges are not provided. It is best used in environments that are dry and free from extreme temperatures.
What are the key features and benefits of the CFL UPS?
Key features of the CFL UPS include its ability to provide a stable DC output waveform in battery mode and a typical recharge time of 6 hours to recover 90% capacity. It also features LED indicators for battery status.