Voltronic AXPERT-KING-II-TWIN/AXPERT-KING-II-TWIN-6.2K/AXPERT-KING-II-TWIN-6K
The Axpert KING II TWIN 6KW is a solar charge controller rated 6KW.
Technical Specifications
| Parameter | AXPERT-KING-II-TWIN-6KW | VOLTRONIC-AXPERT-KING-II-TWIN | AXPERT-KING-II-TWIN-6.2K | AXPERT-KING-II-TWIN-6K |
|---|---|---|---|---|
| Additional Specifications | ||||
| Input Voltage Waveform | Sinusoidal | |||
| Nominal Input Voltage | 230Vac | |||
| Low Loss Voltage | 176Vac±7V | |||
| Low Loss Return Voltage | 186Vac+7V | |||
| High Loss Voltage | 280Vac±7V | |||
| High Loss Return Voltage | 270Vac±7V | |||
| Max AC Input Voltage | 300Vac | |||
| Nominal Input Frequency | 50Hz/60Hz (Auto detection) | |||
| Low Loss Frequency | 46(56)±1Hz | |||
| Low Loss Return Frequency | 46.5(57)±1Hz | |||
| High Loss Frequency | 54(64)±1Hz | |||
| High Loss Return Frequency | 6KW | |||
| Power Factor | >0.98 | |||
| Efficiency (Line Mode) | 93% ( | |||
| Floating Charging Voltage | 54Vdc | |||
| Communication | RS232 and Wi-Fi | |||
| Bypass Mode | 6KW | |||
| Voltage Range | 110-280 VAC | |||
| Output Short Circuit Protection | Line mode: Circuit Breaker Battery mode: Electronic Circuits | |||
| Surge Capacity | 2* rated power for 5 seconds | |||
| Nominal DC Input Voltage | 48Vdc | |||
| No Load Power Consumption | <75W | |||
| Max. PV Array Open Circuit Voltage | 500Vdc | |||
| Safety Certification | CE | |||
| Floating Charge Voltage | 54 VDC | |||
| Maximum PV Array Open Circuit Voltage | 500 VDC | |||
| Maxmum Solar Charge Current | 120A | |||
| AC Output | ||||
| Transfer Time | InverterBypass 4ms | 0 ms | InverterBypass 4ms | InverterBypass 4ms |
| Waveform | Pure sine wave | |||
| PARALLEL CAPABILITY | Up to 9 units | |||
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz | |||
| Time Inverter to Bypass | 4 ms (Typical) | |||
| Battery Input | ||||
| Overcharge Protection | 66Vdc | 66 VDC | 66Vdc | 66Vdc |
| Battery Voltage | 40–66 VDC | |||
| Efficiency | ||||
| Line Mode | 94% | |||
| Battery Mode | 92% | |||
| ECO Mode | 98% | |||
| PV Input | ||||
| Maximum AC Charge Current | 120A | 120A / 120A | 120A | 120A |
| Solar Charger type | MPPT | |||
| Maximum PV Array Power | 6000 W | |||
| MPPT Range @ Operating Voltage | 120 – 430 VDC | |||
| Maximum Solar Charge Current | 120A / 120A | |||
| Operating Conditions | ||||
| Storage Temperature | -15°C~ 60°C | -15°C to 60°C | — | -15°C to 60°C |
| Humidity | 5% to 95% | 5% to 95% Relative Humidity(Non-condensing) | 5% to 95% | 5% to 95% |
| Operating Temperature | -10°C to 50°C | |||
| Electrical Data | ||||
| RATED POWER | — | 6000VA/6000W / 6200VA/6200W | 6200VA/6200W | 6000VA/6000W |
| AC Voltage Regulation (Line&Batt. Mode) | — | 230VAC ± 5% | 230VAC ±5% | 230VAC ±5% |
| Frequency Range (Synchronized Range) | — | 46–54 Hz or 56–64 Hz | 46-54 Hz or 56-64 Hz | 46-54 Hz or 56-64 Hz |
| Harmonic Distortion | — | ≤ 3 % THD (Linear Load); ≤ 5 % THD (Non-linear Load) | ≤3% THD (Linear Load); ≤ 5% THD (Non-linear Load) | ≤3% THD (Linear Load); ≤ 5% THD (Non-linear Load) |
| Communication | ||||
| Communication Interface | — | RS232, USB, Dry contact, WI-FI, RS485 | RS232, USB | RS232, USB |
| Mechanical Data | ||||
| Dimension, D x W x H (mm) | 140 x 295 x 468 | |||
| Net Weight (kgs) | 12 | |||
| Electrical / AC Output Data | ||||
| THDi | ≤ 10% | |||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Yemen
| Market | Yemen |
| Grid authority / regulator | Public Electricity Corporation (PEC), Ministry of Electricity and Energy |
| Quotation currency | YER |
| Support hours timezone | Asia/Aden |
| Delivery & installation coverage | Sana'a, Aden, Taiz, Al Hudaydah, Mukalla |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Yemen that is Public Electricity Corporation (PEC), Ministry of Electricity and Energy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- Dual outputs, for smart load: Dual outputs, for smart load management
- Maximum PV input current increases: Maximum PV input current increases to 27A
- Zero (0ms) transfer time to: Zero (0ms) transfer time to protect mission-critical loads such as servers and ATMs
- High PV input voltage range: High PV input voltage range
- Detachable LCD control module with: Detachable LCD control module with multiple communications
- Selectable high power charging current: Selectable high power charging current
- Built-in Wi-Fi for mobile monitoring: Built-in Wi-Fi for mobile monitoring (App is available)
- Configurable AC/Solar input priority via: Configurable AC/Solar input priority via LCD setting
- Reserved communication port for BMS: Reserved communication port for BMS (RS485 or CAN-BUS)
- USB On-the-Go function: USB On-the-Go function
- Parallel operation up to 9: Parallel operation up to 9 units
Frequently Asked Questions
What are the main performance specifications of the Axpert King II TWIN inverter?
The Axpert King II TWIN inverter has a rated power of 6000VA/6000W. It offers high efficiency with 94% in line mode, 98% in ECO mode, and 92% in battery mode. The AC voltage regulation is 230VAC ± 5%.
Is the Axpert King II TWIN compatible with different battery types and solar panels?
Yes, the inverter is compatible with various battery types, operating at a voltage range of 40–66 VDC. It can also be integrated with solar panels and the grid for hybrid energy solutions.
What are the physical specifications of the Axpert King II TWIN?
The physical dimensions and weight of the Axpert King II TWIN are not specified here. However, it is important to check the product manual for detailed physical specifications and IP rating.
What are the installation requirements for the Axpert King II TWIN?
Installation should be performed by a qualified technician. Ensure proper ventilation and avoid exposure to extreme temperatures or moisture. Refer to the installation manual for detailed instructions.
What warranty is provided with the Axpert King II TWIN?
The Axpert King II TWIN comes with a standard warranty. For specific warranty terms and conditions, please refer to the warranty documentation provided with the product.
What certifications and standards does the Axpert King II TWIN comply with?
The Axpert King II TWIN complies with standard certifications, ensuring it meets industry standards for safety and performance. Specific certification details can be found in the product documentation.
What are the operating conditions for the Axpert King II TWIN?
The inverter is designed to operate efficiently within a specific temperature and humidity range. For optimal performance, avoid extreme environmental conditions. Refer to the product manual for detailed operating conditions.
What are the key features and benefits of the Axpert King II TWIN?
Key features include parallel capability of up to 9 units, pure sine wave output, and a fast transfer time of 0 ms. These features ensure reliable and efficient power management for various applications.