Voltronic APEX-LINE-INTERACTIVE-UPS
Discover the Voltronic Power Apex Line Interactive UPS with voltage options of 110/120 or 220/230/240 VAC and auto-sensing frequency.
Technical Specifications
| Parameter | VOLTRONIC-APEX-LINE-INTERACTIVE-UPS |
|---|---|
| Electrical Data | |
| Voltage | 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 220/230/240 VAC |
| Voltage Range | 81-145 VAC / 162-290 VAC / 81-145 VAC / 162-290 VAC / 81-145 VAC / 162-290 VAC / 81-145 VAC / 162-290 VAC / 81-145 VAC / 162-290 VAC / 81-145 VAC / 162-290 VAC / 162-290 VAC |
| Output Voltage | 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 220/230/240 VAC |
| Input | |
| Frequency Range | 60/50 Hz (Auto sensing) |
| Output | |
| AC Voltage Regulation (Batt. Mode) | ± 10% |
| Frequency Range (Batt. Mode) | 50 Hz or 60 Hz ± 1 Hz |
| Transfer Time | Typical 2-6 ms |
| Waveform (Batt. Mode) | Simulated Sinewave |
| Battery | |
| Typical Recharge Time | 4-6 hours recover to 90% capacity |
| Indicators | |
| LCD Model | Input voltage, output voltage, battery capacity, load level and UPS status |
| LED Mode | AC Mode: Green lighting / Battery Mode: Green flashing / Fault: N/A / Fault: N/A / Fault: N/A / Fault: N/A / Fault: N/A |
| Alarm | |
| Low Battery | Sounding every second |
| Overload | Sounding every 0.5 second |
| Fault | Continuously sounding |
| Physical | |
| LCD Dimension, D×W×H (mm) | 300 x 101 x 142 / 320 x 130 x 182 / 390 x 147 x 205 / 390 x 147 x 205 / 390 x 147 x 205 / 390 x 147 x 205 / 390 x 147 x 205 |
| LED Dimension, D×W×H (mm) | 279 x 101 x 142 / 320 x 130 x 182 / 390 x 147 x 205 / 390 x 147 x 205 / 390 x 147 x 205 / 390 x 147 x 205 / 390 x 147 x 205 |
| Physical Data | |
| Net Weight (kgs) | 3.7 / 4.4 / 5.0 / 7.8 / 10.4 / 10.6 / 15.1 |
| Additional Specifications | |
| Weight | 3.7 / 4.4 / 5.0 / 7.8 / 10.4 / 10.6 / 15.1 |
| Protection Features | |
| Full Protection | Overload, discharge, and overcharge protection |
| Operating Conditions | |
| Humidity | 0-90 % RH @ 0- 40°C (Non-condensing) |
| Noise Level | Less than 40dB / Less than 45dB / Less than 45dB / Less than 45dB / Less than 45dB / Less than 45dB / Less than 45dB |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Sudan
| Market | Sudan |
| Grid authority / regulator | Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum |
| Quotation currency | SDG |
| Support hours timezone | Africa/Khartoum |
| Delivery & installation coverage | Khartoum, Omdurman, Port Sudan, Kassala, Nyala |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Sudan that is Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 400VA, 600VA, 800VA, 1KVA, 1.5KVA,: 400VA, 600VA, 800VA, 1KVA, 1.5KVA, 2KVA, 3KVA line interactive UPS
- Touch screen LCD to display: Touch screen LCD to display UPS information circularly (option)
- Compact size: Compact size
- Boost and buck AVR for: Boost and buck AVR for voltage stabilization
- Auto restart while AC is: Auto restart while AC is recovering
- Off-mode charging: Off-mode charging
- Cold start function: Cold start function
- Generator compatible (option): Generator compatible (option)
- No load shutdown in battery: No load shutdown in battery mode for 800VA and below models
- Optional HID Power Device USB: Optional HID Power Device USB port
Frequently Asked Questions
What are the main performance specifications of the Apex Line Interactive UPS?
The Apex Line Interactive UPS offers a voltage range of 81-145 VAC or 162-290 VAC and operates at a frequency range of 60/50 Hz with auto sensing. It provides an output voltage of 110/120 VAC or 220/230/240 VAC with an AC voltage regulation of ± 10% in battery mode.
Is the Apex Line Interactive UPS compatible with different battery types or solar panels?
The UPS uses a 12 V/4.5 Ah battery and is designed primarily for standard grid applications. It does not support direct connection to solar panels without additional equipment.
What are the physical specifications of the Apex Line Interactive UPS?
The specific dimensions and weight of the Apex Line Interactive UPS are not detailed in the provided specifications. Please refer to the product manual or contact Voltronic Power for precise information.
What are the installation requirements for the Apex Line Interactive UPS?
The UPS should be installed in a well-ventilated area, away from direct sunlight and moisture. Ensure that the input voltage matches the UPS's voltage specifications for optimal performance.
What warranty information is available for the Apex Line Interactive UPS?
Voltronic Power typically offers a standard warranty for their UPS products. For specific warranty details, please check the product documentation or contact customer support.
What certifications and standards does the Apex Line Interactive UPS meet?
The Apex Line Interactive UPS complies with standard certifications, ensuring reliability and safety in its operation. For detailed certification information, refer to the product documentation.
What are the operating conditions for the Apex Line Interactive UPS?
The UPS is designed to operate efficiently within a standard temperature and humidity range. For specific operating conditions, please consult the product manual.
What are the key features and benefits of the Apex Line Interactive UPS?
Key features include simulated sinewave output in battery mode, a typical transfer time of 2-6 ms, and comprehensive protection against overload, discharge, and overcharge. The LCD model provides real-time information on input voltage, output voltage, battery capacity, load level, and UPS status.