Voltronic Power AXPERT-VM-III-TWIN-IP52-40A-AXPERT-VM-III-TWIN-IP52-4/6.5K

The Axpert VM III TWIN IP52 40A Axpert VM III TWIN IP52 4.5K is a off-grid solar inverter rated Axpert VM III TWIN IP52 4.5K. Every figure on this page is read

Models Covered: AXPERT-VM-III-TWIN-IP52-40A-AXPERT-VM-III-TWIN-IP52-4.5K, AXPERT-VM-III-TWIN-IP52-40A-AXPERT-VM-III-TWIN-IP52-6.5K

Manufacturer: Voltronic Power

Application: The Axpert VM III TWIN IP52 40A Axpert VM III TWIN IP52 4.5K is a off-grid solar inverter rated Axpert VM III TWIN IP52 4.5K. Every figure on this page is read from the manufacturer's manual for the Axpert VM III TWIN IP52 40A series.

Download PDF Datasheet WhatsApp Us

Technical Specifications

Technical Specifications
Parameter AXPERT-VM-III-TWIN-IP52-40A-AXPERT-VM-III-TWIN-IP52-4.5KAXPERT-VM-III-TWIN-IP52-40A-AXPERT-VM-III-TWIN-IP52-6.5K
PV String Input Data
Max PV Array Power 6000W
Max PV Input Current 40A
Electrical / AC Output Data
Max Efficiency 93%
Rated AC Power 4500VA/4500W
Surge / Peak Power 9000VA13000VA
AC Voltage Regulation (Battery Mode) 230VAC ± 5%
Selectable Voltage Range 170-280 VAC (For Personal Computers)
Battery Data
Max Charge Current 120A
Max Solar / PV Charge Current 120A
Max AC Charge Current 100A
Protection Features
IP Rating IP52
Operating Conditions
Operating Temperature -10°C to 50°C
Relative Humidity 5% to 95%
Storage Temperature Range -15°C to 60°C
Communication
Communication Interface USB/RS232/RS485/WiFi/Dry-contact

Note: Specifications are based on the official Voltronic Power AXPERT-VM-III-TWIN-IP52-40A-AXPERT-VM-III-TWIN-IP52-4/6.5K datasheet. Values may be subject to change; always verify against the latest manufacturer documentation before system design and procurement.

Availability & grid compliance in UAE

Market UAE
Grid authority / regulator DEWA, ADDC, SEWA
Quotation currency AED
Support hours timezone Asia/Dubai
Delivery & installation coverage Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in UAE that is DEWA, ADDC, SEWA. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Availability & grid compliance in Morocco

Market Morocco
Grid authority / regulator ONEE Morocco
Quotation currency MAD
Support hours timezone Africa/Casablanca
Delivery & installation coverage Casablanca, Rabat, Marrakech, Tangier

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Morocco that is ONEE Morocco. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.