Voltronic Winner Pro
The Winner Pro by Voltronic Power is an advanced Online UPS designed to deliver exceptional power protection with a nominal voltage range of 110/115/120/127VAC or 208/220/230/240VAC. With a wide input voltage range and precise voltage regulation, it ensures your critical systems remain operational under any condition.
Technical Specifications
| Parameter | Winner Pro 1K (L) | Winner Pro 2K (L) | Winner Pro 3K (L) | Winner Pro 6K (L) | Winner Pro 10K (L) |
|---|---|---|---|---|---|
| AC Input | |||||
| Nominal Voltage | 110/115/120/127VAC or 208/220/230/240VAC | 110/115/120/127VAC or 208/220/230/240VAC | 110/115/120/127VAC or 208/220/230/240VAC | 208/220/230/240VAC | 208/220/230/240VAC |
| Input Voltage Range | 85-140VAC or 160-280VAC (Based on load at 100%) | 85-140VAC or 160-280VAC (Based on load at 100%) | 85-140VAC or 160-280VAC (Based on load at 100%) | 176-300VAC (Based on load at 100%) | 176-300VAC (Based on load at 100%) |
| Frequency Range | 40 Hz ~ 70 Hz | 40 Hz ~ 70 Hz | 40 Hz ~ 70 Hz | 46~54 Hz or 56~64 Hz | 46~54 Hz or 56~64 Hz |
| Power Factor | > 0.99 @ Nominal Voltage (100% load) | ||||
| AC Output | |||||
| Output Voltage | 110/115/120/127VAC or 208/220/230/240VAC | 110/115/120/127VAC or 208/220/230/240VAC | 110/115/120/127VAC or 208/220/230/240VAC | 208/220/230/240VAC | 208/220/230/240VAC |
| Voltage Regulation | ± 1% | ||||
| Frequency Range (Synchronized Range) | 47 ~ 53 Hz or 57 ~ 63 Hz | 47 ~ 53 Hz or 57 ~ 63 Hz | 47 ~ 53 Hz or 57 ~ 63 Hz | 46~54 Hz or 56~64 Hz | 46~54 Hz or 56~64 Hz |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz | 50 Hz or 60Hz ± 0.1 Hz | 50 Hz or 60Hz ± 0.1 Hz |
| Current Crest Ratio | 3:1 | ||||
| Harmonic Distortion | ≤ 3 % THD (Linear Load) | ≤ 3 % THD (Linear Load) | ≤ 3 % THD (Linear Load) | ≤ 5 % THD (Non-linear Load) | ≤ 5 % THD (Non-linear Load) |
| Transfer Time AC Mode to Battery Mode | Zero | ||||
| Time Interval to Bypass | 4 ms (Typical) | 4 ms (Typical) | 4 ms (Typical) | Zero | Zero |
| Waveform (Batt. Mode) | Pure Sinewave | ||||
| Efficiency | |||||
| AC Mode | 88% | 89% | 90% | 92% | 93% |
| Battery Mode | 83% | 87% | 88% | 90% | 91% |
| Battery | |||||
| Battery Type | 12 V / 9 Ah | ||||
| Numbers | 2 | 2 | 3 | 16 | 20 |
| Standard Model Typical Recharge Time | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | 9 hours recover to 90% capacity | 9 hours recover to 90% capacity |
| Charging Current (max.) | 1 A | 1 A | 1 A | 1 A / 2 A | 1 A / 2 A |
| Charging Voltage | 27.4VDC ± 1% | 54.7 VDC ± 1% | 82.1 VDC ± 1% | 218.4 VDC ± 1% | 273 VDC ± 1% |
| Long-run Model Numbers | 2 | 3 | 4 | 8 | 16 |
| Long-run Model Charging Current (max.) | 1A/2A/4A/6A (Adjustable) | 1A/2A/4A/6A (Adjustable) | 1A/2A/4A/6A (Adjustable) | 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries) | 1A/2A/4A/6A (Adjustable, 6A is only available for 20pcs batteries) |
| Charging Voltage | 27.4VDC ± 1% | 54.7 VDC ± 1% | 82.1 VDC ± 1% | 273 VDC ± 1% (Based on 20pcs batteries) | 273 VDC ± 1% (Based on 20pcs batteries) |
| Physical | |||||
| Dimension D x W x H (mm) | 282 x 145 x 220 | 397 x 145 x 220 | 421 x 190 x 318 | 369 x 190 x 688 | 442 x 190 x 688 |
| Net Weight (kgs) | 9.8 | 17 | 27.6 | 62 | 76 |
| Operating Conditions | |||||
| Humidity | 20-90 % RH @ 0- 40°C (Non-condensing) | 20-90 % RH @ 0- 40°C (Non-condensing) | 20-90 % RH @ 0- 40°C (Non-condensing) | 0-95% RH @ 0-50°C (Non-condensing) | 0-95% RH @ 0-50°C (Non-condensing) |
| Noise Level | Less than 50dB @ 1 Meter | Less than 50dB @ 1 Meter | Less than 50dB @ 1 Meter | Less than 55dB @ 1 Meter | Less than 58dB @ 1 Meter |
| Communication | |||||
| Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC | ||||
| Optional SNMP | Power management from SNMP manager and web browser | ||||
Note: Specifications are based on the official Voltronic Power datasheet. Values may be subject to change; always verify against the latest manufacturer documentation.
Key Features
True double-conversion
Output power factor 0.8
Wide input voltage (110V – 300V)
Converter mode available
ECO mode for energy saving (Only available for 1-3KVA)
Generator compatible
Adjustable battery number only available for 6K and up models
Smart SNMP works well with either USB or RS-232 together
Applications & Use Cases
Typical Applications
- Data centers
- Hospitals and medical facilities
- Banks and financial institutions
- Telecommunications
- Factories and industrial facilities
Regional Installation Notes (United Arab Emirates)
Climate Suitability: Suitable for United Arab Emirates's hot climate with reliable performance at high temperatures.
- Ensure adequate ventilation
- Protection from direct sunlight
- Regular maintenance recommended
Frequently Asked Questions
What are the main performance specifications of the Winner Pro?
The Winner Pro offers high efficiency with 88% in AC mode and 83% in battery mode. It supports a nominal voltage range of 110/115/120/127VAC or 208/220/230/240VAC, ensuring stable power delivery with a voltage regulation of ± 1%.
Is the Winner Pro compatible with different battery types or solar panels?
The Winner Pro is designed to work seamlessly with various battery types. However, for solar panel compatibility, additional equipment such as a solar charge controller may be required.
What are the physical specifications of the Winner Pro?
The physical dimensions and weight of the Winner Pro are not specified in the provided details. For precise information, please refer to the product manual or contact Voltronic Power support.
What are the installation requirements for the Winner Pro?
The Winner Pro should be installed in a well-ventilated area with a stable temperature and humidity level. Ensure that the input voltage range is within 85-140VAC or 160-280VAC based on the load.
What warranty does the Winner Pro come with?
Voltronic Power typically offers a standard warranty on their products. For specific warranty details on the Winner Pro, please consult the product documentation or contact customer service.
What certifications and standards does the Winner Pro adhere to?
The Winner Pro complies with standard certifications, ensuring reliability and safety in its operation. For detailed certification information, refer to the product specifications or contact Voltronic Power.
What are the operating conditions for the Winner Pro?
The Winner Pro operates efficiently within a frequency range of 40 Hz to 70 Hz. It is important to maintain a controlled environment to ensure optimal performance.
What are the key features and benefits of the Winner Pro?
Key features of the Winner Pro include zero transfer time from AC to battery mode, a pure sinewave output in battery mode, and a high power factor of > 0.99 at nominal voltage, providing reliable and efficient power management.