Voltronic Power AXPERT-MAX-E-TWIN-11000

The Axpert MAX E TWIN Axpert MAX E TWIN-11000 is a off-grid solar inverter rated Axpert MAX E TWIN-11000. Every figure on this page is read from the manufacture

Models Covered: AXPERT-MAX-E-TWIN-11000

Manufacturer: Voltronic Power

Application: The Axpert MAX E TWIN Axpert MAX E TWIN-11000 is a off-grid solar inverter rated Axpert MAX E TWIN-11000. Every figure on this page is read from the manufacturer's manual for the Axpert MAX E TWIN series.

Download PDF Datasheet WhatsApp Us

Technical Specifications

Technical Specifications
Parameter AXPERT-MAX-E-TWIN-11000
PV String Input Data
Max PV Array Power 11000W
MPPT Voltage Range 90~450 VDC
Electrical / AC Output Data
Max Efficiency 93%
Rated AC Power 11000VA/11000W
Surge / Peak Power 22000VA
Parallel Capability YES, 6 units
AC Voltage Regulation (Battery Mode) 230VAC ±5%
Selectable Voltage Range 170-280 VAC (For Computers)
Standby / Self-Consumption Power <70W
Battery Data
Max Charge Current 150A
Max Solar / PV Charge Current 150A
Max AC Charge Current 150A
Mechanical Data
Dimensions (W×H×D) 432.5 x 553.6 x 147.4 mm
Net Weight 18.4 kg
Operating Conditions
Operating Temperature -10°C to 50°C
Relative Humidity 5% to 95%
Storage Temperature Range -15°C to 60°C
Communication
Communication Interface USB/RS232/RS485/WiFi/Dry-contact

Note: Specifications are based on the official Voltronic Power AXPERT-MAX-E-TWIN-11000 datasheet. Values may be subject to change; always verify against the latest manufacturer documentation before system design and procurement.

Availability & grid compliance in UAE

Market UAE
Grid authority / regulator DEWA, ADDC, SEWA
Quotation currency AED
Support hours timezone Asia/Dubai
Delivery & installation coverage Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in UAE that is DEWA, ADDC, SEWA. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Availability & grid compliance in Lebanon

Market Lebanon
Grid authority / regulator EDL Lebanon
Quotation currency LBP
Support hours timezone Asia/Beirut
Delivery & installation coverage Beirut, Tripoli, Sidon

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Lebanon that is EDL Lebanon. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.