Voltronic Power AXPERT-KING-II-TWIN-6.2KW
The Axpert KING II TWIN 6.2KW is a solar charge controller rated 6.2KW. Every figure on this page is read from the manufacturer's manual for the Axpert KING II
Download PDF Datasheet WhatsApp UsTechnical Specifications
| Parameter | AXPERT-KING-II-TWIN-6.2KW |
|---|---|
| Electrical / AC Output Data | |
| Transfer / Switchover Time | InverterBypass 4ms |
| AC Input Voltage | 230Vac |
| Grid / AC Frequency | 50Hz/60Hz (Auto detection) |
| Line Mode Efficiency | 93% ( |
| Output Waveform | Sinusoidal |
| High Line Disconnect | 280Vac±7V |
| High Line Re-connect | 270Vac±7V |
| Low Line Disconnect | 176Vac±7V |
| Low Line Re-connect | 186Vac+7V |
| Max AC Input Voltage | 300Vac |
| Power Factor | >0.98 |
| High Line Frequency Disconnect | 54(64)±1Hz |
| High Line Frequency Re-connect | 6.2KW Hz |
| Low Line Frequency Disconnect | 46(56)±1Hz |
| Low Line Frequency Re-connect | 46.5(57)±1Hz |
| Battery Data | |
| Floating / Constant Charge Voltage | 54Vdc |
| Protection Features | |
| Overcharge Protection | Charging Algorithm |
| Operating Conditions | |
| Relative Humidity | 5% to 95% |
| Storage Temperature Range | -15°C~ 60°C |
| Communication | |
| Communication Interface | RS232 and Wi-Fi |
Note: Specifications are based on the official Voltronic Power AXPERT-KING-II-TWIN-6.2KW datasheet. Values may be subject to change; always verify against the latest manufacturer documentation before system design and procurement.
Availability & grid compliance in UAE
| Market | UAE |
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Delivery & installation coverage | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in UAE that is DEWA, ADDC, SEWA. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Availability & grid compliance in France
| Market | France |
| Grid authority / regulator | CRE France |
| Quotation currency | EUR |
| Support hours timezone | Europe/Paris |
| Delivery & installation coverage | Paris, Marseille, Lyon, Toulouse |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in France that is CRE France. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.