Voltronic Power AXPERT-WP-TWIN-8KW
The Axpert WP TWIN 8KW is a solar inverter rated 8KW. Every figure on this page is read from the manufacturer's manual for the Axpert WP TWIN series.
Technical Specifications
| Parameter | AXPERT-WP-TWIN-8KW |
|---|---|
| Additional Specifications | |
| Rated Output Power | 8000W |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) |
| Safety Compliance | CE |
| Nominal Input Voltage | 230Vac |
| High Loss Voltage | 280Vac±7V |
| High Loss Return Voltage | 270Vac±7V |
| Max AC Input Voltage | 300Vac |
| Nominal Input Frequency | 50Hz/60Hz (Auto detection) |
| Low Loss Frequency | 40±1Hz |
| Low Loss Return Frequency | 42±1Hz |
| High Loss Frequency | 65±1Hz |
| High Loss Return Frequency | 63±1Hz |
| Output Short Circuit Protection | Line mode: Circuit Breaker Battery mode: Electronic Circuits |
| Max. PV Array Open Circuit Voltage | 500Vdc |
| PV Array MPPT Voltage Range | 90Vdc 450Vdc |
| Max. Input Current | 18A x 2 |
| Start-up Voltage | 80V +/- 5Vdc |
| Max parallel numbers | 6 |
| Parallel communication | CAN |
| Parallel Kit | YES |
| Dimension (D*W*H), mm | 665x 435 x 210 |
| Net Weight, kg | 32 |
| Storage temperature | -15°C~ 60°C |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) |
| Electrical / AC Output Data | |
| Max Efficiency | 93% |
| Surge Capacity | 2* rated power for 5 seconds |
| DC Offset | ≤ 100mV |
| Standby / Self-Consumption Power | <85W |
| Battery Data | |
| High DC Recovery Voltage | 64Vdc |
| High DC Cut-off Voltage | 66Vdc |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Sudan
| Market | Sudan |
| Grid authority / regulator | Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum |
| Quotation currency | SDG |
| Support hours timezone | Africa/Khartoum |
| Delivery & installation coverage | Khartoum, Omdurman, Port Sudan, Kassala, Nyala |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Sudan that is Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.