Voltronic Power AXPERT-MKS-ZERO-LV-1000-12/2000-24/3000-48

The Axpert MKS Zero LV Axpert MKS-ZERO LV 1000-12 is a off-grid solar inverter rated Axpert MKS-ZERO LV 1000-12. Every figure on this page is read from the manu

Models Covered: AXPERT-MKS-ZERO-LV-1000-12, AXPERT-MKS-ZERO-LV-2000-24, AXPERT-MKS-ZERO-LV-3000-48

Manufacturer: Voltronic Power

Application: The Axpert MKS Zero LV Axpert MKS-ZERO LV 1000-12 is a off-grid solar inverter rated Axpert MKS-ZERO LV 1000-12. Every figure on this page is read from the manufacturer's manual for the Axpert MKS Zero LV series.

Download PDF Datasheet WhatsApp Us

Technical Specifications

Technical Specifications
Parameter AXPERT-MKS-ZERO-LV-1000-12AXPERT-MKS-ZERO-LV-2000-24AXPERT-MKS-ZERO-LV-3000-48
PV String Input Data
MPPT Voltage Range 15~115V
Max PV Open-Circuit Voltage 30~115V
Electrical / AC Output Data
Rated AC Power 1000VA/1000W2000VA/2000W3000VA/3000W
Transfer / Switchover Time Oms
AC Frequency Range 46-54 Hz or 56-64 Hz
Input Voltage Range 95-140 VAC
Line Mode Efficiency > 90%
THD / THDi ≤ 10%
AC Voltage Regulation (Battery Mode) 120VAC ± 5%
ECO Mode 98%
Battery Data
Max Solar / PV Charge Current 80A
Max AC Charge Current 60A
Mechanical Data
Dimensions (W×H×D) 295 x 468 x 120 mm
Weight 10.5 kg11.0 kg11.5 kg
Operating Conditions
Operating Temperature -10°C to 50°C
Relative Humidity 5% to 95%
Communication
Communication Interface RS232

Note: Specifications are based on the official Voltronic Power AXPERT-MKS-ZERO-LV-1000-12/2000-24/3000-48 datasheet. Values may be subject to change; always verify against the latest manufacturer documentation before system design and procurement.

Availability & grid compliance in UAE

Market UAE
Grid authority / regulator DEWA, ADDC, SEWA
Quotation currency AED
Support hours timezone Asia/Dubai
Delivery & installation coverage Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in UAE that is DEWA, ADDC, SEWA. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Availability & grid compliance in Oman

Market Oman
Grid authority / regulator Authority for Electricity Regulation Oman
Quotation currency OMR
Support hours timezone Asia/Muscat
Delivery & installation coverage Muscat, Salalah, Sohar

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Oman that is Authority for Electricity Regulation Oman. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.