Voltronic Power AXPERT-MAX-II-6500
The Axpert MAX II Axpert MAX II 6500 is a off-grid solar inverter rated Axpert MAX II 6500. Every figure on this page is read from the manufacturer's manual for
Download PDF Datasheet WhatsApp UsTechnical Specifications
| Parameter | AXPERT-MAX-II-6500 |
|---|---|
| PV String Input Data | |
| Max PV Array Power | 8000W (4000W x 2) |
| Electrical / AC Output Data | |
| Max Efficiency | 91% |
| Rated AC Power | 6500VA/6500W |
| Surge / Peak Power | 13000VA |
| Parallel Capability | YES, 6 units |
| AC Voltage Regulation (Battery Mode) | 120VAC ± 5% |
| Selectable Voltage Range | 90-140 VAC (For Computers); 80-140 VAC (For Home Appliances) |
| Standby / Self-Consumption Power | < 75W |
| Battery Data | |
| Max Charge Current | 120A |
| Max Solar / PV Charge Current | 120A |
| Max AC Charge Current | 120A |
| Mechanical Data | |
| Dimensions (W×H×D) | 503.6 x 530.8 x 158.4 mm |
| Weight | 20.0 kg |
| Operating Conditions | |
| Operating Temperature | -10°C to 50°C |
| Relative Humidity | 5% to 95% |
| Storage Temperature Range | -15°C to 60°C |
| Communication | |
| Communication Interface | USB/RS232/RS485/WiFi/Dry-contact |
Note: Specifications are based on the official Voltronic Power AXPERT-MAX-II-6500 datasheet. Values may be subject to change; always verify against the latest manufacturer documentation before system design and procurement.
Availability & grid compliance in UAE
| Market | UAE |
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Delivery & installation coverage | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in UAE that is DEWA, ADDC, SEWA. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Availability & grid compliance in France
| Market | France |
| Grid authority / regulator | CRE France |
| Quotation currency | EUR |
| Support hours timezone | Europe/Paris |
| Delivery & installation coverage | Paris, Marseille, Lyon, Toulouse |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in France that is CRE France. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.