Voltronic Power AXPERT-WP-1.5/3/4/6KW
The Axpert WP Axpert WP 1.5KW is a hybrid solar inverter rated Axpert WP 1.5KW. Every figure on this page is read from the manufacturer's manual for the Axpert
Download PDF Datasheet WhatsApp UsTechnical Specifications
| Parameter | AXPERT-WP-1.5KW | AXPERT-WP-3KW | AXPERT-WP-4KW | AXPERT-WP-6KW |
|---|---|---|---|---|
| PV String Input Data | ||||
| Max PV Array Power | 2400W | 3600W | 6000W | 8000W |
| Max PV Input Current | 18A x 1 | |||
| MPPT Voltage Range | 90~450 VDC | |||
| Start-up Voltage | 70VDC | 120VDC | 120VDC | 120VDC |
| Nominal DC Voltage | 240VDC | 320VDC | 320VDC | 320VDC |
| Electrical / AC Output Data | ||||
| Max Efficiency | 91% | |||
| Rated AC Power | 1500VA/1500W | 3000VA/3000W | 4000VA/4000W | 6000VA/6000W |
| Surge / Peak Power | 3000VA | 6000VA | 8000VA | 12000VA |
| AC Voltage Regulation (Battery Mode) | 230VAC ±5% | |||
| Selectable Voltage Range | 170-280 VAC (For Personal Computers) | |||
| Protection Features | ||||
| IP Rating | IP65 | |||
| Mechanical Data | ||||
| Net Weight | 10.5 kg | |||
| Operating Conditions | ||||
| Operating Temperature | -10°C to 50°C | |||
| Relative Humidity | 5% to 95% | |||
| Storage Temperature Range | -15°C to 60°C | |||
| Communication | ||||
| Communication Interface | RS232/RS485(BMS)/WiFi | |||
| Display | 2.5' Graphical LCD | |||
Note: Specifications are based on the official Voltronic Power AXPERT-WP-1.5/3/4/6KW datasheet. Values may be subject to change; always verify against the latest manufacturer documentation before system design and procurement.
Availability & grid compliance in UAE
| Market | UAE |
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Delivery & installation coverage | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in UAE that is DEWA, ADDC, SEWA. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Availability & grid compliance in Egypt
| Market | Egypt |
| Grid authority / regulator | EgyptERA, NREA |
| Quotation currency | EGP |
| Support hours timezone | Africa/Cairo |
| Delivery & installation coverage | Cairo, Alexandria, Giza, Aswan |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Egypt that is EgyptERA, NREA. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.