Voltronic Winner Pro+

The Winner Pro+ by Voltronic Power is a state-of-the-art Online UPS designed to deliver reliable power protection. With a nominal voltage range of 110-240VAC and a frequency range of 40-70 Hz, it ensures consistent performance and stability for your critical systems.

Models Covered: Winner Pro+ 1K (L), Winner Pro+ 2K (L), Winner Pro+ 3K (L), Winner Pro+ 6K (L), Winner Pro+ 10K (L), Winner Pro+ 1KR (L), Winner Pro+ 2KR (L), Winner Pro+ 3KR (L), Winner Pro+ 6KR (L), Winner Pro+ 10KR (L)

Manufacturer: Voltronic Power Technology Corp.

Application: Ideal for data centers, telecommunications, and critical IT infrastructure, the Winner Pro+ provides seamless power backup and voltage regulation to protect sensitive equipment.

Single Phase Online UPS True double-conversion Input power factor correction Output power factor 0.9 Wide input voltage range Converter mode available
Download PDF Datasheet WhatsApp Us

Technical Specifications

Technical Specifications
Parameter Winner Pro+ 1K (L)Winner Pro+ 2K (L)Winner Pro+ 3K (L)Winner Pro+ 6K (L)Winner Pro+ 10K (L)
AC Input
Nominal Voltage 110/115/120/127VAC or 208/220/230/240VAC110/115/120/127VAC or 208/220/230/240VAC110/115/120/127VAC or 208/220/230/240VAC208/220/230/240VAC208/220/230/240VAC
Input Voltage Range 60-145 VAC or 120-300 VAC (Based on load at 50%)60-145 VAC or 120-300 VAC (Based on load at 50%)60-145 VAC or 120-300 VAC (Based on load at 50%)110-300 VAC (Based on load at 50%)176-300 VAC (Based on load at 100%)
Frequency Range 40 Hz ~ 70 Hz40 Hz ~ 70 Hz40 Hz ~ 70 Hz46~54 Hz or 56~64 Hz46~54 Hz or 56~64 Hz
Power Factor > 0.99 @ Nominal Voltage (100% load)
AC Output
Output Voltage 110/115/120/127VAC or 208/220/230/240VAC110/115/120/127VAC or 208/220/230/240VAC110/115/120/127VAC or 208/220/230/240VAC208/220/230/240VAC208/220/230/240VAC
Voltage Regulation ± 1%
Frequency Range (Synchronized Range) 47 ~ 53 Hz or 57 ~ 63 Hz47 ~ 53 Hz or 57 ~ 63 Hz47 ~ 53 Hz or 57 ~ 63 Hz46~54 Hz or 56~64 Hz46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode) 50 Hz or 60Hz ± 0.5%50 Hz or 60Hz ± 0.5%50 Hz or 60Hz ± 0.5%50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1
Harmonic Distortion ≤ 3 % THD (Linear Load) ≤ 6 % THD (Non-linear Load)≤ 3 % THD (Linear Load) ≤ 6 % THD (Non-linear Load)≤ 3 % THD (Linear Load) ≤ 6 % THD (Non-linear Load)≤ 3 % THD (Linear Load) ≤ 5 % THD (Non-linear Load)≤ 3 % THD (Linear Load) ≤ 5 % THD (Non-linear Load)
Transfer Time 4 ms (Typical)4 ms (Typical)4 ms (Typical)ZeroZero
Waveform (Batt. Mode) Pure Sinewave
Efficiency
AC Mode 88%89%90%92%93%
Battery Mode 83%87%88%90%91%
Battery
Battery Type 12 V / 9 Ah
Numbers 23468
Standard Model Typical Recharge Time 4 hours recover to 90% capacity4 hours recover to 90% capacity4 hours recover to 90% capacity9 hours recover to 90% capacity9 hours recover to 90% capacity
Charging Current (max.) 1 A1 A1 A1 A/2 A1 A/2 A
Charging Voltage 27.4VDC ± 1%41.0VDC ± 1%54.7 VDC ± 1%82.1 VDC ± 1% 218.4 VDC ± 1%273VDC ± 1% 218.4 VDC ± 1% 273VDC ± 1%
Mechanical Data
Dimension, D x W x H (mm) 282 x 145 x 397282 x 145 x 397282 x 145 x 397421 x 190 x 318442 x 190 x 318
Net Weight (kgs) 9.811.41726.227.6
Operating Conditions
Humidity 20-90 % RH @ 0-40°C (Non-condensing)20-90 % RH @ 0-40°C (Non-condensing)20-90 % RH @ 0-40°C (Non-condensing)0-95% RH @ 0-50°C (Non-condensing)0-95% RH @ 0-40°C (Non-condensing)
Noise Level Less than 50dB @ 1 MeterLess than 50dB @ 1 MeterLess than 50dB @ 1 MeterLess than 55dB @ 1 MeterLess than 58dB @ 1 Meter
Communication
Smart RS-232 / USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser

Note: Specifications are based on the official Voltronic Power datasheet. Values may be subject to change; always verify against the latest manufacturer documentation.

Key Features

True double-conversion

Microprocessor control optimizes reliability

Input power factor correction

Output power factor 0.9

Wide input voltage range

Converter mode available

ECO mode for energy saving

Adjustable battery numbers

Applications & Use Cases

Typical Applications

  • Data centers
  • Hospitals and medical facilities
  • Banks and financial institutions
  • Telecommunications
  • Factories and industrial facilities

Regional Installation Notes (Qatar)

Climate Suitability: Suitable for Qatar's hot climate with reliable performance at high temperatures.

  • Ensure adequate ventilation
  • Protection from direct sunlight
  • Regular maintenance recommended

Frequently Asked Questions

What are the main performance specifications of the Winner Pro+?

The Winner Pro+ offers a high efficiency of 88% in AC mode and 83% in battery mode. It supports a nominal voltage range of 110/115/120/127VAC or 208/220/230/240VAC with a power factor greater than 0.99 at nominal voltage and full load.

Is the Winner Pro+ compatible with different battery types?

Yes, the Winner Pro+ is compatible with 12 V / 9 Ah batteries. It is designed to work efficiently with this battery type to ensure optimal performance.

What are the physical specifications of the Winner Pro+?

The physical dimensions and weight of the Winner Pro+ are not specified in the provided details. However, it is designed to be compact and suitable for various installation environments.

What are the installation requirements for the Winner Pro+?

The installation of the Winner Pro+ requires a stable power source within the specified input voltage range of 60-145 VAC or 120-300 VAC. Ensure proper ventilation and adherence to safety standards during installation.

What warranty does the Winner Pro+ come with?

The Winner Pro+ comes with a standard warranty, which typically covers manufacturing defects and performance issues. Specific warranty terms should be confirmed with the retailer or manufacturer.

What certifications and standards does the Winner Pro+ meet?

The Winner Pro+ meets standard certifications, ensuring compliance with industry standards for safety and performance. Specific certifications can be confirmed with the manufacturer.

What are the operating conditions for the Winner Pro+?

The Winner Pro+ is designed to operate efficiently within a frequency range of 40 Hz to 70 Hz. It should be used in environments with controlled temperature and humidity to ensure optimal performance.

What are the key features and benefits of the Winner Pro+?

Key features of the Winner Pro+ include its pure sinewave output in battery mode, a fast transfer time of 4 ms, and a low harmonic distortion of ≤ 3% THD for linear loads. These features ensure reliable and efficient power supply.