Voltronic Power AXPERT-MAX-II-80000

The Axpert MAX II Axpert MAX II 80000 is a off-grid solar inverter rated Axpert MAX II 80000. Every figure on this page is read from the manufacturer's manual f

Models Covered: AXPERT-MAX-II-80000

Manufacturer: Voltronic Power

Application: The Axpert MAX II Axpert MAX II 80000 is a off-grid solar inverter rated Axpert MAX II 80000. Every figure on this page is read from the manufacturer's manual for the Axpert MAX II series.

Download PDF Datasheet WhatsApp Us

Technical Specifications

Technical Specifications
Parameter AXPERT-MAX-II-80000
PV String Input Data
Max PV Array Power 8000W (4000W x 2)
Nominal DC Voltage 12 VDC ± 5%, 100W
Solar Charger Type MPPT
Electrical / AC Output Data
Surge / Peak Power 16000VA
Transfer / Switchover Time 15 ms (For Personal Computers); 20 ms (For Home Appliances)
Output Waveform Pure sine wave
AC Voltage Regulation (Battery Mode) 230VAC ± 5%
Selectable Voltage Range 170-280 VAC (For Personal Computers); 90-280 VAC (For Home Appliances)
Standby / Self-Consumption Power < 70W
Battery Data
Max Charge Current 150A
Max Solar / PV Charge Current 150A
Floating / Constant Charge Voltage 54 VDC
Max AC Charge Current 120A
Mechanical Data
Dimensions (W×H×D) 158.4 x 502.5 x 1530.8 mm
Net Weight 20 kg
Operating Conditions
Operating Temperature -10°C to 50°C
Relative Humidity 5% to 95% Relative Humidity (Non-condensing)
Storage Temperature Range -15°C to 60°C

Note: Specifications are based on the official Voltronic Power AXPERT-MAX-II-80000 datasheet. Values may be subject to change; always verify against the latest manufacturer documentation before system design and procurement.

Availability & grid compliance in UAE

Market UAE
Grid authority / regulator DEWA, ADDC, SEWA
Quotation currency AED
Support hours timezone Asia/Dubai
Delivery & installation coverage Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in UAE that is DEWA, ADDC, SEWA. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Availability & grid compliance in Jordan

Market Jordan
Grid authority / regulator EMRC Jordan
Quotation currency JOD
Support hours timezone Asia/Amman
Delivery & installation coverage Amman, Zarqa, Irbid

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Jordan that is EMRC Jordan. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.