| Parameter | INFINISOLAR-SUPER-4KW |
|---|---|
| PV String Input Data | |
| Max PV Input Power | 5000 W |
| Max PV / DC Voltage | 580 VDC |
| MPPT Voltage Range | 120 VDC 500 VDC ~ |
| MPPT Voltage Range at Full Load | 280 VDC~500 VDC |
| Start-up Voltage | 116 VDC / 150 VDC |
| Max PV Short-Circuit Current | 25 A |
| Nominal DC Voltage | 360 VDC |
| Electrical / AC Output Data | |
| Max AC Output Power | 4000VA/4000W |
| AC Output Voltage | 230 VAC |
| Grid / AC Frequency | 50 Hz / 60 Hz |
| Input Voltage Range | 170 280 VAC - |
| Max Conversion Efficiency (DC/AC) | 91% |
| Nominal Output Current | 17.4 A |
| AC Input | 4000VA/4000W |
| AC Start-up Voltage | 120-140 VAC |
| Adjustable Power Factor Range | 0.9 lead – 0.9 lag - |
| Auto Restart Voltage | 180 VAC |
| Inrush Current | 17.4 A / 20ms |
| Max AC Input Current | 18 A |
| Battery Data | |
| Working DC Voltage Range | 100 VDC~500 VDC |
| Protection Features | |
| Maximum Output Fault Current | 52 A / 1ms |
| Max. Output Overcurrent Protection | 52 A |
| Mechanical Data | |
| Dimensions (W×H×D) | 438 x 535 x 117 mm |
| Weight | 16.2 kg |
Note: Specifications are based on the official Voltronic Power INFINISOLAR-SUPER-4KW datasheet. Values may be subject to change; always verify against the latest manufacturer documentation before system design and procurement.
Availability & grid compliance in UAE
| Market | UAE |
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Delivery & installation coverage | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in UAE that is DEWA, ADDC, SEWA. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Availability & grid compliance in Morocco
| Market | Morocco |
| Grid authority / regulator | ONEE Morocco |
| Quotation currency | MAD |
| Support hours timezone | Africa/Casablanca |
| Delivery & installation coverage | Casablanca, Rabat, Marrakech, Tangier |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Morocco that is ONEE Morocco. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.