Voltronic Power AXPERT-WP-TWIN-8KW
The Axpert WP TWIN 8KW is a solar inverter rated 8KW. Every figure on this page is read from the manufacturer's manual for the Axpert WP TWIN series.
Technical Specifications
| Parameter | AXPERT-WP-TWIN-8KW |
|---|---|
| Additional Specifications | |
| Rated Output Power | 8000W |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) |
| Safety Compliance | CE |
| Nominal Input Voltage | 230Vac |
| High Loss Voltage | 280Vac±7V |
| High Loss Return Voltage | 270Vac±7V |
| Max AC Input Voltage | 300Vac |
| Nominal Input Frequency | 50Hz/60Hz (Auto detection) |
| Low Loss Frequency | 40±1Hz |
| Low Loss Return Frequency | 42±1Hz |
| High Loss Frequency | 65±1Hz |
| High Loss Return Frequency | 63±1Hz |
| Output Short Circuit Protection | Line mode: Circuit Breaker Battery mode: Electronic Circuits |
| Max. PV Array Open Circuit Voltage | 500Vdc |
| PV Array MPPT Voltage Range | 90Vdc 450Vdc |
| Max. Input Current | 18A x 2 |
| Start-up Voltage | 80V +/- 5Vdc |
| Max parallel numbers | 6 |
| Parallel communication | CAN |
| Parallel Kit | YES |
| Dimension (D*W*H), mm | 665x 435 x 210 |
| Net Weight, kg | 32 |
| Storage temperature | -15°C~ 60°C |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) |
| Electrical / AC Output Data | |
| Max Efficiency | 93% |
| Surge Capacity | 2* rated power for 5 seconds |
| DC Offset | ≤ 100mV |
| Standby / Self-Consumption Power | <85W |
| Battery Data | |
| High DC Recovery Voltage | 64Vdc |
| High DC Cut-off Voltage | 66Vdc |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Yemen
| Market | Yemen |
| Grid authority / regulator | Public Electricity Corporation (PEC), Ministry of Electricity and Energy |
| Quotation currency | YER |
| Support hours timezone | Asia/Aden |
| Delivery & installation coverage | Sana'a, Aden, Taiz, Al Hudaydah, Mukalla |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Yemen that is Public Electricity Corporation (PEC), Ministry of Electricity and Energy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.