Voltronic Scudo
Introducing the Scudo UPS by Voltronic Power, a reliable solution for uninterrupted power supply. With a voltage range of 180-270 VAC and precise voltage regulation, it ensures your devices remain protected and operational.
Technical Specifications
| Parameter | Scudo 400 | Scudo 600 |
|---|---|---|
| Input | ||
| Voltage | 220/230/240 VAC | 220/230/240 VAC |
| Acceptable Voltage Range | 180 - 270 VAC | 180 - 270 VAC |
| Frequency | 50 Hz | 50 Hz |
| Output | ||
| Output Voltage | 220/230/240 VAC | 220/230/240 VAC |
| Voltage Regulation (Batt. Mode) | ± 10% | ± 10% |
| Frequency Range (Batt. Mode) | 50Hz ± 1 Hz | 50Hz ± 1 Hz |
| Transfer Time (Typical) | 2-6 ms | 2-6 ms |
| Waveform (Batt. Mode) | Simulated Sinewave | |
| Battery | ||
| Battery Type & Number | 12 V / 4.5 Ah x 1 | 12 V / 5 Ah x 1 |
| Typical Recharge Time | 8 hours recover to 90% capacity | |
| Physical | ||
| Dimension, D x W x H (mm) | 166 x 161 x 89.2 | 166 x 161 x 89.2 |
| Net Weight (kgs) | 2.25 | 2.56 |
| Operating Conditions | ||
| Humidity | 0-90 % | |
| Operating Temperature | 0- 40°C (non-condensing) | |
| Management | ||
| Smart USB (Option) | N/A | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC |
Note: Specifications are based on the official Voltronic Power datasheet. Values may be subject to change; always verify against the latest manufacturer documentation.
Key Features
Compact size with local receptacles for easy use
Excellent microprocessor control guarantees high reliability
Auto restart while AC is recovering
Simulated sine wave output
Cold start function
Simple and easy installation & operation
Applications & Use Cases
Typical Applications
- Data centers
- Hospitals and medical facilities
- Banks and financial institutions
- Telecommunications
- Factories and industrial facilities
Regional Installation Notes (United Arab Emirates)
Climate Suitability: Suitable for United Arab Emirates's hot climate with reliable performance at high temperatures.
- Ensure adequate ventilation
- Protection from direct sunlight
- Regular maintenance recommended
Frequently Asked Questions
What are the main performance specifications of the Voltronic Power Scudo UPS?
The Scudo UPS operates at a voltage of 220/230/240 VAC with an acceptable voltage range of 180 - 270 VAC. It has a frequency of 50 Hz and provides an output voltage of 220/230/240 VAC with a voltage regulation of ± 10% in battery mode.
Is the Scudo UPS compatible with different battery types or solar panels?
The Scudo UPS uses a 12 V / 4.5 Ah battery. It is not specifically designed for direct integration with solar panels or other battery types without additional equipment.
What are the physical specifications of the Scudo UPS?
The dimensions of the Scudo UPS are 166 x 161 x 89.2 mm, and it has a net weight of 2.25 kg. It does not have an IP rating, indicating it is not specifically rated for dust or water resistance.
What are the installation requirements for the Scudo UPS?
The Scudo UPS should be installed in an environment with a temperature range of 0-40°C and humidity levels between 0-90% (non-condensing). Ensure proper ventilation and avoid placing it in direct sunlight.
What warranty information is available for the Scudo UPS?
The warranty details for the Scudo UPS are typically provided by the retailer or distributor. It is advisable to check with the point of purchase for specific warranty terms and conditions.
What certifications and standards does the Scudo UPS comply with?
The Scudo UPS complies with standard certifications, ensuring it meets industry safety and performance standards. Specific certification details can be obtained from the manufacturer.
What are the operating conditions for the Scudo UPS?
The Scudo UPS operates efficiently within a temperature range of 0-40°C and can handle humidity levels from 0-90% without condensation.
What are the key features and benefits of the Scudo UPS?
Key features of the Scudo UPS include its simulated sinewave output in battery mode, a quick transfer time of 2-6 ms, and a typical recharge time of 8 hours to recover 90% capacity, making it reliable for power backup needs.