Technical Specifications

Technical Specifications
Parameter AXPERT-VM-III-TWIN-PV40A-VM-III-6000-TWIN-PV-8000
PV String Input Data
Max PV Array Power 5600W
Max PV Input Current 40A
Electrical / AC Output Data
Max Efficiency 93%
Rated AC Power 4000VA/4000W
Surge / Peak Power 12000VA
AC Voltage Regulation (Battery Mode) 230VAC ±10%
Selectable Voltage Range 170-280 VAC (For Personal Computers)
Battery Data
Max Charge Current 120A
Max Solar / PV Charge Current 120A
Max AC Charge Current 100A
Operating Conditions
Operating Temperature -10°C to 50°C
Relative Humidity 5% to 95%
Storage Temperature Range -15°C to 60°C
Communication
Communication Interface USB/RS232/RS485/WiFi/Dry-contact

Note: Specifications are based on the official Voltronic Power AXPERT-VM-III-TWIN-PV40A-VM-III-6000-TWIN-PV-8000 datasheet. Values may be subject to change; always verify against the latest manufacturer documentation before system design and procurement.

Availability & grid compliance in UAE

Market UAE
Grid authority / regulator DEWA, ADDC, SEWA
Quotation currency AED
Support hours timezone Asia/Dubai
Delivery & installation coverage Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in UAE that is DEWA, ADDC, SEWA. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Availability & grid compliance in Qatar

Market Qatar
Grid authority / regulator Kahramaa
Quotation currency QAR
Support hours timezone Asia/Qatar
Delivery & installation coverage Doha, Al Wakrah, Al Khor

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Qatar that is Kahramaa. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.