Voltronic Power VOLTRONIC-VM-III-6000-TWIN-PV-8000

Discover the VM III-6000 TWIN-PV 8000 inverter by Voltronic Power with 230 VAC voltage and 12000VA surge power for optimal performance.

Models Covered: VOLTRONIC-VM-III-6000-TWIN-PV-8000

Manufacturer: Voltronic Power Technology Corp.

Application: The Axpert VM III TWIN-PV inverter by Voltronic Power is engineered for superior energy conversion with its 230 VAC voltage and auto-sensing frequency range of 50/60 Hz. Designed to handle up to 12000VA surge power, it ensures reliable performance in demanding environments. Ideal for residential and commercial solar power systems, the Axpert VM III TWIN-PV inverter efficiently manages energy conversion, ensuring stable power supply even during peak loads.

Download PDF Datasheet WhatsApp Us

Technical Specifications

Technical Specifications
Parameter VOLTRONIC-VM-III-6000-TWIN-PV-8000
PV String Input Data
Max PV Array Power 8000W
Max PV Input Current 40A
MPPT Voltage Range 60 – 450 VDC
Max PV Open-Circuit Voltage 500 VDC
Solar Charger Type MPPT
Electrical / AC Output Data
Max Efficiency 93%
Surge / Peak Power 12000VA
Transfer / Switchover Time 20 ms
AC Frequency Range 50/60 Hz (Auto)
Nominal AC Voltage 230 VAC
Output Waveform Pure sine wave
AC Voltage Regulation (Battery Mode) 230VAC ± 10%
Selectable Voltage Range 90-280 VAC
Battery Data
Battery Voltage 48 VDC
Max Charge Current 120A
Max Solar / PV Charge Current 120A
Floating / Constant Charge Voltage 54 VDC
Max AC Charge Current 100A
Protection Features
Overcharge Protection 63 VDC
Mechanical Data
Dimensions (W×H×D) 300 x 435 x 115 mm
Net Weight 10 kg
Weight 10 kg
Operating Conditions
Operating Temperature -10°C to 50°C
Relative Humidity 5% to 95% Relative Humidity (Non-condensing)
Storage Temperature Range -15°C to 60°C
Communication
Communication Interface USB/RS232/RS485/WiFi/Dry-contact

Note: Specifications are based on the official Voltronic Power VOLTRONIC-VM-III-6000-TWIN-PV-8000 datasheet. Values may be subject to change; always verify against the latest manufacturer documentation before system design and procurement.

Availability & grid compliance in UAE

Market UAE
Grid authority / regulator DEWA, ADDC, SEWA
Quotation currency AED
Support hours timezone Asia/Dubai
Delivery & installation coverage Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in UAE that is DEWA, ADDC, SEWA. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Key Features & Technical Highlights

  • Increased PV power to 8000W: Increased PV power to 5600W and 8000W based on model
  • Detachable LCD control module with: Detachable LCD control module with various communications
  • Maximum PV input current 40A: Maximum PV input current 40A
  • Dual output for smart load: Dual output for smart load management
  • Built-in WiFi for mobile monitoring: Built-in WiFi for mobile monitoring and OTA firmware upgrade
  • Supports USB On-the-Go function: Supports USB On-the-Go function
  • Built-in BMS communication port: Built-in BMS communication port
  • Built-in meter calibration for optimized: Built-in meter calibration for optimized system operation
  • Battery independent design: Battery independent design
  • Built-in anti-dust kit: Built-in anti-dust kit

Frequently Asked Questions

What are the main performance specifications of the Axpert VM III TWIN-PV inverter?

The Axpert VM III TWIN-PV inverter offers a peak efficiency of 93% and a surge power capacity of 12000VA. It operates at a voltage of 230 VAC with a selectable range of 170-280 VAC and supports both 50 Hz and 60 Hz frequencies.

Is the Axpert VM III TWIN-PV compatible with different battery types and solar panels?

Yes, the inverter is compatible with 48 VDC battery systems and supports MPPT solar chargers with a maximum PV array power of 8000W. It can handle a wide MPP range of 60 – 450 VDC.

What are the physical specifications of the Axpert VM III TWIN-PV inverter?

The specific dimensions and weight of the Axpert VM III TWIN-PV inverter are not detailed in the provided specifications. Please refer to the product manual for detailed physical specifications.

What are the installation requirements for the Axpert VM III TWIN-PV inverter?

Installation should be performed by a qualified technician, ensuring proper ventilation and adherence to local electrical codes. The inverter should be installed in a dry, dust-free environment.

What warranty does the Axpert VM III TWIN-PV inverter come with?

The warranty details for the Axpert VM III TWIN-PV inverter are not specified in the provided information. Please contact Voltronic Power or your distributor for warranty terms.

What certifications and standards does the Axpert VM III TWIN-PV inverter meet?

The Axpert VM III TWIN-PV inverter complies with standard certifications, ensuring reliable performance and safety. Specific certifications are not listed in the provided details.

What are the operating conditions for the Axpert VM III TWIN-PV inverter?

The inverter is designed to operate efficiently in a range of environmental conditions. However, specific temperature and humidity ranges are not provided in the specifications.

What are the key features and benefits of the Axpert VM III TWIN-PV inverter?

Key features include pure sine wave output, a fast transfer time of 10 ms, and robust overcharge protection at 33 VDC. These features ensure efficient and reliable power conversion.

Availability & grid compliance in Lebanon

Market Lebanon
Grid authority / regulator EDL Lebanon
Quotation currency LBP
Support hours timezone Asia/Beirut
Delivery & installation coverage Beirut, Tripoli, Sidon

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Lebanon that is EDL Lebanon. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.