Voltronic Power AXPERT-SE-3000-24/AXPERT-MKS-II-SE-5000-48
The Axpert SE 3000-24 is an off-grid solar inverter rated Axpert SE 3000-24.
Technical Specifications
| Parameter | AXPERT-SE-3000-24 | AXPERT-SE-AXPERT-MKS-II-SE-5000-48 |
|---|---|---|
| Electrical / AC Output Data | ||
| Rated AC Power | 3000VA/3000W | |
| Selectable Voltage Range | 90-280 VAC (For Home Appliances) | |
| AC Voltage Regulation (Battery Mode) | 230VAC ± 5% | |
| Max Efficiency | 93% | |
| Overload Capability | 105% 130% load 10 sec ; ≥130% load 5 sec | 110%-150% load 10 sec; ≥150% load 5 sec |
| PV String Input Data | ||
| Max PV Array Power | 4000W | |
| Additional Specifications | ||
| Maximum Charge Current | 80A | |
| Maxmum Solar Charge Current | 80A | |
| Transfer Time | 10 ms (For Personal Computers) ; 20 ms (For Home Appliances) | |
| Waveform | Pure sine wave | |
| Floating Charge Voltage | 27 VDC | |
| Solar Charger Type | MPPT | |
| Maximum PV Array Open Circuit Voltage | 500 VDC | |
| Communication | ||
| Communication Interface | USB and RS232 | |
| Battery Data | ||
| Max AC Charge Current | 60A | 80A |
| Operating Conditions | ||
| Relative Humidity | 5% to 95% | |
| Operating Temperature | -10°C to 50°C | |
| Storage Temperature Range | -15°C to 60°C | |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Sudan
| Market | Sudan |
| Grid authority / regulator | Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum |
| Quotation currency | SDG |
| Support hours timezone | Africa/Khartoum |
| Delivery & installation coverage | Khartoum, Omdurman, Port Sudan, Kassala, Nyala |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Sudan that is Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.